NEO Coolcam Z-wave Intelligent Wireless Siren Alarm User Manual

June 5, 2024
NEO

SIREN ALARM
User Manual
Thank you for your support!

Please read the user manual carefully before operating the device.
Please keep the user manual for future reference.

Product Introduction

The siren alarm is an intelligent device that can be controlled remotely by radiofrequency. The siren alarm sends messages via a Z-Wave network to a Z-Wave controller. In the Z-Wave network communication, the siren alarm can be connected to any Z-Wave controller.
In different countries or areas, the radio frequency may be different.
In the communication between the siren alarm and Z-Wave controller, the siren alarm can both send and receive messages to/from the Z-Wave controller. When the code button of the siren alarm is pressed, it will send a message to the Z-Wave controller and the Z-Wave controller can display the on/off status of the siren alarm. When the siren alarm receives messages from the Z-Wave controller, the siren alarm will be triggered. The siren alarm is battery- powered, small, and easy to install.
When the siren alarm is triggered, the LED light will flash and the alarm will sound at the same time. The sound is not lower than 90 decibels.

Technical Parameters

  • Power supply: 2x CR123A

  • Battery life: ~ 1 year

  • Radio Protocol: Z-Wave

  • Compatible with: Z-Wave 300 series and 500 series

  • Radio Frequency: 868.4 MHz EU; 908.4 MHz US

  • Wireless range: up to 70 m outdoor, up to 50 m indoor

  • Power consumption: 2 W

  • Max. current: 35 mA (in radio transmitter mode)
    500 mA (siren on and max volume)

  • Sounds: 10 music tunes can be selected

  • Sound intensity: > 90 dB

  • Operating temperature: 0 – 40 °C

  • Storage temperature: 0 – 60 °C

  • Size (D x W x H): 70 x 68 x 31 mm

Technical Information

  • Easy installation on a wall or any surface
  •  When an alarm is triggered, the siren sounds and LED light flashes
  • When other sensors are triggered, the siren alarm can associate with these sensors through a Z-Wave network
  • The siren alarm can be controlled remotely via a mobile phone app
  • Compatible with any Z-Wave network

Product Configuration

Items List

Siren alarm 1 piece
Batteries CR123A 2 pieces
Screw / Screw stopper 3 pieces each
Sticker (double-side adhesive tape) 1 piece
User manual 1 piece

Installation Steps

  • Siren alarm Installation
  •  Battery Installation

Siren alarm Installation

Option One
Open the bottom of the siren alarm and fix it with screws.

Option Two
Fix the siren alarm with the sticker (double-side adhesive tape)

Battery Installation

|
---|---
Open the siren alarm| Install the batteries
|
Close the siren alarm| Installation example

Battery Usage Tips
The battery life of the siren alarm is approximately 1 year. The current battery level can be displayed in the Z-Wave controller. A red LED means the battery needs replacing, and an app would receive a message “power level low, please replace the battery” from the controller.
NOTE: The siren alarm is battery-powered. Please use batteries in the correct way to avoid explosion. Dispose of batteries properly. For handling batteries please refer to environmental laws.

Tips

  1. Try to avoid the installation of the siren alarm in noisy places.
  2. Try to install the siren alarm somewhere easy to find.
  3. Try to avoid the installation in a ventilated position as the effect of the siren alarm can be affected.
  4. Do not install it in a wet place to prevent the siren alarm from being damaged.
  5. When the siren alarms, it will sound and the LED will flash red.
  6. Association allows for direct communication between Z-Wave network devices. The controller does not take part in such communication. Using this mechanism, the siren alarm can communicate with other devices even when the controller is damaged.

The status of the LED

Color LED Display Status Description
Red Blink 5 times (1s Interval) Power-on but not added in a Z-Wave network
Blink 5 times (0.5s Interval) After pressing the code button 3 times to

add/remove the siren to/from a Z-Wave network or to send node info
Blink 5 times (0.3s Interval)| Power on and already added in a Z-Wave network
Blink 1 time| After pressing the code button for a long time, when resetting to default settings
Turn on with the rotation| Alarm on

Add the siren alarm to a Z-Wave network
The siren alarm can be included in a Z-Wave network by using the code button.

  1. Open the siren alarm and insert the batteries. Please do not operate the code button within the first 20 s after inserting the batteries. Make sure the device is located within the direct range of the Z-Wave controller.
  2. Set the controller into the Add (inclusion) mode (refer to the controller user manual).
  3. Press the code button of the siren alarm quickly 3 times and it will enter the Add (inclusion) mode. The LED flashes red 5 times on and off alternately.
  4. The siren alarm will be detected and included in the Z-Wave network.
  5. Wait for the controller to configure the siren alarm.

Remove the siren alarm from the Z-Wave Network
The siren alarm can be removed from the Z-Wave network by using the
code button.

  1. Open the siren alarm and make sure it is powered on. Make sure the device is located within the direct range of the Z-Wave controller.
  2. Set the controller into the Remove (exclusion) mode (refer to the controller user manual).
  3. Press the code button of the siren alarm quickly 3 times and it will enter the Remove (exclusion) mode. The LED flashes red 5 times on and off alternately.
  4. Wait for the controller to remove (delete) the siren alarm.

Restore the siren alarm to factory default settings
The reset procedure will delete all information from the Z-Wave network and on the Z-Wave controller and restore the siren alarm to factory default settings.

  1. Open the siren alarm and make sure it is powered on.
  2. Make sure the device is located within the direct range of the controller.
  3. Press and hold the code button for 10-15 s. The LED flashes red 5 times on and off alternately.
  4. Release the button.

NOTE: During the process of resetting please make sure the siren alarm is powered all the time.

Associations
(Association Command Class Version 2)
The siren alarm supports 3 groups. Each group supports max 5 associated nodes. It can identify some Z-Wave notification sensors such as motion sensors, door/window sensors, water leakage sensors, smoke sensors,s and so on. If these sensors associate the siren alarm with their lifeline group or another group that supports NOTIFICATION_REPORT, the siren alarm can play different music when the sensor is triggered.

GROUP 1 is a lifeline service assigned to the siren alarm status. It enables the siren alarm to send reports and readings to the Z-Wave controller whenever the siren alarm is triggered.
This group supports:
– NOTIFICATION_REPORT
– BATTERY_REPORT
– SWITCH_BINARY_REPORT
– DEVICE_RESET_LOCALLY_NOTIFICATION

GROUP 2 allows for sending the Switch Binary Report to associated devices in this group. This group supports:
– SWITCH_BINARY_REPORT

GROUP 3 allows for sending a notification to associated devices in this group. This group supports:
– NOTIFICATION_REPORT

NOTE: Association allows for direct communication between Z-Wave network devices. The controller does not take part in such communication.

Advanced Configuration

  1. Configure Alarm Music Volume
    This parameter defines the output volume when the siren is playing alarm music. The volume is divided into 3 steps, low (set to ‘1’), middle (set to ‘2’), and high (set to ‘3’).
    The default value is ‘3’. Parameter Number| Size| Available settings| Default
    ---|---|---|---
    1| 1| 1 ~ 3| 3
  2. Configure Alarm Music Duration Time
    This parameter defines the alarm music duration time when the siren receives an alarm sensor notification or an alarm command from the controller. The duration time is divided into 5 steps, siren off (set to ‘0’), 30 seconds (set to ‘1’), 1 minute (set to ‘2’), 5 minutes (set to ‘3’), and siren always on until battery is dead (set to ‘255’). The default
    value is ‘2’.
Parameter Number Size Available settings Default
2 1 0 ~ 3, 255 2
  1. Configure Door Bell Music Duration Time
    This parameter defines the doorbell music duration time when the siren receives a notification report. The doorbell music will be played always if it is set to ‘255’. The doorbell music will not be played if it is set to ‘0’. Other values are the doorbell music playing duration time. Parameter Number| Size| Available settings| Default
    ---|---|---|---
    3| 1| 0 ~ 255| 1

  2. Configure Door Bell Music Volume
    This parameter defines the output volume when the siren is playing doorbell music. The volume is divided into 3 steps, low (set to ‘1’), middle (set to ‘2’), and high (set to ‘3’). The default value is ‘1’. Parameter Number| Size| Available settings| Default
    ---|---|---|---
    4| 1| 0 ~ 10| 10

  3. Configure Alarm Music
    This parameter defines the alarm music for the siren to play if an alarm occurs. There are 10 different tunes the user can select. Parameter Number| Size| Available settings| Default
    ---|---|---|---
    5| 1| 0 ~ 10| 10

  4. Configure Door Bell Music
    This parameter defines the doorbell music for the siren to play if an alarm occurs. There are 10 different tunes the user can select. Parameter Number| Size| Available settings| Default
    ---|---|---|---
    6| 1| 0 ~ 10| 9

  5. Configure Default Siren On Mode
    This parameter defines the default music, volume, and duration time for the siren. ALARM MUSIC and DOORBELL MUSIC can be selected.
    The ALARM MUSIC MODE is defined by parameters #1, #2, and #5, and the DOORBELL MUSIC MODEis defined by parameters #3, #4, and #6.
    If set to ‘1’, the siren will select the  ALARM MUSIC MODE, if set to  ‘2’, the siren will select the DOORBELL  MUSIC MODE. Parameter Number| Size| Available settings| Default
    ---|---|---|---
    7| 1| 1 ~ 2| 1

  6. Configure Alarm LED Enable
    This parameter defines the default LED enable status when the siren is in the ALARM MUSIC MODE. If set to ‘0’, the LED is disabled, if set to ‘1’, the LED is enabled and when the siren is on the LED will blink.

Parameter Number Size Available settings Default
8 1 0, 1 1
  1. Configure Door Bell LED Enable
    This parameter defines the default LED enable status when the siren is in the DOORBELL MUSIC MODE. If set to ‘0’, the LED is disabled, if set to ‘1’, the LED is enabled and when the siren is on the LED will blink.
Parameter Number Size Available settings Default
9 1 0, 1 0

Command Class Interact
Binary Switch Command Class
The siren alarm can be turned on and off by the COMMANDCLASS SWITCH_BINARY. Which music is played by the siren is decided with the advanced configuration parameter #5. When the siren stops playing the alarm music, it will send a SWITCH_BINARY_REPORT = 0x00 to the controller.

Siren Alarm On:
Command Class: COMMAND_CLASS_SWITCH_BINARY
Command: SWITCH_BINARY_SEND
Value: 0xFF

Siren Alarm Off:
Command Class: COMMAND_CLASS_SWITCH_BINARY
Command: SWITCH_BINARY_SEND
Value: 0x00

Basic Command Class
The functions of BASIC_SET = 0x00 and BASIC_SET = 0xFF are same to Binary Switch Command Class.
Indicator Command Class
The INDICATOR_SET value indicates which music will be played. For example: With INDICATOR_SET = 0x01, the siren will play the first music.

See the table below:

Command Music Parameter volume / music
INDICATOR_SET = 0x01 1 Defined by  #1, #4, #5, #6
INDICATOR_SET = 0x02 2 Defined by  #1, #4, #5, #6
INDICATOR_SET = 0x03 3 Defined by  #1, #4, #5, #6
INDICATOR_SET = 0x04 4 Defined by  #1, #4, #5, #6
INDICATOR_SET = 0x05 5 Defined by  #1, #4, #5, #6
INDICATOR_SET = 0x06 6 Defined by  #1, #4, #5, #6
INDICATOR_SET = 0x07 7 Defined by  #1, #4, #5, #6
INDICATOR_SET = 0x08 8 Defined by  #1, #4, #5, #6
INDICATOR_SET = 0x09 9 Defined by  #1, #4, #5, #6
INDICATOR_SET = 0x0A 10 Defined by  #1, #4, #5, #6

Other INDICATOR_SET values are invalid for this siren.

Notification Command Class
If the siren receives a command from associated devices or the controller to play any music, the siren will send an active notification to the controller.
If the siren stops playing the music,  it will send a no-active notification to the controller.

