Marathon Lighting ML-GC-2347 LED Lighting Fixture Installation Guide

June 16, 2024
Marathon Lighting

Marathon Lighting Logo LED Lighting Fixture
Installation Guide

ML-GC-2347 LED Lighting Fixture

SAVE THESE INSTRUCTIONS
BEFORE YOU BEGIN
Read and follow all safety instructions

WARNING

RISK OF FIRE, EXPLOSION AND ELECTRIC SHOCK

  • This product should be installed, inspected, and maintained by a qualified electrician only , in accordance with the NEC (National Electric Code) and all local codes.
  • Turn off electrical power before inspection, installation or removal.
  • Use only UL (or other NTRL) approved wire for input/ou tput connections.
  • Minimum size 18 AWG or 14 AWG for continuous runs.
  • Make sure LEDs and drivers are cool to touch when performing maintenance.
  • Make sure the supply voltage is the same as the rated voltage of the luminaire.
  • Do not install in a hazardous atmosphere, except where the ambient temperature does not exceed the rated operating temperature of the fixture.
  • Keep tightly closed when in operation

Prepare Electrical Wiring

Electrical Requirements

  • The LED driver must be supplied with 120 to 277V, 50/60 Hz and connected to an individual, properly grounded branch circuit protected by a 20 Ampere circuit breaker. Use min. 75°C supply.

Grounding Instructions

  • The grounding and bonding of the overall system shall be done in accordance with NEC Article 600 and local codes

LED Canopy Light

Tools Required :
Philli ps Screw Drivers
Wire Strippers
Wire Cutters

  • Before start ing ensure that the power is disconnected.

  • Unpack fixture and ensure that there are no damaged part s.

  • If mounting on surface:

  • The included quick mount is used to be mounted onto a recessed junction box.

  • Install the quick mount plate t o the junction with 2 screw (Not Provided).

  • Hang the fixture to t he quick mount on the metal loop on the fixt ure.

  • Connect the power leads wit h the included wire nuts as seen below.
    Black to Black(Hot), Whit e to Whit e(Neutral), Green to Green(Ground).

  • Push the connection splices int o the junction box and secure the fixt ure onto t he quick mount bracket and secure wit h the set screw.

  • If mounting on pendant stem:

  • Remove wire plug from top of fixt ure to expose t he NPS thread.

  • Feed housing wires through pendant stem.

  • Make wiring connections as seem below to junction box Black to Black(Hot), Whit e to Whit e(Neutral), and Green to Green(Ground).

  • Thread pendant pipe to top of housing. Be sure to wrap Teflon tape or silicone gel to thread of pipe to prevent moisture from entering.

Standard Wiring Diagram

Marathon Lighting ML-GC-2347 LED Lighting Fixture - Standard Wiring
Diagram

Marathon Lighting Logo

Documents / Resources

| Marathon Lighting ML-GC-2347 LED Lighting Fixture [pdf] Installation Guide
ML-GC-2347 LED Lighting Fixture, ML-GC-2347, LED Lighting Fixture, Lighting Fixture, Fixture
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Marathon Lighting User Manuals

Related Manuals