SilkSpace
Recessed LED
Installation Instructions
ID-42_SilkSpace_recessed
Standalone Configurations
System Overview—Standalone
These instructions review how to install standalone SilkSpace recessed
fixtures.
Please refer to layout drawings supplied by Ledalite in conjunction with these
installation instructions.
The graphics below show the steps required to correctly install standalone
SilkSpace luminaires in T-Grid ceilings.
IMPORTANT: Read all instructions including fixture wiring AND mechanical
details before beginning installation.
-
Prepare fixtures
Arrange boxed fixtures on the floor in specified mounting locations; remove fixtures from boxes. • Lift using both hands from fixture ends only
• Do not use cross-strap to lift fixture (2×4, 2×4) -
Remove from Packaging Remove luminaire from packaging, recycle box.
-
Install in ceiling grid Lift and shift luminaire into T-grid. Bend mounting tabs flush against outside of T-grid.
-
Secure luminaire and Tie off to structure Secure luminaire to T-grid with self drilling 8×1/4” sheet metal screws (supplied by others).
Secure luminaire with grid wire or suitable equivalent per local and national building codes. -
a Standalone wiring Remove pre-installed wire access plate. Connect power feed to the leads provided. Reinstall wire access plate.
5b. Flex Whip (Optional) Optional Flex Whip is prewired to the fixture.
Insert wire access plate into wiring cavity. Complete electrical connection at other end of whip in accordance with local and national building code.
System Overview—Continuous Runs
These instructions review how to install continuous row SilkSpace recessed
fixtures.
Please refer to layout drawings supplied by Ledalite in conjunction with these
installation instructions. The graphics below show the steps required to
correctly install continuous row SilkSpace luminaires in T-Grid ceilings.
IMPORTANT: Read all instructions including fixture wiring AND mechanical
details before beginning installation.
1. Prepare fixtures
Arrange boxed fixtures on the floor in specified mounting locations; remove
fixtures from boxes.
• Lift using both hands from fixture ends only
• Do not use cross-strap to lift fixture (2×4, 2×4)
2. Remove from Packaging Remove luminaire from packaging, recycle box.
3. Install in ceiling grid Lay luminaire into T-grid. Bend mounting tabs
flush against outside of T-grid.
4. Secure luminaire and Tie off to structure Secure luminaire to T-grid
with self drilling 8×1/4” sheet metal screws (supplied by others).
Secure luminaire with grid wire or suitable equivalent per local and national
building codes.
5. Remove driver top cover Remove pre-installed wire access plate.
Connect power feed to the leads provided. Reinstall wire plate access.
6. Attach adjacent fixtures
Remove connecting knock-outs and attach adjacent fixtures to the T-grid
following steps 1-5.
Place a 1/2″ nipple through the knock-out hole between the fixtures. Fasten
with a 1/2″ NPT lock nut (nipple and lock nut supplied by others).
Mounting in a drywall ceiling
7. Drywall ceiling cut outCut a hole in the drywall width according to the
dimensions in the table above.
8. Installing mounting frame Insert mounting frame into hole and secure as
shown in step 9.
9. Mounting options Secure mounting frame by screwing to wood frame
or attaching hanger wires.
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the F CC Rules. These limits are
designed to provide reasonable protection against harmful interreference when
the equ ipment is operated in a commercial environment. This equipme nt
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which case
the user will be required to correct the int erference at his own expense.
ATTENTION: Install in accordance with national and local building and
electrical codes.
© 2023 Signify Holding. All rights are reserved.
Reproduction in whole or part is prohibited without the written consent of the
copyright owner.
Phone: 604.888.681 | Web:
ledalite.com/products Rev D November 21, 2023
Signify North America Corporation. 400 Crossing Blvd, Suite 600
Bridgewater, Nj 08807. Telephone:
855-486-2216 Signify Canada Ltd.
281 Hillmount Road, Markham, ON, Canada L6C 253.
Telephone: 800-668-9008
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>