Notification Report Command:
Siren Active:
Command Class: COMMAND_CLASS_NOTIFICATION
Command: NOTIFICATION_REPORT
Notification Type: NOTIFICATION_TYPE_SIREN
Event: NOTIFICATION_EVENT_SIREN_ACTIVE

Siren No Active:
Command Class: COMMAND_CLASS_NOTIFICATION
Command: NOTIFICATION_REPORT
Notification Type: NOTIFICATION_TYPE_SIREN
Event: NOTIFICATION_EVENT_SIREN_NO_EVENT

Battery Check Command
Users can enquire about the battery status of the siren alarm by sending the BATTERY_GET command. Once the siren alarm receives the command, it will return the BATTERY_REPORT command.
The siren alarm will send BATTERY_LEVEL = 0xFF command to the Z-Wave controller to inform that the siren alarm needs new batteries; otherwise, the BATTERY_LEVEL value range is 0% to 100%.

Command Classes
The siren alarm supports the Command Classes as below:

  • COMMAND_CLASS_ZWAVEPLUS_INFO (V2)
  • COMMAND_CLASS_VERSION (V2)
  • COMMAND_CLASS_MANUFACTURER_SPECIFIC (V2)
  • COMMAND_CLASS_DEVICE_RESET_LOCALLY (V1)
  • COMMAND_CLASS_POWERLEVEL (V1)
  • COMMAND_CLASS_BATTERY (V1)
  • COMMAND_CLASS_ASSOCIATION (V2)
  • COMMAND_CLASS_ASSOCIATION_GRP_INFO (V1)
  • COMMAND_CLASS_WAKE_UP (V2)
  • COMMAND_CLASS_SWITCH_BINARY (V1)
  • COMMAND_CLASS_NOTIFICATION (V6)
  • COMMAND_CLASS_CONFIGURATION (V1)
  • COMMAND_CLASS_INDICATOR (V1)

Guarantee

  1. The Guarantee is provided by our company (hereinafter “Manufacturer”)

  2. The Manufacturer is responsible for equipment malfunction resulting from physical defects (manufacturing or material) for 12 months from the date of its purchase.

  3. During the Guarantee period, the manufacturer shall repair or replace any defects, free of charge.

  4. In special cases, when the device cannot be replaced with a device of the same type (e.g. the device is no longer available in the commercial offer), the Manufacturer may replace it with a different device that has similar technical parameters as the faulty one.
    Such activity shall be considered as fulfilling the obligations of the Manufacturer. The Manufacturer shall not refund the money paid for the device.

  5. The guarantee shall not cover:
    • mechanical damages (cracks, fractures, cuts, abrasions, physical deformations caused by impact, falling, or dropping the device or other objects, improper use or not observing the operating manual)
    • damages resulting from external causes such as e.g. flood, storm, fire, lightning, natural disasters, earthquakes, war, civil disturbance, force majeure, unforeseen accidents, theft, water damage, liquid leakage, battery spill, weather conditions, sunlight, sand, moisture, high or low temperature, air pollution
    • damages caused by malfunctioning software, attack of a computer virus, or failure to update the software as recommended by the Manufacturer.

Disposing and recycling your product
When the device reaches its end of life, dispose of it according to your local environmental laws, guidelines, and regulations.
The WEEE symbol on the product or the packaging means that according to local laws and regulations it needs to be disposed of separately from household waste.
Once this product has reached the end of its life, please take it to a collection point (recycle facility) designated by your local authorities. By recycling the product and its packaging you help to conserve the environment and protect human health.

Manufacturer

Shenzhen Neo Electronics Co., LTD
Address: 6 th
Floor, Building No.2, Laobing Industrial Park, Tiezhai Road Xixiang, BaoAn District, Shenzhen, China
Web: https://www.szneo.com
Tel: +86-4007-888-929
Fax: +86-755-29667746
E-mail: support@szneo.com

All above is for references only, please see the subject on products.
Version: 51 / 2020

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)