MEAN WELL IRM-10 Series 10W AC and DC PCB Mount Green Power Module
Product Information
Specifications
- Product Name: 10W AC-DC PCB-Mount Green Power Module
- Series: IRM-10
- Standards: LPS, UL62368-1, BS EN/EN62368-1, R33100 RoHS, TPTC004, IEC62368-1
- Features: Bauart gepruft Sicherheit, egelma ge od o s be wac g, compact size of 1.8”x1”
- Input: Universal input 85~305VAC
- Power Consumption: No load power consumption
Product Usage Instructions
Installation
- Ensure that the power module is compatible with your device’s requirements.
- Mount the module securely on the PCB using appropriate tools.
- Connect the input wires following the polarity indicated on the module.
- Double-check all connections before powering on the device.
Powering On
- Apply power within the specified input voltage range of 85~305VAC.
- Check for any abnormal sounds or smells during initial power-up.
- If everything appears normal, proceed with using your device as intended.
Maintenance
Regularly inspect the power module for any signs of damage or overheating.
If any issues are detected, discontinue use and seek professional assistance.
Frequently Asked Questions (FAQ)
-
Q: What should I do if the power module gets hot during operation?
A: If the module feels excessively hot, immediately disconnect power and allow it to cool down before further use. Contact customer support if the issue persists. -
Q: Can I use this power module with devices that have different voltage requirements?
A: No, it is recommended to use the power module only with devices that fall within the specified input voltage range of 85~305VAC to prevent damage.
Features
- 1.8″x1″ compact size
- Universal input 85~305VAC
- No load power consumption<0.1 W
- EMI Class B without additional components
- Wide operating temp. range -30~70°C
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- Isolation Class II
- Pass LPS
- 3 years warranty
Applications
- Industrial electrical equipment
- Mechanical equipment
- Factory automation equipment
- Hand-held electronic device
GTIN CODE MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
IRM-10 is a 10W miniature (45.725.421.5mm) AC-DC module-type power supply,
ready to be soldered onto the PCB boards of various kinds of electronic
instruments or industrial automation equipments. This product allows the
universal input voltage range of 85~305VAC. The 94V-0 flame retardant plastic
case and potted with silicone enhance the heat dissipation and meet the anti-
vibration demand up to 5G; moreover, it provides the fundamental resistance to
dust and moisture. With the high efficiency up to 82% and the extremely low
no-load power consumption below 0.1W, IRM-10 series fulfills the worldwide
regulation for the low power consumption requirement for electronics. The
entire series is a Class Il design (no FG pin), incorporating the built-in EMI
filtering components, enabling the compliance with BS EN/EN55032 Class B; the
supreme EMC features keep the end electronic units from electromagnetic
interference.
Model Encoding
SPECIFICATION
MODEL| IRM-10-3.3| IRM-10-5| IRM-10-12| IRM-10-15|
IRM-10-24
---|---|---|---|---|---
OUTPUT
| DC VOLTAGE| 3.3V| 5V| 12V| 15V| 24V
RATED CURRENT| 2.5A| 2A| 0.85A| 0.67A| 0.42A
CURRENT RANGE| 0 ~ 2.5A| 0 ~ 2A| 0 ~ 0.85A| 0 ~ 0.67A| 0 ~ 0.42A
RATED POWER| 8.25W| 10W| 10.2W| 10.05W| 10.08W
RIPPLE & NOISE (max.) **Note.2| 200mVp-p| 200mVp-p| 200mVp-p|
200mVp-p| 200mVp-p
VOLTAGE TOLERANCE Note.3| ±2.5%| ±2.5%| ±2.5%| ±2.5%| ±2.5%
LINE REGULATION| ±0.3%| ±0.3%| ±0.3%| ±0.3%| ±0.3%
LOAD REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME Note.4| 600ms, 30ms at full load
HOLD UP TIME (Typ.)**| 30ms/230VAC 8ms/115VAC at full load
INPUT
| VOLTAGE RANGE| 85 ~ 305VAC 120 ~ 430VDC
FREQUENCY RANGE| 47 ~ 440Hz
EFFICIENCY (Typ.)| 74%| 77%| 82%| 82%| 82%
AC CURRENT (Typ.)| 0.25A/115VAC 0.15A/230VAC
0.125A/277VAC
INRUSH CURRENT (Typ.)| COLD START 20A/115VAC 40A/230VAC
LEAKAGE CURRENT| < 0.25mA/277VAC
PROTECTION
| ****
OVERLOAD
| 115%~190% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
OVER VOLTAGE
| 3.8 ~ 4.95V| 5.75 ~ 6.75V| 13.8 ~ 16.2V| 17.25 ~ 20.25V| 27.6 ~ 32.4V
Protection type : Shut off o/p voltage, clamping by zener diode
ENVIRONMENT
| WORKING TEMP.| -30 ~ +70℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X,
Y, Z axes
SOLDERING TEMPERATURE| Wave soldering: 265℃,5s (max.); Manual soldering:
390℃,3s (max.)
OPERATING ALTITUDE Note.5| 2000 meters
SAFETY &
EMC
(Note.6)
| SAFETY STANDARDS| IEC62368-1, UL62368-1, TUV BS EN/EN62368-1, EAC TP
TC 004, BSMI CNS14336-1 approved
WITHSTAND VOLTAGE| I/P-O/P:3KVAC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032(CISPR32), CNS13438| Class B
Radiated| BS EN/EN55032(CISPR32), CNS13438| Class B
Harmonic Current (Note 5)| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| ——-
EMC IMMUNITY
| BS EN/EN55035, BS EN/EN61000-6-2
Parameter| Standard| Test Level /Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air; Level 2, 4KV contact, criteria A
Radiated Susceptibility| BS EN/EN61000-4-3| Level 3, criteria A
EFT/Burest| BS EN/EN61000-4-4| Level 3, criteria A
Surge| BS EN/EN61000-4-5| Level 3,1KV/L-N, criteria A
Conducted| BS EN/EN61000-4-6| Level 3, criteria A
Magnetic Field| BS EN/EN61000-4-8| Level 4, criteria A
Voltage Dips and interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30%
dip 25 periods,
>95% interruptions 250 periods
OTHERS
| MTBF| 9094.9K hrs min. Telcordia SR-332 (Bellcore) ; 1495.8K
hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 45.725.421.5 mm (LWH)
PACKING| 0.033Kg;270pcs/ 9.8Kg/0.94CUFT
NOTE|
- All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- Tolerance : includes set up tolerance, line regulation and load regulation.
- Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
- The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- The power supply is considered as an independent unit ,but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Block Diagram
Derating Curve
Output Derating VS Input Voltage
Mechanical Specification