MEAN WELL SLD-80 Series 80W Linear LED Driver User Manual
- June 1, 2024
- MEAN WELL
Table of Contents
MEAN WELL SLD-80 Series 80W Linear LED Driver
Specifications:
- Model: SLD-80-12, SLD-80-24
- Output:
- DC Voltage: 12V
- Constant Current Region: 8.4~12V (6.6A), 16.8~24V (3.3A)
- Rated Power: 79.2W
- Ripple & Noise: 150mVp-p
- Input:
- Voltage Range: 110~305VAC, 155~431VDC
- Frequency Range: 47~63Hz
- Power Factor: PF0.97/115VAC, PF0.95/230VAC, PF0.92/277VAC
- Efficiency: 90.5% (SLD-80-12), 91.5% (SLD-80-24)
Product Usage Instructions
Installation:
- Ensure the input voltage is within the specified range.
- Connect the LED driver to the power source following proper polarity.
- Make sure the total load does not exceed the maximum limit of the LED driver.
Operation:
- Turn on the power source to activate the LED driver.
- The LED driver will provide a constant voltage or constant current output based on the connected load.
Maintenance:
- Regularly check for any signs of damage or overheating.
- Keep the LED driver clean and free from dust accumulation.
Frequently Asked Questions (FAQ):
-
Q: Can I connect multiple LEDs to a single LED driver?
A: The maximum number of LEDs that can be connected depends on the total load and the circuit breaker capacity. Refer to the user manual for detailed guidelines. -
Q: What should I do if the LED driver is producing flickering light?
A: Check the input voltage stability and ensure proper connections. Flickering may occur due to fluctuating power sources. -
Q: How can I determine if the LED driver is compatible with my LED lights?
A: Match the voltage and current requirements of your LED lights with the specifications of the LED driver. Ensure compatibility for efficient and safe operation.
Features
- Constant Voltage + Constant Current mode output
- Wide input range 110-305VAC with PFC function
- Compliance with BS EN/EN61347 regulation
- Class 2/ II power unit (Except for 12V)
- Slim and Linear housing Design
- No load power consumption <0.5W
- 3 years warranty
Applications
- Panel lighting
- Strip lighting
- Decoration lighting
- Troffer lighting
- Signage and display
- Cove lighting
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
SLD-80 series is an 80W AC/DC LED driver featuring the dual modes constant voltage and constant current output. SLD-80 operates from 110~305VAC and offers models with different rated voltage ranging between 12V and 56V. Thanks to the high efficiency up to 92%, with the fanless design, the entire series can operate for -20°C ~ +90°C case temperature under free air convection. SLD-80 design with low profile and linear housing which is good for signage and linear luminaire applications.
Model Encoding
SPECIFICATION
MODEL | SLD-80-12 | SLD-80-24 |
---|
OUTPUT
| DC VOLTAGE| 12V| 24V
CONSTANT CURRENT REGION Note.2| 8.4~12V| 16.8 ~24V
RATED CURRENT| 6.6A| 3.3A
RATED POWER Note.5| 79.2W| 79.2W
RIPPLE & NOISE (max.) **Note.3| 150mVp-p| 240mVp-p
VOLTAGE TOLERANCE Note.4| ±4.0%| ±3.0%
LINE REGULATION| ±0.5%| ±0.5%
LOAD REGULATION| ±1.5%| ±0.5%
SETUP, RISE TIME Note.6| 500ms, 80ms 115VAC / 230VAC
HOLD UP TIME (Typ.)**| 10ms/230VAC 10ms/115VAC
INPUT
| VOLTAGE RANGE Note.5| 110~ 305VAC 155~ 431VDC
(Please refer to “STATIC CHARACTERISTIC” section)
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR| PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load
(Please refer to “POWER FACTOR (PF) CHARACTERISTIC” section)
TOTAL HARMONIC DISTORTION| THD< 10%(@load≧60%/115VC,230VAC; @load≧75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
EFFICIENCY (Typ.)| 90.5%| 91.5%
AC CURRENT| 0.9A / 115VAC 0.45A / 230VAC
0.38A/277VAC
INRUSH CURRENT(Typ.)| COLD START 50A(twidth=270 μ s measured at 50%
Ipeak) at 230VAC ; Per NEMA 410
MAX. No. of PSUs on 16A CIRCUIT BREAKER| 8 units (circuit breaker of
type B) / 16 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.25mA / 277VAC
NO LOAD POWER CONSUMPTION| <0.5W
PROTECTION
| OVER CURRENT| 95 ~ 108%
Constant current limiting or Hiccup mode, recovers automatically after fault
