PedSafety 906-0035 Wireless Advanced Accessible Pedestrian System WiAAPS User Manual
- June 6, 2024
- PedSafety
Table of Contents
PedSafety 906-0035 Wireless Advanced Accessible Pedestrian System WiAAPS
User Manual
Last edited: 19 February 2021
This document is copyright © 19 February 2021 by Dick Campbell Company. All rights reserved.
No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission from Campbell Company.
All copyright, confidential information, patents, design rights and all other
intellectual property rights of whatsoever nature contained herein are and
shall remain the sole and exclusive property of Campbell Company. The
information furnished herein is believed to
be accurate and reliable.
However, no responsibility is assumed by Campbell Company for its use, or for any infringements of patents or other rights of third parties resulting from its use.
The Dick Campbell Company name and Campbell Company logo are trademarks or registered trademarks of Campbell Company.
All other trademarks are the property of their respective owners
Revision History
Revision| Revised By| Date
A| Brad| 10/19/17
B| Brad – Revised to incorporate firmware/webpage changes| 1/29/18
C| Travis – Updated to 5.0 WiAPB plus Wave features| 2/5/21
| |
| |
| |
| |
Firmware and Software Versions
Component| Version
APC Firmware| VER:WiAAPS:1.2
APB Firmware| V(Wi) 3.4
APB Bootloader| V (Wi) 3.2
Introduction
Purpose of this Document
The purpose of the document is to describe the operation of the Wireless Advanced Accessible Pedestrian System (WiAAPS). This document does not cover the installation of the WiAAPS.
Additional Information
- See the WiAAPS Installation Guide for installation instructions.
- Reference the PedSafety Intersection Planning Sheet for location specific information.
- See the WiAAPS Installation Quick Guide for a brief graphical installation guide.
- See the Guardian/WiAAPS Base Station Mounting Template for an easy to use hole pattern for mounting APBs.
- These documents are available on the PedSafety website www.pedsafety.com
Contact Information
The first line of contact should be the distributor that the system was purchased from. If you are unable to contact the distributor, contact PedSafety Tech Support directly at 208-345-7459 option 2.
Overview
Product Overview
The WiAAPS is an Accessible Pedestrian System (APS) based on network communications. Communication from the traffic controller cabinet to the pedestrian station is done wirelessly. Power for the pedestrian stations can be provided via 2 wires running from the Advanced Pedestrian Coordinator (APC), which resides in the cabinet, or from an alternate source (solar powered or PedSafety’s Signal Power Interface (SPI). In many cases, the two conductors for power are already at the intersection from the previous pedestrian detector system.
The WiAAPS uses a web browser-based interface to manage and monitor the system. This web browser can be viewed on any device with a network connection to the APC. Desktop computers, laptops, and even handheld devices can connect and operate the system as long as they share a network connection.
The WiAAPS provides all of the standard features for an APS as defined by the MUTCD as well as additional features based on local specifications. A locator tone tells a pedestrian that the crossing is equipped with APS and where it can be found. An extended press provides specific crossing information and access to additional functions. The audible walk tone or message is accompanied by a vibro-tactile indication during the visual walk display. Optional clearance phase indications may provide additional information to the pedestrian where appropriate.
Each WiAAPS is pre-configured at the factory based on the documentation provided by the customer. Configuring the WiAAPS can be done entirely through the APC management webpage, so the customer can re-configure the system as needed. In addition, audio files and operating firmware can be updated directly on an APB through a USB connection.
Features
- Capable of using existing pedestrian field wiring to provide power to the push button stations reducing costs in retrofit installations
- Ethernet access for network/remote configuration
- All configurable settings available over network via web browser including audio message upload
- Time of day functions including nighttime audio volumes
- Pedestrian call count data
- Independent volumes for locator and non-locator audio messages
- Independent station volumes
- Automatic Gain Control (AGC) available for all audio messages
- Accepts audio messages in WAV format
- Audio messages and station configuration backed up on the APC enables quick recovery after a station knock-down
- Clearance interval options including beaconing and audible countdown
- Available with touchless “Wave” active infrared sensor.
Components
There are three primary components to the WiAAPS; the WiAPC, a Termination Board, and one or more Wireless Advanced Pedestrian Buttons (WiAPB).
The WiAPC is the center point of the WiAAPS. It provides both power and pedestrian signal information to all of the WiAPBs. The WiAPC is also the point at which the system is configured. The WiAPC is installed in the traffic controller cabinet. It connects to the 120VAC load switch outputs for the pedestrian signals and the low voltage pedestrian call inputs.
The termination board is installed in the traffic controller cabinet with the WiAPC. It provides a convenient place to land all the power connections to the WiAPBs. The termination board also provides current-limiting protection to each field connection. If alternate power is provided to the WiAPBs, the termination board is not required.
The WiAPB is the point of interaction with the pedestrian.
