traxon Media Tube HO Floor Lighting Installation Guide

June 5, 2024
traxon

traxon Media Tube HO Floor Lighting

traxon-Media-Tube-HO-Floor-Lighting-PRODUCT

INTRODUCTION

General

MEDIA TUBE® HO RGBW DIRECT VIEW

|

MEDIA TUBE® HO RGBW DIFFUSED

|

Length (mm)

|

Maximum number of pixels (PXL)

---|---|---|---
TU.CS.1112001| TU.DS.1112001| 296| 12
TU.CS.2124001| TU.DS.2124001| 596| 24
TU.CS.3136001| TU.DS.3136001| 896| 36
TU.CS.4148001| TU.DS.4148001| 1196| 48
TU.CS.5160001| TU.DS.5160001| 1496| 60

Media Tube® HO is an IP66-rated slim LED tube for any wall or façade media lighting. Available in 296mm, 596mm, 896mm, 1196mm and 1496mm lengths, the simple but robust construction, allows 18.3m of tubes to be daisy chained on a single power run. The Media Tube® HO is controllable by DMX512 / e:pix / DVI capable with auto-addressing to the next tube in the daisy chain. The Media Tube® HO is housed in aluminium extrusion with a clear PC cover for direct view or with a diffused PC cover for diffused view.

Features:

  • Available lengths: 296mm (12PXL), 596mm (24PXL), 896mm (36PXL), 1196mm (48PXL) and 1496mm (60PXL)
  • Direct View or Diffused View
  • Three color options: RGBW, RGB, White (*available upon request)
  • DMX512 / e:pix / DVI capable
  • Daisy Chain System
  • Auto-Addressing
  • SMART CHIP™ Technology
  • Outdoor Applications (IP66-rated)

Dimensions

Media Tube® HO Direct View

traxon-Media-Tube-HO-Floor-Lighting-1

Media Tube® HO Diffused View

traxon-Media-Tube-HO-Floor-Lighting-2

Packing Contents

traxon-Media-Tube-HO-Floor-Lighting-3

INSTALLATION

Points To Consider
Plan your installation before mounting the Media Tubes® HO. The following should be considered for a successful installation.

  • Weather conditions and ambient temperature of installation site.
  • Appropriate cable lengths (cable gauges described in below diagram). Please consult your local Traxon office or authorized agent for necessary aid.
  • The number of Media Tubes® HO and appropriate LED Engines.
  • DMX512/e:pix controller to be used to control the Media Tubes® HO.
  • Distance between each Tube for thermal expansion and maintaining pixel pitch.
  • There are two mounting methods to consider, plan mounting distances accordingly for whichever method is required.
  • Proper surge protection.
  • Number of standard LED Engines to be used.

Media Tube® HO Cable System

traxon-Media-Tube-HO-Floor-Lighting-4

Pre-Installation Checks

Installation Checklist

  1. Prepare cables and all necessary accessories (Mounting Brackets, Waterproof Quick Lock End Caps etc).
  2. Perform functional check of Media Tubes® HO. Take care not to damage cables/connectors during pre-installation checks.
  3. Ensure all pre-installation checks laid out below have been followed.
  4. Mount the Media Tubes® HO on-site. If the installation is to be left uncompleted overnight, place all non-connected LED Engines and Media Tubes® HO in an indoor environment.

Ensure all the Interconnection Cables, Media Tubes® HO and LED Engines are initially stored in a dry area to guarantee the complete sealing of the system from water before installation.

Cable Bending
To reduce stress induced on Media Tube® HO lead cables, please adhere to the Minimum Bending Radius of 10mm (0.4”) and the Non-Bendable Length of 20mm near the connector. It is recommended to install lead cables through conduits/trunking.

Minimum Cable Bending and Non-Bendable Length requirement

NOTE : Water ingress incurred due to cable twisting or excess cable bending will not be under warranty by Traxon Technologies.

Mounting Bracket
If the Mounting Bracket method of installation is used, it is recommended to fix it to the installation surface before the Media Tube® HO is secured to the bracket

Media Tube® HO Mounting Bracket

Installation Sequence

  1. Plan for any possible bending of cables (see Section 2.2.2).
  2. Measure the correct distances for Mounting Brackets.
  3. Connect Media Tubes® HO with LED Engines in the daisy-chain manner outlined in the System Diagram to form large installations.
  4. Perform functional check on all Media Tubes® HO and inspect cables and Mounting Bracket for any damage. Check for any abnormalities with the control signal.
  5. Report any functional defect found to your nearest Traxon Technologies office. DO NOT attempt to install Media Tubes® HO with functional defects on-site.

