signify 442296094811 EvoSeal Recessed Delivers Innovative Healthcare Lighting Instructions

May 15, 2024
signify

signify 442296094811 EvoSeal Recessed Delivers Innovative Healthcare

Lighting

signify-442296094811-EvoSeal-Recessed-Delivers-Innovative-Healthcare-
Lighting-product

Specifications

  • Product Name: EvoSeal
  • Classification: Classified
  • Mounting: Recessed
  • Sizes Available: 1×4, 2×2, 2×4
  • Model Number: 442296094811

Product Usage Instructions

Tools / Accessories Needed (Not Included): Drill bit

Tools / Accessories Needed (Included):

  • Self-drilling screws
  • T-Bar
  • Access Plate
  • End Plate

It is recommended to have two persons for the installation process.

CAUTION: The installation and servicing of this product should be performed by a qualified electrician or service personnel.

  1. Step 1: Install Luminaire Place the luminaire at the T-bar location.
  2. Step 2: Make Supply Connections Connect the supply through the access plate provided in the luminaire.
  3. Step 3: Put Clips on T-Bar Slide the clips upwards on the T-bar so that they are in contact with the T-bar lance.
  4. Step 4: Secure Luminaire Push the luminaire slightly downwards to create a seal between the gasket and T-bar.
  5. Step 5: Secure with Self-Drilling Screws While keeping the luminaire pushed down, place self-drilling screws in the clips to secure the luminaire.

Frequently Asked Questions

  • Q: Can the EvoSeal luminaire be installed by a non-professional?
    • A: No, it is recommended that installation be performed by a qualified electrician or service personnel.
  • Q: What is the importance of achieving an IP65 rating during installation?
    • A: Achieving an IP65 rating ensures the luminaire’s protection against dust and water ingress, is suitable for outdoor or damp environments.

CAUTION: THE INSTALLATION AND SERVICING OF THIS PRODUCT SHOULD BE PERFORMED BY A QUALIFIED ELECTRICIAN OR SERVICE PERSONNEL
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital service, pursuant to Part 15 of the FFC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Tools/accessories needed

  • (1) ¼ electric screwdriver
  • (1) ¼ bit for an electric screwdriver (recommended to use a magnetic bit)

Tools/accessories needed (included):

  • Self-drilling screws

It is suggested to make the installation with two personssignify-442296094811-EvoSeal-Recessed-Delivers-Innovative-Healthcare-
Lighting-fig-1

Installation Instruction

FOR THE IP65 RATING TO BE ACHIEVED THE LUMINAIRE MUST BE INSTALLED ACCORDING TO INSTRUCTIONS GIVEN FROM STEP 1 TO STEP 5. TO CONFIRM THE CORRECT INSTALLATION OF THE LUMINAIRE, CHECK THAT THE LUMINAIRE DOES NOT MOVE UP AND DOWN ONCE THE CLIPS ARE INSTALLED

Step 1

  • Install the Luminaire by placing at the T-bar location, as shown in figure 1.signify-442296094811-EvoSeal-Recessed-Delivers-Innovative-Healthcare-Lighting-fig-2

Step 2

  • Make supply connections through access plate provided in the luminaire, as shown in Figure 2.Asignify-442296094811-EvoSeal-Recessed-Delivers-Innovative-Healthcare-Lighting-fig-3

Note: In some configurations, the location of the access plate may changesignify-442296094811-EvoSeal-Recessed-Delivers-Innovative-Healthcare-
Lighting-fig-4

Note: Grounding Detail

  • Grounding conductor (Up insulated) to be strip min. 1 .
  • Insert the end of the wire into small hole
  • Wrap counterclockwise as illustrated
  • Tighten screw, as shown in figure 2.C

Step 3

  • Put the clip at the T-Bar and slide the clips upwards in such a way that the lance in the clip is in contact with the t- bar, as shown in figure 3.A and 3.B.
  • Note: This step must be done once the luminaire is placed in the T-bar.signify-442296094811-EvoSeal-Recessed-Delivers-Innovative-Healthcare-Lighting-fig-6

Step 4

While Keeping the clip in the position described in the previous step, push the luminaire slightly downwards to achieve a better seal between the luminaire gasket and the T-bar, as shown in figure 4.

Step 5

  • While pushing the luminaire down and keeping the clip in position place the self-drilling screw in any hole available in the clip, as shown in figure 5.
  • Note: It is necessary to drill a new hole through the end plate for clips installation. The self-drilling screws are included. Repeat steps 3 and 4 on each corner of the luminaire.signify-442296094811-EvoSeal-Recessed-Delivers-Innovative-Healthcare-Lighting-fig-8

© 2021 Signify Holding. All rights reserved. The information provided herein is subject to change, without notice. Signify does not give any representation or warranty as to the accuracy or completeness of the information included herein and shall not be liable for any action in reliance thereon. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract unless otherwise agreed by Signify.

Contact

Signify North America Corporation

  • 400 Crossing Blvd, Suite 600
  • Bridgewater, NJ 08807, USA
  • Telephone 855-486-2216

Signify Canada Ltd.

  • 281 Hillmount Road,
  • Markham, ON, Canada L6C 253
  • Telephone 800-668-9008

All trademarks are owned by Signify Holding or their respective owners.