Features

  • Constant Voltage PWM style output with frequency 1 KHz
  • PCB type design
  • Built-in active PFC function
  • No load power consumption<0.5W
  • Function options: 2 in 1 dimming (dim-to-off); Auxiliary DC output
  • 3 years warranty

Applications

  • LED strip lighting
  • Indoor LED lighting
  • LED decorative lighting
  • LED architecture lighting

GTIN CODE

MW Search. haps://www.meanwell.corniserviceGTIN.aspx

Description

IDPV-65 series is a 65W PCB type AC/DC LED driver featuring the constant voltage mode PWM style output design. IDPV-65 operates from 180-295VAC and offers models with different rated voltages ranging between 12V and 60V. Thanks to the high efficiency of up to 90%, with the fanless design, the entire series is able to operate for -20 C-+40 C ambient temperature under free air convection. IDPV-65 is equipped with various function options, such as dimming methodologies, so as to provide design flexibility for the LED lighting systems.

Model Encoding

Type Function
Blank 2 in 1 dimming (0-10VDC and 10V PWM)
A 2 in 1 dimming and Auxiliary DC output

SPECIFICATION

MODEL IDPV-650-12 ippv.650-24 DPV-6036 IDPV-6C-48 IDPV-61:1-60
OUTPUT DC VOLTAGE 12V 24V 36V 48V
RATED CURRENT 4.2A 2.4A 1.8A 1.35A 1.08A
RATED POWER 50.4W 57.6W 64.8W 64.8W 64.8W
DIMMING RANGE 0-100%
VOLTAGE TOLERANCE ± 10%
PWM FREQUENCY (Typ.) 1KFtz(± 20%)
SETUP TIME Note.3 500ms /230VAC
AUXILIARY DC OUTPUT Nob/ Nominal 12V(deviation 11.4-12.6)@50mA forA-Type

only
INPUT| VOLTAGE RANGE Note.2| 180 – 295VAC          254 – 417VDC

(Please refer to ‘STATIC CHARACTERISTIC’ section)

FREQUENCY RANGE| 47 – 63Hz
POWER FACTOR crypt.)| PF>0.95/230VAC, PF>0.9/277VAC@ifull load

(Please refer to the ‘POWER FACTOR (PF) CHARACTERISTIC’ section)

TOTAL HARMONIC DISTORTION| THD< 20%(@loadM0%/230VAC; @load.475%/277VAC) (Please refer to “TOTAL HARMONIC DISTORTION’ section)
EFFICIENCY (Typ.)| 85%| I87%| I 88%| I 89%| I90%
AC CURRENT (Typ.)| 0.4A/230VAC          0.3A/277VAC
INRUSH CURRENT(Typ.)| COLD START 30A(twidth=270ps measured at 50% (peak) at 230VAC: Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 32 units (circuit breaker of type B)/ 32 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.75mA/ 277VAC
NO LOAD POWER CONSUMPTION| <0.5W
PROTECTION| SHORT CIRCUIT| Shutdown 0/P voltage, re-power on to recovery
OVER CURRENT| 105 -115%
Protection type : Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT| WORKING TEMP.| Ta=-20 – +40 C (Please refer to” OUTPUT LOAD vs TEMPERATURE’ section)
WORKING HUMIDITY| 20 – 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 – +80°C, 10 – 95% RH
TEMP. COEFFICIENT| ±0.03%/C (0 – 40°C)
VIBRATION| 10 – 500Hz, 2G 10min./Tricycle, period for 60min . each along X. Y. Z axes
SAFETY & EMC| SAFETY STANDARDS| UL8750.CSA C22.2 NO.250.13-12;ENEC EIS EN/ EN61347-1 & BS EN!EN61347-2-13 independent, BS EN!EN62384approved
WITHSTAND VOLTAGE| I/P-0/P:3.75KVAC
ISOLATION RESISTANCE| I/P-0/P:100M Ohms / 500VDC / 25°Ci 70% RH
EMC EMISSION| Compliance to BS E N/E N55015, BS E N/EN61000-3-2 Class C (tRbad:=60%); BS EN/EN61000-3-3
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547.1ight industry level(surge immunity: Lthe-Line:1KV)
OTHERS| MTBF| 3720.1K hrs min.        Telcordia SR-332 (Bellcore); 398.8K hrs min.         MIL-HDBK-217F (25°C)
DIMENSION| 130’67.5’22mm (L’IN*F1)
PACKING| 0.15Kg;81pcs/13Kg/ 1.46CUFT
NOTE| 1.  All parameters NOT specially mentioned we measured at 230VAC input, rated current, and 25’C of ambient temperature.
2.  Deleting may be needed under low input voltages. Please refer to b ‘STATIC CHARACTERISTIC’ sections tar details.
3.  Length of setup time is measured at cold first start. Turning OWOFF the driver may lead to an increase in the setup __ time.
4.  Aux. 12V will be damaged with a short circuit It will not be available with dimming off or output no load condition.
5.  The (liver is considered a component that a be operated in combination with final equipment Since EMC performance will be affected by the complete installation. the final equipment manufacturers must requalify EMC Directive on the complete installation again.
※ Product Liability Disclaimer: For detailed information, please refer to https://www.meamwell.con/servicedisclaimer.aspx

DIMMING OPERATION

※ Dimming principle for PWM style output

  • Dimming is achieved by varying the duty cycle of the output current.

※ 2 in 1 dimming function
◎ Applying additive 0 ~ 10VDC

◎ Applying additive 10V PWM signal (frequency range 300Hz~3KHz):

|
---|---

Note

  1. Min. duty cycle of output current is about 8% and the output current is not defined when 0%< Iout<8%.
  2. The duty cycle of output current could drop down to 0% when dimming input is about 0Vdc or 10V PWM signal with 0% duty cycle.
  3. To ensure the dimming effect, total power must be over 45W at 100% duty cycle.

OUTPUT LOAD vs TEMPERATURE

STATIC CHARACTERISTIC

※ De-rating is needed under low input voltage.

POWER FACTOR (PF) CHARACTERISTIC

TOTAL HARMONIC DISTORTION (THD)

※ 60V Model

EFFICIENCY vs LOAD
IDPV-65 series possess superior working efficiency that up to 90% can be reached in field applications.
※ 60V Model

BLOCK DIAGRAM

fosc : 70-150KHz

MECHANICAL SPECIFICATION

※ Blank-Type

Unit:mm

Terminal Pin No. Assignment(TB1)

Pin No. Assignment
1 ACL
2 ACL
3 ACN
4 ACN

Terminal Pin No. Assignment(TB2)

Pin No. Assignment
1 DIM+
2 DIM-
3 Vo+
4 Vo-

※ A-Type

Terminal Pin No. Assignment(TB1)

Pin No. Assignment
1 ACL
2 ACL
3 ACN
4 ACN

Terminal Pin No. Assignment(TB2)

Pin No. Assignment Pin No. Assignment
1 DIM+ 4 Vo-
2 DIM- 5 AUX+
3 Vo+ 6 AUX

INSTALLATION MANUAL

Please refer to: http://www.meanwell.com/manual.html

File Name:IDPV-65-SPEC 2022-02-18

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals