TRAXON AM461810055 Allegro Dot XS PXL Distributor Installation Guide

June 17, 2024
traxon

TRAXON-logo

TRAXON AM461810055 Allegro Dot XS PXL Distributor

TRAXON-AM461810055-Allegro-Dot-XS-PXL-Distributor-
product

Product Information

Specifications:

  • Model: PXL Distributor Pro 8 (AM461810055)
  • Dimensions:
    • Width: 96.00mm (3.78 inches)
    • Height: 108.00mm (4.25 inches)
    • Depth: 235.00mm (9.25 inches)

FAQ

  • Q: Can the product be submerged in water?
    • A: No, the product should not be submerged. It should be mounted on a smooth and rigid surface.
  • Q: What outdoor power cable options can be used with the product?
    • A: Suitable outdoor power cable options include SJTW 16AWG x 3C, SJOW 16AWG x 3C, and H05RN-F 3 x 1.0mm2.

Product Usage Instructions

Mounting:

  • Mount the product on a smooth and rigid surface. Make sure it is not submerged in water.

Installation:

  • Follow the mounting guide provided in the manual.
  • Use appropriate outdoor power cable options like SJTW 16AWG x 3C, SJOW 16AWG x 3C, or H05RN-F 3 x 1.0mm2.

Connection:

  • Connect the product using the 3-pin field-installable connector PD8 IP67 (AM461770055).
  • Refer to the wire descriptions for proper connection: Live (1), Neutral (2), Earth (3).

End Cap:

  • For the last data injector in a chain, use an end cap to seal the DATA OUT connector with a tightening torque of 0.9Nm.

Dimension

PXL Distributor Pro 8 (AM461810055)

TRAXON-AM461810055-Allegro-Dot-XS-PXL-Distributor-
fig-1

3PIN FIELD INSTALLABLE CONNECTOR PD8 IP67 (AM461770055)

TRAXON-AM461810055-Allegro-Dot-XS-PXL-Distributor-
fig-3

  • Solder type field-installable connector

Outdoor power cable options (provided by others):

  • SJTW 16AWG x 3C
  • SJOW 16AWG x 3C
  • H05RN-F 3 x 1.0mm2
  • Cable OD ɸ6.5 – 9.5mm

Wire# / Description

  • 1 / Live
  • 2 / Neutral
  • 3 / Earth

Mounting

TRAXON-AM461810055-Allegro-Dot-XS-PXL-Distributor-
fig-4

IMPORTANT:

  • For the last data injector in a chain, use end cap to seal the D ATA OUT connector.
  • Tightening torque: 0.9Nm

PRECAUTIONS

WARNING

  • CONNECT TO THE POWER SUPPLY IN ACCORDANCE WITH NATIONAL REGULATIONS.
  • IF THE EXTERNAL FLEXIBLE CABLE OF THIS LUMINAIRE IS DAMAGED, IT SHALL BE EXCLUSIVELY REPLACED BY THE MANUFACTURER OR A SIMILAR QUALIFIED PERSON IN ORDER TO AVOID ANY HAZARD.
  • INSTALLATION/MAINTENANCE ONLY BY SKILLED PERSONNEL.
  • DURING OVERHAUL/MAINTENANCE ONLY USE ORIGINAL PARTS.
  • IF ANY LUMINAIRE IS SUBSEQUENTLY MODIFIED, THE PERSON RESPONSIBLE FOR THE MODIFICATION SHALL BE CONSIDERED THE MANUFACTURER.
  • THE MANUFACTURER BEARS NO LIABILITY FOR DAMAGE CAUSED BY INAPPROPRIATE USE OR APPLICATION.

www.traxon-ecue.com

©2023 TRAXON TECHNOLOGIES. ALL RIGHTS RESERVED.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals