TRAXON XB.W7.8310110 150W Allegro Washer AC Installation Guide
- June 1, 2024
- traxon
Table of Contents
TRAXON XB.W7.8310110 150W Allegro Washer AC
Product Information
Specifications
- Power: AC 150W/200W
- Dimensions: 170mm x 320mm x 420mm
- Weight: 392mm
- Optional Safety Cable: 1.5 – 2.3mm
- Cable Connectors: XB.AC.3106000 (for cable OD 6-10mm), XB.AC.4006000 (for cable OD 10-14mm) , pin)
- Tightening Torque: 3.5Nm, 0.8 – 1.0 Nm
- Bending Radius: 4D
- IP Rating: IP66
Product Usage Instructions
Mounting the Bracket
- Tilt the head slightly to mount the bracket.
- Turn enough to unlock but do not unscrew the hex screw from the fixture.
Adjustment and Locking
- Adjust the position as needed and ensure to lock it securely in place.
Optional Safety Cable Installation
- If using the optional stainless steel safety cable, follow the manufacturer’s instructions for installation.
Cable Connector Installation
- Follow the provided guidelines for installing the field-installable connectors. Avoid vertical placement if possible.
Ventilation
- Do not obstruct the vent hole for proper ventilation of the unit.
FAQ
- Q: What is the recommended tightening torque for the screws?
- A: The recommended tightening torque is 3.5 Nm for the main screws and 0.8 – 1.0 Nm for cable connectors.
- Q: Can I install the connectors in a vibrating environment?
- A: It is advised not to put excessive force or install connectors in a vibrating environment to ensure proper functionality.
Dimension
Installation Instructions
Allegro Washer AC 150W/200W Mounting Guide
Applicable to Field Installable Connectors
To properly bend the cable
- Cable must NOT bent below the Minimum Bending Radius (4 x Cable Diameter) as specified by the cable manufacturer and the nonbendable length of 5cm near the connector end MUST be adhered to.
- Note the minimum bending radius for conductors > 1.5mm?.
- Pull forces on the contact points can be avoided by bending the wire de ramitirani
Avoid vertical placement of the connectors
If vertical installation is unavoidable:
- Add silicone glue on the surface of cable gland.
- Layout the cable to have a drip loop to allow water to run off the wire.
- XB.AC.3106000 (for cable OD 6-10mm)
- XB.AC.4006000 (for cable OD 10-14mm)
- 3-pin Field Installable AC Female Connector IP66
- XB.AC.2302000
- 5-pin Field Installable AC Male Connector IP66 (for cable OD 10-14mm)
- XB.AC.2303000
- 5-pin Field Installable AC Female Connector IP66 (for cable OD 10-14mm)
- Remember to tighten the cable gland after installation.
- Make sure the cable gland also tightens the cable sheath.
CONNECT TO THE POWER SUPPLY IN ACCORDANCE WITH NATIONAL REGULATIONS
- IF THE EXTERNAL FLEXIBLE CABLE OF THIS LUMINAIRE IS DAMAGED, IT SHALL BE EXCLUSIVELY REPLACED BY THE MANUFACTURER OR A SIMILAR QUALIFIED PERSON IN ORDER TO AVOID ANY HAZARD.
- INSTALLATION/MAINTENANCE ONLY BY SKILLED PERSONNEL.
- DURING OVERHAUL/MAINTENANCE ONLY USE ORIGINAL PARTS.
- IF ANY LUMINAIRE IS SUBSEQUENTLY MODIFIED, THE PERSON RESPONSIBLE FOR THE MODIFICATION SHALL BE CONSIDERED THE MANUFACTURER.
- THE MANUFACTURER BEARS NO LIABILITY FOR DAMAGE CAUSED BY INAPPROPRIATE USE OR APPLICATION.
- THE LIGHT SOURCE OF THIS LUMINAIRE IS NOT REPLACEABLE; WHEN THE LIGHT SOURCE REACHES ITS END OF LIFE THE WHOLE LUMINAIRE SHALL BE REPLACED.
- THE LUMINAIRE SHOULD BE POSITIONED SO THAT PROLONGED STARING INTO THE LUMINAIRE AT A DISTANCE CLOSER THAN 7M IS NOT EXPECTED.
CONTACT
©2023 TRAXON TECHNOLOGIES. ALL RIGHTS RESERVED. TRAXONT™, TX CONNECT ®, ARE
TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS,
OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
www.traxon-ecue.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>