Features
- Constant Voltage PWM style output with frequency 1 KHz
- PCB type design
- Built-in active PFC function
- No load power consumption<0.5W
- Function options: 2 in 1 dimming (dim-to-off); Auxiliary DC output
- 3 years warranty
Applications
- LED strip lighting
- Indoor LED lighting
- LED decorative lighting
- LED architecture lighting
GTIN CODE
MW Search. haps://www.meanwell.corniserviceGTIN.aspx
Description
IDPV-65 series is a 65W PCB type AC/DC LED driver featuring the constant voltage mode PWM style output design. IDPV-65 operates from 180-295VAC and offers models with different rated voltages ranging between 12V and 60V. Thanks to the high efficiency of up to 90%, with the fanless design, the entire series is able to operate for -20 C-+40 C ambient temperature under free air convection. IDPV-65 is equipped with various function options, such as dimming methodologies, so as to provide design flexibility for the LED lighting systems.
Model Encoding
Type | Function |
---|---|
Blank | 2 in 1 dimming (0-10VDC and 10V PWM) |
A | 2 in 1 dimming and Auxiliary DC output |
SPECIFICATION
MODEL | IDPV-650-12 | ippv.650-24 | DPV-6036 | IDPV-6C-48 | IDPV-61:1-60 |
---|---|---|---|---|---|
OUTPUT | DC VOLTAGE | 12V | 24V | 36V | 48V |
RATED CURRENT | 4.2A | 2.4A | 1.8A | 1.35A | 1.08A |
RATED POWER | 50.4W | 57.6W | 64.8W | 64.8W | 64.8W |
DIMMING RANGE | 0-100% | ||||
VOLTAGE TOLERANCE | ± 10% | ||||
PWM FREQUENCY (Typ.) | 1KFtz(± 20%) | ||||
SETUP TIME Note.3 | 500ms /230VAC | ||||
AUXILIARY DC OUTPUT Nob/ | Nominal 12V(deviation 11.4-12.6)@50mA forA-Type |
only
INPUT| VOLTAGE RANGE Note.2| 180 – 295VAC 254 – 417VDC
(Please refer to ‘STATIC CHARACTERISTIC’ section)
FREQUENCY RANGE| 47 – 63Hz
POWER FACTOR crypt.)| PF>0.95/230VAC, PF>0.9/277VAC@ifull load
(Please refer to the ‘POWER FACTOR (PF) CHARACTERISTIC’ section)
TOTAL HARMONIC DISTORTION| THD< 20%(@loadM0%/230VAC; @load.475%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION’ section)
EFFICIENCY (Typ.)| 85%| I87%| I 88%| I 89%| I90%
AC CURRENT (Typ.)| 0.4A/230VAC 0.3A/277VAC
INRUSH CURRENT(Typ.)| COLD START 30A(twidth=270ps measured at 50% (peak) at
230VAC: Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 32 units (circuit breaker of
type B)/ 32 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA/ 277VAC
NO LOAD POWER CONSUMPTION| <0.5W
PROTECTION| SHORT CIRCUIT| Shutdown 0/P voltage, re-power on to recovery
OVER CURRENT| 105 -115%
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
ENVIRONMENT| WORKING TEMP.| Ta=-20 – +40 C (Please refer to” OUTPUT LOAD
vs TEMPERATURE’ section)
WORKING HUMIDITY| 20 – 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 – +80°C, 10 – 95% RH
TEMP. COEFFICIENT| ±0.03%/C (0 – 40°C)
VIBRATION| 10 – 500Hz, 2G 10min./Tricycle, period for 60min . each along X. Y.
Z axes
SAFETY & EMC| SAFETY STANDARDS| UL8750.CSA C22.2 NO.250.13-12;ENEC EIS EN/
EN61347-1 & BS EN!EN61347-2-13 independent, BS EN!EN62384approved
WITHSTAND VOLTAGE| I/P-0/P:3.75KVAC
ISOLATION RESISTANCE| I/P-0/P:100M Ohms / 500VDC / 25°Ci 70% RH
EMC EMISSION| Compliance to BS E N/E N55015, BS E N/EN61000-3-2 Class C
(tRbad:=60%); BS EN/EN61000-3-3
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS
EN/EN61547.1ight industry level(surge immunity: Lthe-Line:1KV)
OTHERS| MTBF| 3720.1K hrs min. Telcordia SR-332 (Bellcore); 398.8K hrs
min. MIL-HDBK-217F (25°C)
DIMENSION| 130’67.5’22mm (L’IN*F1)
PACKING| 0.15Kg;81pcs/13Kg/ 1.46CUFT
NOTE| 1. All parameters NOT specially mentioned we measured at 230VAC input,
rated current, and 25’C of ambient temperature.
2. Deleting may be needed under low input voltages. Please refer to b ‘STATIC
CHARACTERISTIC’ sections tar details.
3. Length of setup time is measured at cold first start. Turning OWOFF the
driver may lead to an increase in the setup __ time.
4. Aux. 12V will be damaged with a short circuit It will not be available
with dimming off or output no load condition.
5. The (liver is considered a component that a be operated in combination
with final equipment Since EMC performance will be affected by the
complete installation. the final equipment manufacturers must requalify EMC
Directive on the complete installation again.
※ Product Liability Disclaimer: For detailed information, please refer to
https://www.meamwell.con/servicedisclaimer.aspx
DIMMING OPERATION
※ Dimming principle for PWM style output
- Dimming is achieved by varying the duty cycle of the output current.
※ 2 in 1 dimming function
◎ Applying additive 0 ~ 10VDC
◎ Applying additive 10V PWM signal (frequency range 300Hz~3KHz):
|
---|---
Note
- Min. duty cycle of output current is about 8% and the output current is not defined when 0%< Iout<8%.
- The duty cycle of output current could drop down to 0% when dimming input is about 0Vdc or 10V PWM signal with 0% duty cycle.
- To ensure the dimming effect, total power must be over 45W at 100% duty cycle.
OUTPUT LOAD vs TEMPERATURE
STATIC CHARACTERISTIC
※ De-rating is needed under low input voltage.
POWER FACTOR (PF) CHARACTERISTIC
TOTAL HARMONIC DISTORTION (THD)
※ 60V Model
EFFICIENCY vs LOAD
IDPV-65 series possess superior working efficiency that up to 90% can be
reached in field applications.
※ 60V Model
BLOCK DIAGRAM
fosc : 70-150KHz
MECHANICAL SPECIFICATION
※ Blank-Type
Unit:mm
Terminal Pin No. Assignment(TB1)
Pin No. | Assignment |
---|---|
1 | ACL |
2 | ACL |
3 | ACN |
4 | ACN |
Terminal Pin No. Assignment(TB2)
Pin No. | Assignment |
---|---|
1 | DIM+ |
2 | DIM- |
3 | Vo+ |
4 | Vo- |
※ A-Type
Terminal Pin No. Assignment(TB1)
Pin No. | Assignment |
---|---|
1 | ACL |
2 | ACL |
3 | ACN |
4 | ACN |
Terminal Pin No. Assignment(TB2)
Pin No. | Assignment | Pin No. | Assignment |
---|---|---|---|
1 | DIM+ | 4 | Vo- |
2 | DIM- | 5 | AUX+ |
3 | Vo+ | 6 | AUX |
INSTALLATION MANUAL
Please refer to: http://www.meanwell.com/manual.html
File Name:IDPV-65-SPEC 2022-02-18
Read User Manual Online (PDF format)