MEAN WELL LPS-50 50W Single Output Switching Power Supply Instruction Manual

June 5, 2024
MEAN WELL

MEAN WELL LPS-50 50W Single Output Switching Power Supply Instruction Manual
MEAN WELL LPS-50 50W Single Output Switching Power
Supply

Features :

  • Universal AC input / Full range
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • Small and compact size
  • Built-in remote ON-OFF control
  • LED indicator for power on
  • 100% full load burn-in test
  • Low profile:23mm thickness
  • 2 years warranty

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTlN.aspx

SPECIFICATION

MODEL| LPS-50-3.3| LPS-50-5| LPS-50-12| LPS-50-15| LPS-50-24| LPS-50-48
---|---|---|---|---|---|---
OUTPUT| DC VOLTAGE| 3.3V| 5V| 12V| 15V| 24V| 48V
RATED CURRENT| 10A| 10A| 4.2A| 3.4A| 2.1A| 1.1A
CURRENT RANGE| 0 ~ 12A| 0 ~ 12A| 0 ~ 5A| 0 ~ 4.1A| 0 ~ 2.5A| 0 ~ 1.3A
RATED POWER| 33W| 50W| 50.4W| 51W| 50.4W| 52.8W
PEAK LOAD(10sec.) Note.4| 39.6W| 60W| 60W| 61.5W| 60W| 62.4W
RIPPLE & NOISE (max.) Note.2| 50mVp-p| 50mVp-p| 80mVp-p| 80mVp-p| 80mVp-p| 100mVp-p
VOLTAGE ADJ. RANGE| 3 ~ 3.6V| 4.5 ~ 5.5V| 10.8 ~ 13.2V| 13.5 ~ 16.5V| 21.6 ~ 27.2V| 43.2 ~ 52.8V
VOLTAGE TOLERANCE Note.3| ±3.0%| ±3.0%| ±2.0%| ±2.0%| ±1.0%| ±1.0%
LINE REGULATION| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LOAD REGULATION| ±3.0%| ±3.0%| ±2.0%| ±2.0%| ±1.0%| ±1.0%
SETUP, RISE TIME| 100ms, 40ms/230VAC        100ms, 40ms/115VAC at full load
HOLD UP TIME (Typ.)| 70ms/230VAC       12ms/115VAC at full load
INPUT| VOLTAGE RANGE| 90 ~ 264VAC       127 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY(Typ.)| 75%| 81%| 82%| 84%| 85%| 86%
AC CURRENT (Typ.)| 115VAC| 0.9A| 1.2A
230VAC| 0.6A| 0.8A
INRUSH CURRENT (Typ.)| COLD START 18A/115VAC      35A/230VAC
LEAKAGE CURRENT| <1mA / 240VAC
PROTECTION| OVERLOAD| 122 ~ 160% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE| 3.8 ~ 4.45V| 5.75 ~ 6.75V| 13.8 ~ 16.2V| 17.25 ~ 20.25V| 27.6 ~ 32.4V| 57.6 ~ 67.2V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
FUNCTION| REMOTE ON/OFF| RC+/RC- : 0 ~ 0.8V power on ; 4 ~ 10V power off
ENVIRONMENT| WORKING TEMP.| -20 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -20 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.04%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & **EMC (Note 5)| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC  O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55024, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, criteria A, EAC TP TC 020
OTHERS| MTBF| 3138.2K hrs min.    Telcordia SR-332 (Bellcore) ; 491.4K hrs min.    MIL-HDBK-217F (25℃)
DIMENSION| 1955523mm (LWH)
PACKING| 0.24Kg; 48pcs/12.5Kg/0.87CUFT
NOTE**|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 33.3% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
  5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMl testing of component power supplies.(as available on http://www.meanwell.com)
  6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

※ Product Liability Disclaimer:For detailed information, please refer to https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx)

Mechanical Specification

Mechanical Specification Mechanical
Specification

AC Input Connector (CN1) : JST B5P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1 AC/L JST VHR or equivalent JST SVH-21T-P1.1 or equivalent
2,4 No Pin
3 AC/N
5 FG

DC Output Connector (CN2) : JST B4P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1,2 -V JST VHR or equivalent JST SVH-21T-P1.1 or equivalent
3,4 +V

Remote ON/OFF Connector(CN3):JST B2B-XH or equivalent

Pin No. Assignment Mating Housing Terminal
1 RC+ JST XHP or equivalent JST SXH-001T-P0.6 or equivalent
2 RC-

: Grounding Required
CN1:Pin 5 is safety ground

Block Diagram

Block Diagram

Derating Curve

AMBIENT TEMPERATURE (℃)
Derating Curve

Static Characteristics (15V)

INPUT VOLTAGE (V) 60Hz
Static Characteristics \(15V\)

Icons

Documents / Resources

| MEAN WELL LPS-50 50W Single Output Switching Power Supply [pdf] Instruction Manual
LPS-50, 50W Single Output Switching Power Supply, LPS-50 50W Single Output Switching Power Supply, Single Output Switching Power Supply, Output Switching Power Supply, Switching Power Supply, Power Supply, Supply
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals