signify BoldPlay Wall Benchmark For LED Luminaires
Specifications:
- Product Name: BoldPlay Wall
- Configuration: Standalone or continuous run
- Module Lengths: 4ft, 8ft
Product Usage Instructions
Installation Overview:
The BoldPlay wall mount fixtures can be installed individually as
standalone units or joined together to create continuous rows.
Required Tools:
- Phillips screwdriver
- 3/8 nut driver
-
2 Robertson/Flat screwdriver
Installation Steps:
-
Step 1: Install Utility Box and Cover Plate
Attach the cover plate to the utility box and secure it to the wall structure parallel to the fixture. Make power connections at the utility box and attach the cover using supplied hardware. -
Step 2: Install Wall Brackets
Secure the wall brackets to the wall structure ensuring they are properly aligned for fixture installation. -
Step 3: Unpack and Prepare Fixtures
Arrange fixtures in specified locations, remove from boxes, and remove any packaging material. Cap unnecessary power feed holes at the back of the fixture. -
Step 4a: Remove Top Reflector
Shift the top reflector to the left and remove it from the fixture. -
Step 4b: Remove Front Reflector
Remove the front reflector by unscrewing it from the fixture. -
Step 5: Raise Fixture and Engage on Wall Brackets
With the help of two people, lift the fixture into position and hook it onto the wall brackets. Secure the bracket using supplied hardware. -
Step 6: Prepare Wiring
Follow the wiring instructions provided in the manual to connect the fixture to the power source.
Frequently Asked Questions (FAQ):
-
Q: Can the BoldPlay wall mount fixtures be used outdoors?
A: No, these fixtures are designed for indoor use only. -
Q: What is the maximum row length that can be achieved by combining modules?
A: The tables provided in the manual indicate that various lengths can be achieved by combining 4ft and 8ft modules up to a maximum of 32 feet.
Installation Instructions
ID_7808_BoldPlay_Wall_LED
Standalone or continuous run configurations
System Overview
- These instructions review how to install BoldPlay wall mount fixtures. BoldPlay 4 ft and 8 ft modules can be installed as individual standalone units, or they can be joined together to create continuous rows. The graphic below shows the components required to install a typical row of BoldPlay wall mount fixtures.
- IMPORTANT: Read all instructions including fixture/sensor wiring AND mechanical details before beginning installation.
TOOLS REQUIRED: Phillips screwdriver, 3/8 ” nut driver and #2 Robertson/Flat screwdriver.
-
Module Lengths
BoldPlay wall mount systems come in 4ft and 8ft modules. Overall module lengths are shown to the right. Module lengths do not include endcaps. -
Endcaps
Add two endcaps to the length of each run.
Mount Spacing
- Mounts variable within 2″ – 5″ of end or joint. On 8ft module, additional mount to be located within 2″ – 5″ of center of module.
- Maximum distance between mounts is 48″. Note: Fixture is flush with wall.
Row Configurations
The tables below indicate how 4ft and 8ft modules can be combined to create
continuous rows of various lengths.
Nominal row length | 4ft module | 8ft module |
---|---|---|
4′ | 1x | |
8′ | 1x | |
12′ | 1x | 1x |
16′ | 2x | |
20′ | 1x | 2x |
24′ | 3x | |
28′ | 1x | 3x |
32′ | 4x |
ATTENTION: Install in accordance with national and local building and electrical codes.
Installation Instructions
ID_7808_BoldPlay_Wall_LED
IMPORTANT: Read all instructions at least once prior to beginning
installation. All mount brackets must be secured to wall structure (eg. studs
or cross-braces).
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
-
Determine power feed location and install 2″x4″ utility box (supplied by others) parallel with fixture. Complete connections at utility box with supplied power cord. Attach cover bracket using supplied hardware. Punch power access hole in supplied cover, feed power cord through and attach strain relief on wall side. Attach cover using supplied painted hardware.
NOTE: Bottom of utility box should be in line with bottom of wall brackets. -
Determine fixture mounting location and secure wall brackets to structure using appropriate fasteners (two per bracket, supplied by others). 4ft fixtures: Require two bracket assemblies; 8ft fixtures: Require three bracket assemblies. Brackets must be installed a maximum of 5″ from end of fixture (on 8ft fixture, the third bracket can be 5″ of ether side of in row cross plate).
NOTE: Mounted fixture(s) will sit approximately /4″ above top edge of bracket assembly. -
3 Unpack / Prepare fixtures
Arrange boxed fixtures on floor in specified locations; remove fixtures from boxes; remove plastic from fixtures. Cap all unnecessary power feed holes at back of fixture(s) using supplied /2″ plugs. -
Shift top reflector to the left and then remove the reflector.
