Marathon Lighting ML-HB-4-T8 Lamp Ready Wrap Fixture Instruction Manual

June 6, 2024
Marathon Lighting

Marathon Lighting ML-HB-4-T8 Lamp Ready Wrap Fixture

Product Information

  • Specifications:
    • Model: ML-HB-4-T8, ML-HB-6-T8
    • Color: Black and White
    • Power: LED
    • Installation: Ceiling mount

Product Usage Instructions

  • Installation:
    • Remove the blue tape from the reflector.
    • Securely affix two chains of equal length to the ceiling.
    • Hang the chains onto the V hooks found on the back of the luminaire.
    • Connect the power cable to the junction box wires: ground wire to manufacturer’s ground wire, LIVE wire to manufacturer’s power wire, and neutral wire to manufacturer’s neutral wire.
    • Install the lamp or lamps in the luminaire.
    • Install the wire guard if needed.
    • Turn on the luminaire.
  • Wire Guard Installation:
    • Install the wire guard using 3 retaining brackets and 3 screws on each side of the housing.
  • Lamps Installation:
    • Check that the lamp’s maximum wattage and type agree with the luminaire’s nameplate ratings. Insert the lamps into the sockets and turn 90 degrees for proper contact.

FAQs

  • Q: How do I know if the lamp wattage is compatible with the luminaire?
    • A: Check the luminaire’s nameplate ratings and ensure that the lamp’s maximum wattage matches.
  • Q: What should I do if the luminaire does not turn on after installation?
    • A: Double-check the wiring connections to ensure they are correctly matched (ground to ground, live to power, neutral to neutral). If issues persist, contact customer support for assistance.

SAFETY PRECAUTIONS

  • WARNING: RISK OF FIRE OR ELECTRIC SHOCK. THE INSTALLATION SHOULD BE PERFORMED ONLY BY A QUALIFIED ELECTRICIAN BY THE NATIONAL ELECTRICAL CODE AND RELEVANT LOCAL CODES. THIS PRODUCT MUST BE INSTALLED IN FULL ACCORDANCE WITH APPLICABLE.
  • TO PREVENT ELECTRICAL SHOCK, MAKE SURE TO TURN OFF THE POWER SWITCH BEFORE THE INSTALLATION.

WIRING DIAGRAMS

TYPE B(BYPASS) ML-HB-4-T8

Marathon-Lighting-ML-HB-4-T8-Lamp-Ready-Wrap-Fixture-FIG-1
\(1\)

TYPE B(BYPASS) ML-HB-6-T8

Marathon-Lighting-ML-HB-4-T8-Lamp-Ready-Wrap-Fixture-FIG-1
\(2\)

INSTALLATION

ALWAYS TURN OFF THE POWER SUPPLY FROM THE MAIN CIRCUIT BREAKER FIRST!

  1. Remove the blue tape from the reflector.
  2. Securely affix two chains of equal length of equal length to the ceiling.
    • Hang the chains onto the V hooks found on the back of the luminaire.
  3. Connect the power cable, installed on the access plate, to the junction box wires as follows: ground wire to manufacturer’s ground wire, LIVE wire to manufacturer’s power wire, and neutral wire to manufacturer’s neutral wire.
  4. Install the lamp or lamps in the luminaire.
  5. Install the wire guard (in option)
  6. Turn on the luminaire.Marathon-Lighting-ML-HB-4-T8-Lamp-Ready-Wrap-Fixture-FIG-1 \(3\)

LAMPS INSTALLATION

  • Check that the LAMP MAXIMUM WATTAGE and TYPE agree with the luminaire’s nameplate ratings. Insert the lamps into the sockets and turn 90 degrees for proper contact.