PedSafety 906-0025 Guardian and Guardian Wave User Guide

June 7, 2024
PedSafety

PedSafety 906-0025 Guardian and Guardian Wave

Specifications:

  • Product Name: Guardian & Guardian Wave
  • Power Supply: 120VAC or 48VDC
  • Cable: 18 Gauge 4 Conductor Shielded Cable
  • Interface: SPI (Signal Power Interface)
  • Compatibility: Traffic Control Cabinet
  • USB Port: For settings, configurations, and data collection

PedSafety-906-0025-Guardian-and-Guardian-Wave-fig-1

Product Usage Instructions:

  • Wiring Quick Guide:
    Ensure the SPI is not set on the bottom of the pedestrian signal head. Connect the SPI terminals to the corresponding terminals on the base station.

  • Power Supply:
    Use either a 120VAC or 48VDC power supply based on the intersection requirements.

  • Cable Connection:
    Utilize an 18 Gauge 4 Conductor Shielded Cable for the low voltage connection. Field wires are necessary for intersections not in recall.

  • USB Port:
    Access settings, configurations, and data collection through the USB port using PedConnex. Download PedConnex from www.pedsafety.com.

  • Installation:
    Ensure the Guardian is not installed upside down to avoid voiding the warranty.

FAQ:

Q: Can I use any power supply for the Guardian?
A : No, you must use either a 120VAC or 48VDC power supply depending on the intersection requirements.

Q: How do I access settings and data collection?
A : Connect a PC or Android device to the Guardian’s USB port using PedConnex downloaded from www.pedsafety.com.