-
Remove the screws holding the front reflector and then remove the front reflector.
-
With 2 people, raise fixture into position and engage it on hooks located on top of wall brackets, then rotate it down into position. Secure bracket using supplied hardware.
POWER LOCATIONS: Prior to engaging fixture in mounting brackets, feed installed power cord through the access hole at back of the fixture. -
Route SVT cord through back rail, through the /2 bushing and into the wiring cavity. Install strain relief.
-
Complete electrical connections using wire nuts (supplied by others). Tuck wires back into cavity.
-
LEVEL : Using 5/ 6″ hex nut driver, level fixture by adjusting the tilt screw.
SECURE: Secure fixture to wall bracket assemblies by tightening the lock screw. -
With two people, raise second fixture and engage on mounting brackets (see STEP 4). At joint, remember to insert black gasket.
-
Complete in-row electrical connections.
- NON-POWER LOCATIONS: Use supplied quick-wire connectors. Tuck wires into wire cavity.
- POWER LOCATIONS: Remove installed quick-wire connectors and complete electrical connections using wire nuts (supplied by others). Tuck wires into wiring cavity.
- NOTE: Use smallest appropriate wire nuts.
-
Level second fixture by adjusting the tilt screw (see step 8). Slide second fixture flush against first fixture and secure joint using supplied nut and bolt hardware (requires 3/8″ nut drivers). Secure fixture to wall brackets by tightening the lock screw at each bracket location (see step 8).
Repeat steps 8- 0 for each additional fixture(s) in row. -
Attach endcap to first and last module in each row using supplied hardware.
IMPORTANT: Do not over-tighten endcap fasteners. Ledalite recommends tightening fasteners by hand. When nut is flush with crossplate, turn an additional 1/4 turn. -
Re-install front reflector.
-
Identify smooth side of the Light Guide and ensure it is installed smooth side DOWN.
- Install Light Guide panel into LED fixture after joining and wiring is complete. Ensure panel is seated correctly as shown above.
- Final Step: Install the top reflector and shift into place.
Sensor in Rows
Single Sensor Controlling Whole Row
-
Purple & brown (or purple & grey/pink) control wires MUST be connected between fixtures. Note :
A maximum of 8 drivers can be wired to 8 sensors; confirm fixture driver count with factory. -
Multiple Sensors Controlling Separates Zones in a Row
-
Purple & brown (or purple & grey/pink) control wires MUST NOT be connected between zones.
Notes : -
A maximum of 8 drivers can be wired to one sensor; confirm fixture driver count with factory.
-
Only one sensor is allowed on a wired zone. (Sensors can be paired together wirelessly via a mobile app).
Sensor Spacing
- For correct operation, sensor should be placed a minimum distance of 8ft apart.
- Wireless sensor should be placed no further than 40ft apart for good wireless signal connection.
Important Consideration When Using Sensor in a Row
For fixtures with wireless sensors (CS, SB or RA options):
- DO NOT connect fixture purple and brown (or purple & grey/pink) control wires to an external dimming switch. Fixture mains wiring should not be connected to a circuit with an external on/off switch.
- For best aesthetic condition, place sensors at ends of row only so as not to break the continuous lens.
- For better occupancy coverage in longer rows, sensors may be placed mid run, but keep in mind this will break the continuous lens into discrete sections. Alternatively, remote sensors may be used, note the same wiring rules will apply.
Occupancy Sensor Coverage:
Note: Longer dimension of detection area (Y1, Y2) is parallel to longer
dimension of the luminaire.
Daylight Sensor
- The light sensor measures the total amount of light in a circular field of approximately 80% of the PIR detection area. The following aspects should be observed during installation:
- Minimum distance from the window = 2ft (0.6m).
- Prevent light reflections from outside entering the sensor (for example sunlight reflection on a car hood) as this will lead to incorrect light regulation.
- As a guideline the formula 0.72 X H can be used to calculate the minimum distance between the window and sensor whereby H is the height from the bottom of the window to the sensor.
The detection area for the movement sensor can be roughly divided into two parts;
- Minor movements (person moving = 3ft/s or 0.9m/s).
- Major movements (person moving = 3ft/s or 0.9m/s).
Photosensor spatial response
© 2023 Signify Holding. All rights are reserved. Reproduction in whole or part is prohibited without the written consent of the copyright owner.
- Phone: 604.888.6811
- Web: ledalite.com/products