condition is removed
SHORT CIRCUIT| Hiccup mode, recovers automatically after fault condition
is removed
OVER VOLTAGE| 14 ~ 17V| 28 ~ 34V
Shut down output voltage, re-power on to recovery
OVER TEMPERATURE| Shut down output voltage, re-power on to recovery
ENVIRONMENT
| WORKING TEMP.| Tcase=-20 ~ +90℃ (Please refer to “ OUTPUT LOAD vs
TEMPERATURE” section)
MAX. CASE TEMP.| Tcase=+90℃
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP.| -40 ~ +80℃
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X,
Y, Z axes
SAFETY & EMC
| SAFETY STANDARDS Note.8| UL8750,CSA C22.2 No. 250.13-12, ENEC BS
EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384, EAC TP TC 004,
GB19510.1,GB19510.14, IS15885(Part2/Sec13) ,EN60335-1 approved
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION **Note.8| Parameter| Standard| Test
Level/Note**
Conducted| BS EN/EN55015(CISPR15) ,GB/T 17743,
EN IEC 55014-1(CISPR 14-1)
| —–
Radiated| BS EN/EN55015(CISPR15) ,GB/T 17743,
EN IEC 55014-1(CISPR 14-1)
| —–
Harmonic Current| BS EN/EN61000-3-2 ,GB17625.1| Class C @load≥60%
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY| BS EN/EN61547 ,EN IEC 55014-2
Parameter| Standard| Test Level/Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 2
EFT/Burst| BS EN/EN61000-4-4| Level 2
Surge| BS EN/EN61000-4-5| 1KV/Line-Line
Conducted| BS EN/EN61000-4-6| Level 2
Magnetic Field| BS EN/EN61000-4-8| Level 2
Voltage Dips and Interruptions| BS EN/EN61000-4-11| 70% residual volatge for
10 periods , 0% residual volatge for 0.5 periods , 40% residual volatge for 10
periods , 70% residual volatge for 25 periods
OTHERS
| MTBF| 2666.8K hrs min. Telcordia SR-332 (Bellcore) ;
260.9K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 3203016.8mm (LWH)
PACKING| 0.206 Kg; 64pcs / 14.184Kg / 0.75CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC
input, rated current and 25℃ of ambient temperature.
2. Please refer to “DRIVING METHODS OF LED MODULE”.
3. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
4. Tolerance : includes set up tolerance, line regulation and load regulation.
5. De-rating may be needed under low input voltages. Please refer to the “STATIC CHARACTERISTIC” sections for details.
6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to an increase of the set up time.
7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
8. This series meets the typical life expectancy of 30000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃ or less.
9. Please refer to the warranty statement on MEAN WELL’s website at http://www.meanwell.com
10. RCM is on a voluntary basis. Non IC classification Independent LED control gear is not suitable for residential installations but recommend to be used for commercial decoration/sign board/Luminaire lighting purpose.
w.c11o. mTh.e ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
d from| Arro| duct Liability Disclaimer:For detailed
information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
File Name:SLD-80-SPEC 2024-03-12
MODEL| SLD-80-56
---|---
OUTPUT
| RATED CURRENT| 1400mA
RATED POWER Note.2| 78.4W
CONSTANT CURRENT REGION Note.3| 30 ~56V
FULL POWER CURRENT RANGE| 1400~2100mA
OPEN CIRCUIT VOLTAGE (max.)| 60V
CURRENT ADJ. RANGE| 700~2100mA
CURRENT RIPPLE| 5.0%(@rated current)
CURRENT TOLERANCE| ±5%
SET UP TIME Note.5| 500ms/230VAC, 1200ms/115VAC
INPUT
| VOLTAGE RANGE Note.2| 110 ~ 305VAC 155VDC ~ 431VDC
(Please refer to “STATIC CHARACTERISTIC” and “ DRIVING METHODS OF LED MODULE”section)
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR (Typ.)| PF≧0.97 / 115VAC, PF≧0.95 / 230VAC, PF≧0.92 /
277VAC at full load
(Please refer to “Power Factor Characteristic” section)
TOTAL HARMONIC DISTORTION| THD< 10% (@ load≧60% at 115VAC/230VAC ,@load≧75% at 277VAC)
Please refer to “TOTAL HARMONIC DISTORTION (THD)” section
EFFICIENCY (Typ.)| 92.0%
AC CURRENT (Typ.)| 0.9A / 115VAC 0.45A / 230VAC
0.38A / 277VAC
INRUSH CURRENT(Typ.)| COLD START 50A(twidth=270 μ s measured at 50%
Ipeak) at 230VAC; Per NEMA 410
MAX. NO. of PSUs on 16A CIRCUIT BREAKER| 8 unit(circuit breaker of type
B) / 16 units(circuit breaker of type C) at 230VAC
LEAKAGE CURRENT| <0.25mA / 277VAC
NO LOAD POWER CONSUMPTION| <0.5W
PROTECTION
| OVER POWER| 110 ~ 150%
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT| Hiccup mode, recovers automatically after fault condition
is removed
OVER VOLTAGE| 60 ~ 70V
Shut down output voltage, re-power on to recovery
OVER TEMPERATURE| Shut down output voltage, re-power on to recovery
ENVIRONMENT
| WORKING TEMP.| Tcase=-20 ~ +90℃(Please refer to “OUTPUT LOAD vs
TEMPERATURE” section)
MAX. CASE TEMP.| Tcase=+90℃
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP.| -40 ~ +80℃
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 60℃)
VIBRATION| 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X,
Y, Z axes
SAFETY & EMC
| SAFETY STANDARDS Note.4| UL8750,CSA C22.2 No. 250.13-12, ENEC BS
EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384, EAC TP TC 004,
GB19510.1,GB19510.14, IS15885(Part2/Sec13) ,EN60335-1 approved
WITHSTAND VOLTAGE| I/P-O/P:3.75KVAC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Note.4| Parameter| Standard| Test
Level/Note
Conducted| BS EN/EN55015(CISPR15) ,GB/T 17743,
EN IEC 55014-1(CISPR 14-1)
| —–
Radiated| BS EN/EN55015(CISPR15) ,GB/T 17743,
EN IEC 55014-1(CISPR 14-1)
| —–
Harmonic Current| BS EN/EN61000-3-2 ,GB17625.1| Class C @load≥60%
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY| BS EN/EN61547 ,EN IEC 55014-2
Parameter| Standard| Test Level/Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air ; Level 2, 4KV contact
Radiated| BS EN/EN61000-4-3| Level 2
EFT/Burst| BS EN/EN61000-4-4| Level 2
Surge| BS EN/EN61000-4-5| 1KV/Line-Line
Conducted| BS EN/EN61000-4-6| Level 2
Magnetic Field| BS EN/EN61000-4-8| Level 2
Voltage Dips and Interruptions| BS EN/EN61000-4-11| 70% residual volatge for
10 periods , 0% residual volatge for 0.5 periods , 40% residual volatge for 10
periods , 70% residual volatge for 25 periods
OTHERS
| MTBF| 2666.8K hrs min. Telcordia SR-332 (Bellcore) ;
260.9K hrs min. MIL-HDBK-217F (25℃)
DIMENSION| 3203016.8mm (LWH)
PACKING| 0.206 Kg; 64pcs / 14.184Kg / 0.75CUFT
NOTE| 1. All parameters NOT specially mentioned are measured at 230VAC
input, rated current and 25℃ of ambient temperature.
2. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
3. Please refer to “DRIVING METHODS OF LED MODULE”.
4. This series meets the typical life expectancy of 30000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃ or less.
5. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
6. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
7. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
8. Please refer to the warranty statement on MEAN WELL’s website at http://www.meanwell.com
9. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
10. RCM is on a voluntary basis. Non IC classification Independent LED control gear is not suitable for residential installations but recommend to be used
for commercial decoration/sign board/Luminaire lighting purpose.
| Arrow.com.| duct Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx File Name:SLD-80-SPEC 2024-03-12
BLOCK DIAGRAM
DRIVING METHODS OF LED MODULE
SLD-80-12,24
This series is able to work in either Constant Current mode (a direct
driveway) or Constant Voltage mode (usually through an additional DC/DC
driver) to drive the LEDs.
In the constant current region, the highest voltage at the output of the
driver depends on the configuration of the end systems. Should there be any
compatibility issues, please contact MEAN WELL
Typical output current normalized by rated current (%)
SLD-80-56
OUTPUT LOAD vs TEMPERATURE
STATIC CHARACTERISTIC
POWER FACTOR (PF) CHARACTERISTIC
TOTAL HARMONIC DISTORTION (THD)
EFFICIENCY vs LOAD
SLD-80 series possess superior working efficiency that up to 91.5% can be reached in field applications.
- 24V Model, Tcase at 75℃
- 24V Model, Tcase at 75℃
LIFETIME
Mechanical Specification
INSTALLATION MANUAL
Please refer to: http://www.meanwell.com/manual.html
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>