PedSafety 906-0034 WiAAPS and WiAAPS Wave User Guide
- June 6, 2024
- PedSafety
Table of Contents
PedSafety 906-0034 WiAAPS and WiAAPS Wave
Product Specifications:
- Product Name: WiAPB & WiAPB Wave
- Power Input: 12VDC or 16VAC (NOT polarity dependent)
- Communication: Wireless
- Antenna: Traffic Control Cabinet Antenna
Product Usage Instructions
Using WiAPC and Termination Board to Provide Power to WiAPBs:
- Mount the Traffic Control Cabinet Antenna on the top or side of the cabinet with a direct line of sight to the intersection where WiAPBs are located.
- Connect WiAPC to the Termination Board to provide 16VAC power.
- Use termination board slot #1 for WiAPB 1, slot #2 for WiAPB 2, and so on for all WiAPBs.
- Connect WiAPBs to the Termination Board for power.
Using SPI in the Pedestrian Signal Head to Provide Power to WiAPBs:
- For 120VAC intersections, use SPI in the Pedestrian Signal Head to power WiAPBs.
- Ensure terminals of the SPI are connected to the same terminals on the WiAPB Base Station.
- For 48VDC intersections, use a different SPI than for 120VAC intersections.
Cabinet Wiring:
- Follow the DB25 APC Input Cable wiring instructions for 120V installations in the cabinet.
- Mount the Antenna on top of the cabinet.
Frequently Asked Questions (FAQ):
-
Q: Can I install the WiAPB upside down?
A: Warranty is void if the WiAPB is installed upside down. Ensure correct installation orientation. -
Q: Are the power connections polarity dependent for WiAPBs?
-
A: No, the power connections for WiAPBs are not polarity dependent. Follow the provided wiring instructions.
WiAAPS & WiAAPS Wave Wiring Quick Guide
Using WiAPC and Termination Board to Provide Power to WiAPBs
Traffic Control Cabinet (WiAPC/Termination board powers WiAPBs from inside the cabinet)
- WiAPC places calls to the traffic control cabinet.
- 9-pin cable needs to be installed from the WiAPC to the terminals of the PED CALLS in the cabinet (9-pin cable included).
- Utilizes the existing or new field wires from cabinet to WiAPBs (for power only).
- Connect the field wires from the cabinet to the Termination Board.
- Termination Board: It is recommended to use termination board slot #1 for WiAPB ”1”, slot #2 for WiAPB “2”, and so on for all the WiAPBs.
SCAN ME:
User Manual Installation Manual
-
WiAPB & WiAPB Wave (warranty void if the WiAPB is installed upside down)
-
WiAPB Base Station (enlarged view of the terminal block on the front)
Using SPI in the Pedestrian Signal Head to Provide Power to WiAPBs
- DO NOT set the SPI on the bottom of the pedestrian signal head! Terminals of the SPI must be connected to the same terminals on the base station.
- Note: 48VDC intersections require a different SPI than 120VAC intersections.
Traffic Control Cabinet (no field wires required to power the WiAPBs)
-
Mount the Antenna on the exterior of the cabinet pointed towards WiAPBs in the intersection.
-
WiAPC places calls to the traffic control cabinet.
-
9-pin cable needs to be installed from the WiAPC to the terminals of the PED CALLS in the cabinet (9-pin cable included).
-
25-pin cable needs to be installed from the WiAPC to the ped head outputs in the cabinet.
-
For cabinets with limited shelf space a WiAPC rack can be ordered separately and installed to mount the WiAPC to an interior wall.
-
WiAPB & WiAPB Wave
(warranty void if the WiAPB is installed upside down) -
WiAPB Base Station (enlarged view of the terminal block on the front)
-
WiAPB wiring connections: 12VDC or 16VDC (NOT polarity dependent)
Cabinet Wiring
Recommended Setup
For complete documentation visit : https://www.pedsafety.com/product- guides-and-manuals/
- ©PedSafety 2024
- PedSafety Tech Support : 208-345-7459