On-Site Installation

  • DO NOT attempt installation in wet or severe weather conditions.
  • DO NOT leave and expose any Media Tubes® HO or LED Engines unconnected under wet/raining or snowing environment.
  • IP failure induced by stressed/damaged cables during or after installation will not be under warranty by Traxon Technologies.
  • ALWAYS keep the cables protected from sharp objects and ensure no damage is generated on the cable.

Failure to keep Media Tube® HO within the operating temperature range of –30°C to +55°C / –22°F to +131°F and storage temperature range of –40°C to +70°C / –40°F to +158°F will void the product’s warranty.

On-Site Installation

  1. Fix Mounting Bracket to installation surface with anchor bolts, if Mounting Bracket method is being used.
  2. Attach Media Tube® HO to Mounting Bracket and affix Mounting Plate (see below diagram). If using the Mounting Studs option, simply secure using anchor bolts (see Mounting options for the Tube

Fixing the Mounting Bracket to Installation Surface

traxon-Media-Tube-HO-Floor-Lighting-7

The Media Tubes® HO are interconnected using the IN and OUT cables on each end of the tube. Screw the connectors tightly for a water-tight seal. Below diagram shows the Tube connections. Always remember to affix an Quick Lock Waterproof End Cap (sold separately) for the OUT connector of the final Tube in each daisy chain. See System Diagram for details.

traxon-Media-Tube-HO-Floor-Lighting-8

Be sure not to compress the IN/OUT cables (see Requirements Of Cable Bending).

NOTE: To keep LED pitch consistent and allow for thermal expansion, be sure to keep a minimum distance of 4mm (0.16”) between consecutive Media Tubes® HO (see below diagram).

traxon-Media-Tube-HO-Floor-Lighting-9

Connect Media Tubes® HO in the daisy-chained manner as detailed in the System Diagram. There are two mounting options.

traxon-Media-Tube-HO-Floor-Lighting-10

The first tube of the daisy-chain group has to be connected to the control system via the Quick Lock Starter Cable or the RJ45 / Power Data to Quick Lock Injector Cable Kit (TU.AC.0600400). Starter cables, Data and Power cables, and video fiber optic cables have to be installed through conduits/trunking.

traxon-Media-Tube-HO-Floor-Lighting-11

Set up the control system indoors as detailed in the System Diagram and connect to the Media Tubes® HO outside. Start up each unit and verify correct function.

SAFETY AND OPERATION

  • CAUTION – Unplug the power supply from the mains power before connecting any cables as this can damage the products.
  • CAUTION – Avoid looking directly into the LED light source at close range for your own safety.
  • Persons installing this product should make sure:
    • The installation complies with all applicable codes, state and local laws, ordinances, standards and safety regulations.
    • The installation environment is carefully studied and suitable surge protection measure(s) is taken.
    • He or she is qualified for the handling of electrical equipment.
  • Do not attempt to install or use the product until installation instructions and safety labels are fully understood. This product is designed for indoor and outdoor use.
  • Ensure product operates within the specified temperature range. (Refer to 7. TECHNICAL SPECIFICATION for more details.)
  • Do not attempt to open the product. Not user serviceable.
  • Do not use the product if any part of it, or the power cables are damaged.
  • Only use product for specified voltage, do not exceed. (Refer to 7. TECHNICAL SPECIFICATION for more details.)
  • Always maintain connection to ensure waterproofing.
  • If the product has been subjected to drastic temperature variances, for example, following transportation, do not connect the fixture until it has reached room temperature, as moisture condensation may cause electric shock and product damages.
  • When installing the products and system power supplies, please ensure they will not be exposed to moisture and extreme heat (and direct sunlight for outdoor products). Besides, keep a clean operating environment for the fixtures and system power supplies.
  • Please study this Installation Guide thoroughly and check the latest Technical Specification Sheets available from the Traxon website www.traxontechnologies.com before setup.
  • Any non-compliance of the Installation Guide will void the Traxon warranty.