WiAPB “Wave”
The WiAPB “Wave” feature provides pedestrians a secondary, no-contact form of actuation that protects against the spread of germs and viruses. The WiAPB “Wave” uses active infrared to detect the presence of a pedestrian’s hand typically 1 – 6 inches away from the device. This distance can be adjusted to increase the detection range to typically 1 – 9 inches or decrease the detection range to typically 1 – 3 inches from the device. The “Wave” sensor detection sensitivity can be adjusted so the device actuates with slower or faster hand movements.
The “Wave” sensor works independently from the physical piezo driven push button on the APB and can be turned off if requested. The “Wave” sensor can detect various materials and skin tones to provide a non-exclusive form of actuation for all pedestrians. The sensor resides directly below the physical piezo push button.
Contact PedSafety Tech Support at 208-345-7459 option 2 if the sensor settings need to be changed.
Audio Messages
The WiAAPS comes fully programmed with audio files from the factory but we
give you the option to create your own custom messages in a simple .wav format
that can be easily uploaded
via the APC network connection. Second languages, gender narrative, and
special percussive tones can be easily created, uploaded, and saved via System
Configuration.
Accessing the Utility
To make changes and view the WiAAPS utility, simply plug an Ethernet cable
into the Ethernet port on the front of the APC. Then connect the Ethernet
cable into your laptop. Launch a web browser such as Google Chrome and type in
the APC IP address into the
address bar. (See Below)
Figure 1 Webpage Address bar
You will see the following screen pop up looking for credentials. Default user name: admin Password: password.
Figure 2 Authentication Page
The Webpage has several tabs with different functions. These tabs are:
The Status tab gives an overview of the system.
The APC Settings tab sets the APC configuration, including intersection
information
The Station Settings tab allows for individual station settings to be adjusted
The Station Setup tab allows for new APBs to be connected wirelessly to the
APC.
The Audio Files tab allows for audio files to be added or changed.
The Time tab allows for the time to be adjusted.
The Network tab allows for changes to the APC IP address.
The Log Files tab is where log files are located
The APC Links tab allows for all APC’s IP addresses to be stored
The Advanced tab is where advanced settings can be found.
The Log out tab logs you out of the system.
The functions on these tabs are defined on the following pages.
Status Tab
The Pedestrian Signal Status shows the current state of the system
configuration and the status of each of the connected APBs.
APC Settings
This tab is where the APC configuration is set, including intersection information
Active Stations – allows for a station to be set to active (On) or non-active
(Off)
Intersection Identification
The intersection identification can be found here:
- Location:
- Intersection:
- CC#
- PO #
- An Intersection image can be selected here and then click “Submit Intersection Identification” to update APC
The APC can be set to normal operation (120V I/O Mode) or test (Simulator Mode). The simulator mode allows for the APC and APBs to be tested without being connected to the traffic controller.
Station Settings Tab
Setting station IDs and individual station configuration is done on this tab.
Station ID – allows for the stations to be assigned a specific station ID by using the station’s MAC address, or change which station is assigned to a specific station ID. Utilizing the Station Identity function allows for the station to audibly identify its assigned station ID.
Please consult PedSafety Technical Support prior to using the Reboot, Bootloader or Reset Radio functionality.
All active stations will be shown in this tab. The following settings can be changed:
-
Phase and Sync Call
-
Station Mode
- MUTCD – allows the Stations to perform the assigned functions in accordance with MUTCD and the configuration created (utilized while in operation at the intersection)
- SET ID Mode – allows the stations to accept the setting or changing of the station’s ID
- Audio Mode – allows the stations to accept the setting or changing of the stations audio files
-
Station Walk Timeout
-
Station Button Time
- Extended Press Time: Time in (ms) the contacts will closed to the traffic controller to signify an extended press was made.
-
Button Vibration Time and Intensity
-
Station Audio Timing Set
- Locator Tone Interval: The number of seconds between Locator Tones
- Repeated Acknowledgement: The number of seconds between repeats of the Acknowledgment message. (0 means the message will not be repeated)
-
Station Active Infrared Sensor Configuration
- Wave settings can be adjusted to detect a pedestrian’s hand from a typical distance of 3, 6, or 9 inches.
- IR on and IR off settings can be used to adjust how long the sensor needs to place a call.
- Please contact PedSafety Tech Support at 208-345-7459 option 2 before adjusting any IR Sensor settings.
-
Station Daytime Locator Tone volume
-
Station Daytime all other messages volume (Daytime NON Locator Volume)
-
Station Time of Day. Note: the APC will update the APB time of day clock automatically once per week.
-
Station Night Mode Start and End Time
-
Station Night Mode Locator Tone volume
-
Station Night Mode all other messages volume (Nighttime NON-Locator Volume)
This tab also has certain wireless communication diagnostic information
- Signal strength from stations to APC
- Signal strength from station to station and APC
- Wireless transmission diagnostic data
Station Setup Tab
Adding stations is done on this tab.
The MAC address for the APB can be entered manually or chosen from a search list.
