signify Lumec DM50 ClassicStyle Outdoor Urban Bollard User Guide
- June 5, 2024
- signify
Table of Contents
- signify Lumec DM50 ClassicStyle Outdoor Urban Bollard
- Ordering guide
- Urban Luminaire
- Driver Option Details
- Motion Response Details
- Bollard Options Details
- Predicted Lumen Depreciation Data
- LED light engine technical information for ClassicStyle Bollard (VBR)
- Specification
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
signify Lumec DM50 ClassicStyle Outdoor Urban Bollard
ClassicStyle outdoor urban bollard luminaires feature ClearGuide, a revolutionary, vertically-oriented light engine designed to reduce pixelation and glare
Ordering guide
- Luminaire always shipped with a dimmable 0-10V driver
- 0-10 volt and all driver options not available.
- MR is Not available with Driver nor OVR options.
- House Side Shield is only available with Type 3.
- MR Option not available.
Urban Luminaire
**Dimensions
**
Bolt Circle Pattern
Driver Option Details
Dynadimmer Profiles
Ordering Code|
Scenario
|
Dimming Time
|
Dimming Level
---|---|---|---
DS25| Safety| 4 hours| 25% power dimming
DS50| Safety| 4 hours| 50% power dimming
DS75| Safety| 4 hours| 75% power dimming
DM25| Median| 6 hours| 25% power dimming
DM50| Median| 6 hours| 50% power dimming
DM75| Median| 6 hours| 75% power dimming
DE25| Economy| 8 hours| 25% power dimming
DE50| Economy| 8 hours| 50% power dimming
DE75| Economy| 8 hours| 75% power dimming
DCP| Programmable| Determined by user| Determined by user
-
CLO: Pre-set driver to manage the lumen depreciation by adjusting the power given to the LEDs offering the same lighting intensity during the
the entire lifespan of the LED module. -
AST: Pre-set driver for the progressive start-up of the LED module(s) to optimize energy management and enhance visual comfort at start-up.
-
OTL: Pre-set driver to signal the end of life of the LED module(s) for better fixture management.
-
DALI: Pre-set driver compatible with the DALI control system.
Motion Response Details
PIR Sensors are able to detect motion in the appropriate patterns shown below
MR
Motion Response Option Detail
Note: Motion Sensors rely on special zonal crossings to detect motion. It is possible for a person to directly approach the bollard motion sensor without crossing between zones until 15′ from the motion sensor. The actual motion detection distance may vary based on specific application characteristics.
Bollard Options Details
HS
House Side Shield Factory installed only.
PH7
Button Eye Photocell
Predicted Lumen Depreciation Data
Predicted performance derived from LED manufacturer’s data and engineering design estimates, based on IESNA LM-80 methodology. Actual experience may vary due to field application conditions.L70 is the predicted time when LED performance depreciates to 70% of initial lumen output. Calculated per IESNA TM21-11. Published L70 hours limited to 6 times actual LED test hours
Ambient Temperature °C| Driver mA| Calculated L70 Hours| L70 per TM-21| Lumen
Maintenance % at 60,000 hrs
---|---|---|---|---
25°C| up to 350 mA| >100,000 hours| >60,000 hours| >96%
LED light engine technical information for ClassicStyle Bollard (VBR)
CCT = 4000K nominal (3985K +/- 275K), CRI = 70, System (LED + driver) rated life = 100,000 hrs 1
LED
Module
|
Typically delivered lumens
| Typical system wattage (W)2| Typical System Current (A) @|
LED
current (mA)
|
HID 3 equivalent
| Luminaire Efficacy Rating (Lm/W)|
BUG
rating
---|---|---|---|---|---|---|---
120V| 208V| 240V| 277V| 347V| 480V
CCT = 3000K nominal (3045K +/- 175K), CRI = 70, System (LED + driver) rated life = 100,000 hrs 1
LED
Module
|
Typically delivered lumens
| Typical system wattage (W)2| Typical System Current (A) @|
LED
current (mA)
|
HID 3 equivalent
| Luminaire Efficacy Rating (Lm/W)|
BUG
rating
---|---|---|---|---|---|---|---
120V| 208V| 240V| 277V| 347V| 480V
- L70 = 70,000 hrs (at ambient temperature = 25°C)
- System wattage includes the lamp and the LED driver
- Equivalence should always be confirmed by a photometric layout
Note: Due to rapid and continuous advances in LED technology, LED luminaire data is subject to change without notice and at the discretion of Signify
Specification
Hood
Built-in the heat sink shall be made from cast aluminum 356 optimizing the
Led’s efficiency and life. The product does not use any cooling device with
moving parts (only passive cooling device). Hood, globe, and cage are held
together with the help of central tubing.