SYSTEM CONFIGURATION

MEDIA TUBE® HO CONNECTION COMPONENTS
The Media Tube® HO is connected using a daisy chain system with power and data on the same cable. Below diagram shows some typical components for Media Tube® HO system.

traxon-Media-Tube-HO-Floor-Lighting-12

LED CONTROL
The LEDs on the Media Tube® HO are controlled by DMX512/e:pix. Each pixel on the Tube uses four (4) channels, for R, G, B and W. Pixel number 1 begin on the IN connector side, and it uses the first four channels.

traxon-Media-Tube-HO-Floor-Lighting-13

Media Tube® HO RGBW 1000W 7A Fuse Per Daisy Chain System Connection Example

traxon-Media-Tube-HO-Floor-Lighting-14

Media Tube® HO RGBW 1000W 6A Fuse Per Daisy Chain System Connection Example

traxon-Media-Tube-HO-Floor-Lighting-15

Media Tube® HO RGBW System 240W Outdoor Connection Example

traxon-Media-Tube-HO-Floor-Lighting-16

Media Tube® HO RGBW System 100W Outdoor Connection Example

traxon-Media-Tube-HO-Floor-Lighting-17

CARE AND MAINTENANCE

Traxon™ products are of superior design and quality and should be treated with care. The recommendations below will help fulfill any warranty obligations and gain good use and longevity from the products.

  • Do not attempt or use the product(s) until you read and understand the installation instructions. Failure to adhere to these instructions could result in serious injury or property damage.
  • Do not use product(s) if cables are damaged.
  • Do not connect cables and connectors when wet or in wet area. Moisture on bare connectors can cause electric shock and damage to product(s).
  • Do not use product(s) in extreme heat environment. Ensure there is sufficient airflow and use cool air circulation if required.
  • Do not drop, knock, or shake product(s). Rough handling can damage the electronics and void the warranty.
  • Do not use harsh chemicals, cleaning solvents, or strong detergents to clean products. Wipe with a damp cloth on housings and a dry cloth on electronics to remove dirt or dust.
  • Do not attempt to service or repair the product(s) unless done by an authorized service personnel. Contact your local Traxon office or distributor for details.
  • If the product is not working as specified, please contact your nearest authorized service center or Traxon Technologies office for assistance.

TROUBLESHOOTING

traxon-Media-Tube-HO-Floor-Lighting-18

If problems persist or the product is not working as specified, please contact your nearest authorized service center or Traxon Technologies office for assistance.

TECHNICAL SPECIFICATION

Media Tube® HO RGBW|
---|---
Color Range:| 16.7 million additive RGB colors; White CCT 6500K
Light Source:| High intensity SMT RGB and White LEDs
Beam Angle:| 110° (direct view); 175°(diffused)
Power Input*:| 48V DC
Power Consumption (typ).:| 4.6W / 8.6W / 12.5W / 16.6W / 20.9W
Weight:| 0.36kg / 0.58kg / 0.8kg / 1.02kg / 1.24kg (direct view) 0.4kg / 0.52kg / 0.84kg / 1.06kg / 1.28kg (diffused)
Operating Temperature:| –30°C to +55°C / –22°F to +131°F
Storage Temperature:| –40°C to +70°C / –40°F to +158°F

For use with TRAXON LED Engine 1000W 48V Indoor (PS.IE.0011100), LED Engine 240W 48V Outdoor (PS.OB.0011002), LED Engine 100W 48V Outdoor (PS.CU.0000008) PSUs.
As with all electronic devices, LED output degrades over time – a term called lumen depreciation. This also explains why it is nearly impossible to expect photometric performances of two LED products with different service life spans to be the same. The rate of LED degradation is a complex function of many factors such as operating efficiency, duration of continuous operation, and operating conditions (e.g. ambient temperature).
Because LEDs are semiconductor devices, their performances are subject to inherent variability commonly found in semiconductor industry. To improve consistency in performance across the same product, LED manufacturers “sort” LEDs into bins according to different preset parameters, such as forward driving voltage, illumination, etc. Whereas binning is a sorting function, it is not a correction process. Inherent variability in the manufacturing process always results in different binning distributions according to different production lots. Traxon uses automatically binned LEDs on its products, thereby minimizing output variations within the model range.

WARRANTY STATEMENT

Traxon Technologies warrants its Products against material or workmanship defects for a period of five (5) years from date of purchase, provided that the purchased items are used under the conditions stated in this user manual. Please refer www.traxontechnologies.com for all warranty terms and conditions.

Please check for the latest updates and changes on the Traxon website.
© 2022 TRAXON TECHNOLOGIES ALL RIGHT RESERVED. Information is subject to change without prior notice. www.traxontechnologies.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

traxon User Manuals

Related Manuals