- To search for the APB wirelessly, it must be powered on. Then click on “Search for Stations” button. This list will show all available APB stations. It will note whether or not the APB has been previously connected to that APC. Verify that you have the correct address for the station you want to add before making the selection.
- To enter the MAC address manually, enter the 64-bit address in the “Add Radio MAC” fields. This can be done by typing the address, or pasting it from another file. Click on “Add Radio”.
Station/Firmware update – allows for a firmware update to be applied to the station
Audio Files Tab
The Audio Files tab allows for audio files to be uploaded to individual stations.
a. The first step is to add sound files to the APC. Choose files from the
list, or upload your own files. Click Choose File, select the specific file,
then click “Save to APC.”
b. On the Station Settings tab, set the APBs to Audio Mode.
c. On the Audio Files tab, click on “Go to Audio File Transfer Mode”. This
will take the APBs out of service during the audio file transfer.
d. Files can be sent one at a time to a single station, one file to multiple
stations, or multiple files to some or all of the APBs at one time.
e. The “Play Audio on Stations” function allows review of the messages
programmed on the APB if the APC is set to the Audio File Transfer Mode and
the APB is set to the Audio Mode (set on the “Station Settings” tab).
f. On the Stations Settings Tab, change the APBs back to MUTCD Mode.
g. When finished transferring all the necessary audio files, click on “Go back
to Intersection APC Mode” to reboot the stations and return the intersection
to normal operation.
Time Tab
The Time tab is used for setting up the Real-Time clock
There are three ways of setting the time:
a. Manually enter the time.
b. NTP enable (to get the current time from the internet). Note: the APC must
be able to access the network and an IP address must be entered in the NTP
server box.
c. Click the “Sync with PC time” option
Once the time options are chosen click “Save APC Time”. This will set the time, but also log you out of the webpage. You will need to log back in to continue.
Network Tab
In order to remotely communicate with the APC, the IP address must be set up.
Before changing settings consult you IT Department. Also, remember that the IP
address is how access is granted to the webpage. If the IP address is changed
document it. If the IP address is lost, hold the B1 Button on front of APC and
boot (turn on the unit). The IP address will be reset to the default. See
Accessing the Webpage (paragraph 4.1)
Log Files Tab
There are three sets of logs to be viewed: System log, Event log, and APB log.
- System logging reports changes made to the system.
- Event logging reports any conflicts and/or loss of station communication
- APB log reports ped call counts for each APB. Graphs are available that show history by week, month, and year for each APB.
APC Links Tab
APC links tab will keep track of all the APC’s on your network on one APC.
-
Make sure the network APC is viewable on the network.
-
Enter a Name or the location of the network APC
-
Type the IP address of the network APC in the URL box
a. Example: 192.168.1.101 -
Click APC box
-
Click Add
Advanced Tab
The Reboot button will do a software reboot. This must be done to set time and
IP address for the APC.
Additional users can be created by clicking on the “Create User” link.
Change password: click on edit user: This will reset the password on the WiAAPS webpage (Remember what you changed it to! Mark it on Intersection Planning Sheet and store in cabinet Doc Sleeve.)
Any changes to the advanced configuration section settings should only be done at the direction of Campbell Company. Please contact Campbell Company Technical Assistance before proceeding.
- Intersection Status Scan Interval (ms): How often the I/O is read.
- Station Update Interval (ms): How often the buttons receive an update.
- Display Update Interval (ms): How often the Front panel display is updated.
- Display timeout (ms): Time before the front panel display times out (shuts off)
- Wire map: The wire mapping can be changed
a. Walk input: Able to choose phase assignment of pins by color code.
b. Don’t walk Input: Able to choose phase assignment of pins by color code.
c. Call output: Able to choose what Pin/wire will place a call on a certain phase.
Settings for the wireless radios can be changed to create a unique configuration for each intersection. Click on “Go to Wireless Network Set Up Mode”.
Appendix A: Acronyms, Abbreviations & Definitions
Term | Meaning |
---|---|
Accessible Pedestrian Signal (APS) | A device that communicates information |
about pedestrian timing in a non-visual format such as audible tones, verbal
messages, and/or vibrating surfaces (MUTCD)
Actuated operation| A type of traffic control signal operation in which some
or all signal phases are operated on the basis of actuation (MUTCD)
Audible Beaconing| Use of sound source to provide directional orientation and
alignment information.
Automatic Gain Control (AGC)| An APS volume control that is automatically
responsive to ambient (background) sound.
Base Station| Fully integrated APS station that contains the Micro-controller,
push button, speaker, sign mounting.
Crosswalk| Any portion of a roadway at an intersection or elsewhere distinctly
indicated for pedestrian crossing by lines or other marking on the surface
(MUTCD)
DHCP| Dynamic Host Configuration Protocol
Night Mode| Ability to change audio volumes by time of day
Phase| Cycles assigned to a specified movement
References
- Pedestrian Safety Products | Campbell Company of Idaho
- Pedestrian Safety Products | Campbell Company of Idaho
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>