Saankhya Labs KAILASH5W00 BRH Kailash Unit Installation Guide

June 5, 2024
Saankhya Labs

Saankhya Labs - logo

BROADCAST RADIO HEAD

Saankhya Labs KAILASH5W00 BRH Kailash Unit

User Manual & Installation Guide

FCC Regulatory Information

FCC ID : 2AUUC-KAILASH5W00
§15.19

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:

(1) This device may not cause harmful interference (2) this device must accept any interference received, including interference that may cause undesired operation.
This device complies with Part 27 of FCC Rules. This provides reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

§15.21 Information to user
The users’ manual or instruction manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. In cases where the manual is provided only in a form other than paper, such as on a computer disk or over the Internet, the information required by this section may be included in the manual in that alternative form, provided the user can reasonably be expected to have the capability to access information in that form.

§15.105 Information to the user
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

FCC Caution!!!
Exposure to Radio Frequency Radiation

  • Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
  • This equipment should be installed and operated with a minimum distance of 150 cm between the antenna of this device and all persons.

Supplier’s Declaration of Conformity 47 CFR $ 2.1077 Compliance Information

Unique Identifier: Broadcast Radio Head
(FCC ID — 2AUUC-KAILASH5W00) Responsible Party
— U.S. Contact Information Saankhya Labs Inc No. 501, Seaport Court Suite 103A, Redwood City, CA 94063 Phone
— +1-(408)-464-8601 Email — Arvind@saankhyalabs.com

FCC Compliance Statement
This device complies with Part 15 of FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

The broadcast Radio Head (BRH) solution is a new paradigm for the Next-Gen Digital Terrestrial Transmission (DTT). Deployed in a Low-Power Low Tower (LPLT) topology, it can create uniformly high signal strength to support Direct to Mobile (DTM) indoor reception.
LPLT enables efficient spectrum reuse and can also supplement conventional High-Power High Tower (HPHT) deployments.
The Low-Power Low Tower (LPLT) networks for which this BRH Sub-system has been developed and expected to operate to provide Broadcast services in High Population Density/Low Population Density Areas.
The BRH Sub-systems operate in a 722 – 728MHz (Channel 56) band while avoiding interference to the other licensed operations.

Saankhya Labs KAILASH5W00 BRH Kailash Unit - dtm

BRH Deployment Diagram

In The Box

Equipment

|

Quantity

---|---
BRH Unit| 1 Nos
User Manual & Installation Guide| 1 Nos
M4 Screws (already mounted on the enclosure)| 1 Nos
Parameter|

Specification

---|---
Operating Frequency Band (MHz)| 722-728 MHz (Channel 56)
Channel Spacing (MHz)| 6 MHz
Transmitter Average Output| 5 W (37 dBm with tolerance –±0.5 dB)
Input Voltage| – 48 V
Maximum Power Consumption| 150 W
Enclosure Grade| IP65 Certified
Size (L.W.D)| 622 .172.2 .137 mm
Weight (kg)| 8 kg
FCC Compliance| FCC part 27 rules for operation in 700 MHz spectrum
Operating Temp Range| -40°C to +50°C
Supported Output Modulation| ATSC 3.0
Input Signal Type| DVB-S and DVB-S2 band frequency, 950-2150 MHz)

IEC-61000-4-5
Qualifies Level – 2 (1 VK)
For more than 1 KV surge protection, it is recommended to use additional external protection on the power line.

Pole mounting provision

  1. The connector side of the BRH Unit must be facing down
  2. All below connectors should be plugged in first a. GPS Plug b. Satellite Input c. ATSC 3.0 Output d. Ethernet plug e. Lightning Earthing
  3. An active Power plug with – 48V input voltage should be connected to the BRH Unit
  4. Securely fasten all screws on the Mounting brackets of the BRH Unit and the pole

EMS Providing

  1. Please refer to the ‘BRH EMS User Manual’ available after EMS login for users with Operators and Admin privileges
  2. Refer to the section, ‘EMS Workflows’—►provisioning—►`Provision a Device’
  3. The MAC Address of the Unit will be displayed on the unit for your reference
  4. Once the Device is provisioned and shows up in the BRH DEVICES list EMS provisioning procedure is completed

Power Up Procedure

  1. Once the Unit is installed and provisioned in EMS, follow steps (2-9) to power ON the Unit
  2. Check if the Ethernet plug being connected to the Unit has Internet access. Once done, connect the Ethernet plug
  3. Check if the F-type DVB-S2 plug is receiving a signal on EMS configured backhaul frequency. Once done, connect the F-type connector as DVB-S2 input
  4. Connect the N-type plug to GPS Receiver Antenna
  5. Connect the Output N-type plug to Transmission Antenna
  6. Verify that the Power Connector output gives – 48V
  7. Once below four plugs are plugged into the Unit securely, connect the power plug to the Unit at the very end, a.) RJ-45, Internet Connectivity b.) F-type, DVB-S2 Input c.) N-type, GPS Receiver d,) N-type, ATSC 3.0 output
  8. Unit boots up in —5mins after which the Unit should show up as active on the EMS login for the assigned Operator and statistics sent by the Unit should be visible on the EMS
  9. An active unit would start transmitting once GPS lock is achieved and according to configured settings on the EMS

