Product Information
Specifications
- Model: HRP-300N series
- Output Power: 300W
- Input Voltage Range: 85~264VAC
- Output Voltage Options: 12V, 24V, 36V, 48V
- Efficiency: Up to 89%
- Protections: Short circuit, Overload, Over voltage, Over temperature
- Features: Active PFC function, Built-in cooling fan, Remote sense function
- Warranty: 5 years
Product Usage Instructions
Installation
-
Ensure the input voltage matches the specified range (85~264VAC).
-
Select the appropriate output voltage (12V, 24V, 36V, or 48V) based on your application requirements.
-
Connect the power supply to your industrial automation
machinery or control system following proper electrical wiring standards. -
Make sure to provide adequate ventilation for the power supply unit.
Operation
- Power on the unit using the ON-OFF control.
- Monitor the DC OK signal to ensure the proper functioning of the power supply.
- In case of any abnormality such as overload or over temperature, the unit will automatically shut down for protection.
Maintenance
- Regularly check for dust accumulation and clean the cooling fan to maintain optimal cooling performance.
- Inspect the power supply for any physical damage or loose connections.
- Refer to the user manual for troubleshooting steps in case of any issues.
Frequently Asked Questions
- Q: What is the warranty period for the HRP-300N series power supply?
- A: The HRP-300N series power supply comes with a warranty period of 5 years from the date of purchase.
- Q: Can the HRP-300N model withstand input voltage surges?
- A: Yes, the HRP-300N model can withstand 300VAC surge input for up to 5 seconds.
- Q: What are the typical applications of the HRP-300N power supply?
- A: The HRP-300N power supply is commonly used in industrial automation machinery, control systems, diagnostic facilities, and telecommunications equipment among others.
QR Code
Features
- Universal AC input / Full range
- Built-in active PFC function, PF>0.95
- 250% peak power capability
- High efficiency up to 89%
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Overload / Over voltage / Over temperature
- 1U low profile 41mm
- Built-in cooling fan ON-OFF control
- Built-in DC OK signal
- Built-in remote sense function
- 5 years warranty
Applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Diagnostic or biological facilities
- Test or measurement systems
- Telecommunication equipment
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
HRP-300N is a 300W single output type AC/DC power supply. This series operates for 85~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the built-in fan with fan ON-OFF control, working for the temperature up to 70°C. Moreover, HRP-300N provides 250% short-duration peak power for motor applications and electromechanical loads requiring much higher power during start-up.
Model Encoding
SPECIFICATION
MODEL| HRP-300N-12| HRP-300N-24| HRP-300N-36| HRP-
300N-48
---|---|---|---|---
OUTPUT
| DC VOLTAGE| 12V| 24V| 36V| 48V
RATED CURRENT| 27A| 14A| 9A| 7A
CURRENT RANGE| 0 ~ 27A| 0 ~ 14A| 0 ~ 9A| 0 ~ 7A
RATED POWER| 324W| 336W| 324W| 336W
RIPPLE & NOISE (max.) **Note.2| 120mVp-p| 150mVp-p| 250mVp-p| 250mVp-p
VOLTAGE ADJ. RANGE| 10.2 ~ 13.8V| 21.6 ~ 28.8V| 28.8 ~ 39.6V| 40.8 ~
55.2V
VOLTAGE TOLERANCE Note.3| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.3%| ±0.2%| ±0.2%| ±0.2%
LOAD REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at
full load
HOLD UP TIME (Typ.)**| 16ms/230VAC 16ms/115VAC at full load
INPUT
| VOLTAGE RANGE Note.4| 85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF>0.95/230VAC PF>0.99/115VAC at full
load
EFFICIENCY (Typ.)| 88%| 87%| 88%| 89%
AC CURRENT (Typ.)| 3.5A/115VAC 1.8A/230VAC
INRUSH CURRENT (Typ.)| 35A/115VAC 75A/230VAC
LEAKAGE CURRENT| <1.5mA / 240VAC
PROTECTION
| ****
OVERLOAD
| Normally works within 105 ~ 200% rated output power for more than 5 seconds
and then shut down o/p voltage, re-power on to recover
Constant current limiting for output power >280% rated for more than 5 seconds
and then shut down o/p voltage, re-power on to recover
OVER VOLTAGE
| 14.4 ~ 16.8V| 30 ~ 34.8V| 41.4 ~ 48.6V| 57.6 ~ 67.2V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, recovers automatically after
temperature goes down
FUNCTION
| DC OK SIGNAL| PSU turns on : 3.3 ~ 5.6V ; PSU turns off : 0 ~ 1V
FAN CONTROL (Typ.)| Load 35±15% or RTH2≧50℃ Fan on
ENVIRONMENT
| WORKING TEMP.| -40 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ± 0.03%/ ℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
(Note 5)
| SAFETY STANDARDS| UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004,
AS/NZS 62368.1 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION
| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032| Class B
Radiated| BS EN/EN55032| Class B
Harmonic current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY
| BS EN/EN55035 , BS EN/EN61000-6-2(BS EN/EN50082-2)
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air; Level 2, 4KV contact
RF field| BS EN/EN61000-4-3| Level 3, 10V/m
EFT/ Burst| BS EN/EN61000-4-4| Level 3, 2KV
Surge| BS EN/EN61000-4-5| Level 4, 4KV/Line-FG; 2KV/Line-Line
Conducted| BS EN/EN61000-4-6| Level 3, 10V
Magnetic Field| BS EN/EN61000-4-8| Level 4, 30A/m
Voltage Dips and Interruptions
| ****
BS EN/EN61000-4-11
| 95% dip 0.5 periods, 30% dip 25 periods,
95% interruptions 250 periods
OTHERS
| MTBF| 1529.4K hrs min. Telcordia SR-332 (Bellcore) ; 201.4K hrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 19910541mm (LWH)
PACKING| 0.9Kg;15pcs/14.5Kg/0.84CUFT
NOTE
| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re- confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Block Diagram
Derating Curve Output Derating VS Input Voltage
Function Manual
Remote Sense
The remote sensing compensates voltage drop on the load wiring up to 0.5V.
DC-OK Signal
DC-OK signal is a TTL level signal. High when PSU turns on.