Cage
In a round shape with 4 arms, this cage is a one-piece cast 356 Aluminum alloy
0.250 (6.4mm) minimum thickness, mechanically assembled to the base.
Light Engine
ClearGuide technology, use a light guide to create a clear transparent visual
appearance during the day while achieving comfortable uniform light at night.
Composed of 4 main components: Heat Sink / LED Module / Optical System /
Driver Electrical components are RoHS compliant, LEDs tested by ISO 17025 2005
accredited lab in accordance with IESNA LM 80 guidelines in compliance with
EPA ENERGY STAR, extrapolations in accordance with IESNA TM 21. A metal core
board ensures greater heat transfer and a longer lifespan.
Globe
Made of one‑piece seamless injection‑molded clear polycarbonate. The globe is
assembled between the hood and the cage and is rated IP66. Tested in
accordance with CEI 62262 standard, globe is rated IK10.
LED Module
Composed of 15 high-performance white LEDs. Color temperature as per ANSI bin
Neutral White, 3000 Kelvin nominal (3045K +/ 175K) or 4000 Kelvin nominal
(3985K +/ 275K), CRI 70 Min. 75 Typical.
Optical System
ClearGuide technology (3-5), IES type III-V (asymmetrical symmetrical).
Composed of high-performance optical grade molded PMMA (polymethyl
methacrylate) acrylic light guide with precision rings provides superior
optical control to achieve desired distribution optimized to get the maximum
spacing and target lumens. Use of ClearGuide technology optics for optimal
light distribution without direct view of the LEDs. This system provides glare
control, visual comfort, and facial recognition for safety and creates light
designed for vertical uniform illumination to the environment. Performance
shall be tested per LM 63, LM 79, and TM 15 (IESNA) certifying its photometric
performance. Street side indicated
Driver
High power factor >90%. Electronic driver, operating range 50/60 Hz. Auto
adjusting universal voltage input from 120 to 277 VAC rated for both
application line to line or line to neutral, Class I, THD <20%. Maximum
ambient operating temperature from 40F( 40C) to 130F(55C) degrees. Certified
in compliance with UL1310 cULus requirement. Dry and damp location. Values are
based on 120 volts. The driver comes with dimming compatible 0-10 volts.
Driver with MR: High power factor >90%. Electronic driver, operating
range 50/60 Hz. Auto adjusting universal voltage input from 120 to 277 VAC
rated for both application line to line or line to neutral, Class II, THD
<20%. Maximum ambient operating temperature from 40F( 40C) to 130F(55C)
degrees. Certified in compliance with UL1310 cULus requirement. Dry and damp
location. Values based on 120 volt. Driver comes with dimming compatible 0 10
volts.The current supplying the LEDs will be reduced by the driver if the
driver experiences internal overheating as a protection to the LEDs and the
electrical components. Output is protected from short circuits, voltage
overload and current overload. Automatic recovery after correction. Standard
built in driver surge protection of 2.5kV (min).
Surge Protection
Surge protector tested in accordance with ANSI/IEEE C62.45 per ANSI/IEEE
C62.41.2 Scenario I Category C High Exposure 10kV/10kA waveforms for Line
Ground, Line Neutral, and Neutral Ground, and in accordance with U.S. DOE
(Department of Energy) MSSLC (Municipal Solid-State Street Lighting
Consortium) model specification for LED roadway luminaires electrical immunity
requirements for High Test Level 10kV / 10kA.
SP2 Option: Integral surge protector tested in accordance with ANSI/IEEE
C62.45 per ANSI/IEEE C62.41.2 Scenario I Category C High Exposure with
elevated 20kV/20kA waveforms for Line-Ground, Line-Neutral and Neutral-Ground,
and in accordance with U.S. DOE (Department of Energy) MSSLC (Municipal Solid-
State Street Lighting Consortium) model specification for LED roadway
luminaires electrical immunity requirements for High Test Level 10kV / 10kA.
Access-Mechanism
Two integrated captive screws offer access to the inside of the base by
pulling up the bollard’s entire top. This system includes a secured blocking
device holding screws in a locking position.
Base
Made of cast aluminum 356, mechanically assembled to the anchor plate.
Base Cover
Two pieces of round base cover made from cast 356 aluminum, mechanically
fastened to the base.
Quality Control
The manufacturer must provide written confirmation of its ISO 9001 2008 and
ISO 14001 2004 International Quality Standards Certification.
Bollard Options
PH7: Button type photocell. The connection did on-site by others.
MR: Motion Response includes two (2) Panasonic EKMB1203112 Passive
Infrared (PIR) sensors to detect motion. When motion is not detected for a
5-minute period, bollards automatically dim to 20% power and light, gradually
over a 2-minute period. Once Motion is detected, the bollard immediately ramps
to full power and light output until motion is not detected for a 5-minute
period. See the end of the document for more information on Motion Response.
SP2: Integral surge protector tested in accordance with ANSI/ IEEE C62.45
per ANSI/IEEE C62.41.2 Scenario I Category C High Exposure with elevated
20kV/20kA waveforms for Line-Ground, Line-Neutral and Neutral-Ground, and in
accordance with U.S. DOE (Department of Energy) MSSLC (Municipal Solid-State
Street Lighting Consortium) model specification for LED roadway luminaires
electrical immunity requirements for High Test Level 10kV / 10kA.
Luminaire Useful Life
Refer to IES files for energy consumption and delivered lumens for each
option. Based on ISTMT in situ thermal testing in accordance with UL1598 and
UL8750, System Reliability Tool, Advance data, and Lumileds LM-80/TM-21 data,
expected to reach 100,000 + hours with >L70 lumen maintenance @ 25°C.
Luminaire Useful Life accounts for LED lumen maintenance AND all of these
additional factors including LED life, driver life, PCB substrate, solder
joints, on/off cycles, burning hours, and corrosion. The entire luminaire is
rated for operation in the ambient temperature of -40°C / -40°F up to +35°C /
+95°F.
LED products manufacturing standard
The electronic components sensitive to electrostatic discharge (ESD) such as
light emitting diodes (LEDs) are assembled in compliance with IEC61340 5 1 and
ANSI/ESD S20.20 standards so as to eliminate ESD events that could decrease
the useful life of the product.
Quality Control
The manufacturer must provide written confirmation of its ISO 9001 2008 and
ISO 14001 2004 International Quality Standards Certification.
Hardware
All exposed screws shall be complete with Ceramic primer‑seal basecoat to
reduce seizing of the parts and offers high resistance to corrosion. All seals
and sealing devices are made and/or lined with EPDM and/or silicone and/or
rubber.
Finish
In accordance with the AAMA 2603 standard. Application of polyester powder
coat paint (4 mils/100 microns) with ± 1 mil/24 microns of tolerance. The
Thermosetting resins provides a discoloration resistant finish in accordance
with the ASTM D2244 standard, as well as luster retention in keeping with the
ASTM D523 standard and humidity proof in accordance with the ASTM D2247
standard. The surface treatment achieves a minimum of 2000 hours for salt
spray resistant finish in accordance with testing performed and per ASTM B117
standard.
Certifications and Compliance
CSA, cULus Listed for Canada and USA.
Related Families
ClassicStyle Post Top LED (VLR)
©2022 Signify Holding. All rights reserved. This document may be subject to
change. No representation or warranty as to the accuracy or completeness of
the information included herein is given and any liability for any action in
reliance thereon is disclaimed. All trademarks are owned by Signify Holding or
their respective owners. Signify North America Corporation 400 Crossing Blvd,
Suite 600, Bridgewater, NJ 08807 Telephone
855-486-2216
References
Read User Manual Online (PDF format)