S.No.

| Connector Name| Label on Box|

Connector Type

---|---|---|---
1| DVB-S2 L-Band Input| DVB-S2 Rx| F-Type Female
2| Ethernet Plug| RJ-45| RJ-45
3| 4 Pin Mini-Con-X – 48V Power Supply Connector| 4 Pin Power| Mini Con-X Female
4| GPS Input| GPS| N-Type Female
5| Antenna Output| ATSC-Tx| N-Type Female
6| Lightning Ground| Ground Symbol| Hole for M4 Screws

Saankhya Labs KAILASH5W00 BRH Kailash Unit - connector

The below diagram describes the pin configuration for the input power supply of +48V towards the Enclosure side.

Note: Above configuration has been provided for the connector on the Enclosure side and not on the input plug
Caution: Please verify the voltage supply on the input connector plug to match the above configuration before connecting to the BRH Unit

Do’s

  1. All connectors should be plugged in only after the BRH Unit is securely mounted on the pole
  2. After complete installation of all components, LNB Antenna, BRH Unit, etc, all should have a common ground
  3. Make sure – 48V is provided to the Mini-Con-X power supply connector according to provided pin diagram
  4. Make sure the transmitter antenna is properly connected to the BRH Unit before connecting the power supply
  5. Power ON the BRH Unit only after checking the common ground of the complete BRH System
  6. Please use a low-loss/high-power handling cable with a minimal length between the BRH Unit and Antenna systems
  7. The power plug should be connected at the very last
  8. BRH Unit should have access to EMS over connected Ethernet
  9. MAC ID of the BRH Unit should be registered on the Network and IP address should be assigned using an active DNS server
  10. On an active running BRH Unit, if the power plug is removed, a wait time of 4 minutes is expected before connecting back the power plug
  11. For any maintenance of the BRH Unit, EMS ‘Shutdown’ command should be used, and a wait time of 1 min is needed before removing the power plug
  12. BRH Unit should be added and defined on EMS before getting powered on. Please refer to the User Guide available at https://brh.saankhyalabs.com for instructions to define the current BRH Unit on EMS

Don’ts

  1. Removing the power plug and connecting it back immediately will not power up the unit properly
  2. During active operation of the BRH Unit, the transmitter antenna radiates RF energy. Do not stand in front or touch the antenna during active operation
  3. Under lab conditions, do not power ON the BRH Unit without connecting high power attenuators & antenna on the transmission port. Electronics on the BRH Unit will be damaged if an active transmission is done without connecting the proper attenuator and antenna
  4. BRH Unit should not be opened. Warranty will be void if done so

The device is unreachable on the network

Possible Cause

| Steps to Veri|

Steps to Resolve

---|---|---
Equipment is Powered Off| Verify if BRH Unit is drawing at least 300mA or more| 1.        Remove the power plug from the BRH Unit
2.        Wait for 4 minutes
3.        Connect the power plug to BRH Unit again
4.        Unit takes around 4 minutes to boot up completely and connect to EMS
DHCP Server failed to assign an IP address| Verify if the MAC ID of the BRH Unit is recognized by the DHCP server| 1.        IT team should add the MAC ID of the BRH Unit to their list of recognized devices
2.        [Good to have] DHCP Server should have MAC ID to IP binding
3.        Once done, remove the Ethernet plug and connect it back to BRH Unit
4.        Ping the IP address of the BRH Unit after a couple of minutes
The power plug on BRH Unit was removed and connected back immediately| | 1.        Remove the power plug from the BRH Unit
2.        Wait for 4 minutes
3.        Connect the power plug to BRH Unit again
4.        Unit takes around 4 minutes to boot up completely and connect to EMS

BRH Unit is not transmitting after “Power On”

Possible Cause| Ste s to Verify| Ste s to Resolve
---|---|---
BRH Unit is not provisioned on EMS| Check if the Device is provisioned on EMS with MAC ID| 1. Follow EMS Guide and provision the device with the MAC ID of the Device
2. Select proper configuration during provisioning of the device
BRH Unit is provisioned but EMS is still showing the unit is down| Check if the Unit,
1. Is powered ON
2. Is connected to EMS on the network| Refer to troubleshooting on ‘Device is Unreachable on Network’

If you need any assistance regarding the deployment or troubleshooting of the BRH Unit, please write to us at support-brh@saankhyalabs.com