HALO SMD LED 4 Inch Round Square Field Selectable Instructions

June 1, 2024
HALO

HALO SMD LED 4 Inch Round Square Field Selectable Instructions

HALO SMD LED 4 Inch Round Square Field Selectable
Instructions

SMD4xWH and SMD6xWH Selectable CCT Instructions

Packaging Contents

HALO SMD LED 4 Inch Round Square Field Selectable - Packaging
Contents

Note : SMD4 includes Friction Clips (J). SMD6 includes Torsion Springs (G). Not included with SMD4-CA or SMD6-CA. Recessed Housing Kit is needed for housing installations.

Note : Items G, H, I and J are part of the Recessed Housing Kit. The Recessed Housing Kit Sold Separately

G. (2) Torsion Springs

H. E26 Edison screw base adapte

I. (2) #8-32 Friction Blade Screws

J. (2) Friction Clips

Selector Switch (2700K, 3000K, 3500K, 4000K, 5000K)
Choose your favorite correlated color temperature (CCT) from 5 options using the switch.

ITEMS REQUIRED

(Purchase separately)
• #2 Philips Screwdriver
• Gloves

IMPORTANT SAFETY INSTRUCTIONS
When using product, basic precautions should always be followed, including the following:

  • Read and follow these instructions.
  • Heed all warnings, including below warnings AND those included on product.
  • HALO® luminaires (fixtures) are designed to meet the latest NEC requirements and are certified in full compliance with UL. Before attempting installation of any lighting luminaire check your local electrical code. This code sets the wiring standards for your locality and should be carefully studied before starting.

SAVE THESE INSTRUCTIONS AND WARNINGS.

Risk of Fire – MINIMUM 90°C SUPPLY CONDUCTORS.
If uncertain, consult an electrician.

Risk of Electric Shoc k – To avoid possible electrical shock, be sure that power supply is turned off at fuse box or circuit breaker before installing or servicing luminaire.

Risk of Fire/Electric Shock- LED Retrofit Kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. Luminaire wiring and electrical parts may be damaged when drilling for installation of LED retrofit kit. Check for enclosed wiring and components.

  • To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
    Edges may be Sharp –
    Wear gloves while handling.

  • Connect fixture to a 120V, 60 Hz power source. Any other connection voids the warranty.

  • Fixture should be installed by persons with experience in household wiring or by a qualified electrician. The electrical system, and the method of electrically connecting the fixture to it, must be in accordance with the National Electrical Code and local building codes.

  • Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

  • Please examine all parts that are not intended to be replaced by the retrofit kit for damage and replace any damaged parts prior to installation of the retrofit kit.

  • This device is not intended for use with emergency exits.

  • For Canada only per CSA C22.2 No. 250.1-16, retrofits for luminaire conversion: The retrofit kit is accepted as a component of a luminaire where the suitability of the combination shall be determined by authorities having jurisdiction. Product must be installed by  a qualified electrician in accordance with the applicable and appropriate electrical codes. The installation guide does not supersede local or national regulations for electrical installations.

DIMMING
Halo SMD is designed for dimming with many 120V Leading Edge (LE) and Trailing Edge (TE) phase control dimmers. Dimming capability may be enhanced with select dimmers that feature low end trim adjustment. (Consult dimmer manufacturer for specific load compatibility and application information. Note some dimmers require a neutral in the wallbox.) For the latest Halo SMD product information, please refer to specifications online at www.cooperlighting.com

DETERMINING WHICH INSTALLATION METHOD TO USE
For use with any 5 or 6 inch diameter recessed luminaire constructed of steel or aluminum with an internal volume that exceeds 107.9 in³ in addition to those noted below:
For use with any 4 inch diameter recessed luminaire constructed of steel or aluminum with an internal volume that exceeds 62.3 in³ in addition to those noted below:
NOTE : Recessed Housing Installation Kit sold separately.

Risk of Electric Shock – To avoid possible electrical shock, be sure that power supply is turned off at fuse box or circuit breaker before installing or servicing luminaire.

ELECTRICAL JUNCTION BOXES

Mounting to recessed mounted standard junction boxes
NOTE : The LED fixture installs onto many standard recessed ceiling and wall mounted junction boxes (Fig. 1)**.

  • 4” octagon
  • 4” square
  • 4” round
  • 3-1/2” round new work
  • 3-1/2” round old work

SMD4xWH and SMD6xWH Selectable CCT Instructions

IL51886622

(Box types and site condition vary. Installer to ensure compatibility at fit, wiring and proper mounting.) The junction box must be a minimum 1-1/2 inch in depth for proper installation. Recommended boxes shown in (Fig 1).
NOTE** : The SMD6 1200LM Series has a taller driver. The 4inch x 2-1/8 deep Square junction box is recommended for installation. The depth of the junction box must be a MINIMUM 2-1/8inch deep. The 4inch x 2-1/8 deep Octagon junction box can be used with limited number of wires or smaller gauge wires and wire caps.

Fig. 1

HALO SMD LED 4 Inch Round Square Field Selectable - Figure
1

RECESSED DOWNLIGHT HOUSINGS

WARNING : Risk of Fire or Electric Shock. For Use only with the following recessed housings.

  • The SMD Recessed Housing Kit comes with a dedicated LED connector for California Title 24 Compliance and is UL Listed for installation into Halo recessed LED housings (see housing list).
  • The SMD Recessed Housing Kit also includes an E26 Edison screw base adapter to retrofit standard screw base recessed housings. The SMD is UL Listed and Classified for retrofit in the following housings:

The SMD is UL Listed or Classified for use with any 4, 5 or 6 inch diameter recessed housing constructed of steel or aluminum with an internal volume that exceeds 107.9 cubic inches in addition to those noted below.

5 or 6 inch
SMD6x Can be used in 5 or 6 inch housings below:
HALO ®: H7ICAT, H7RICAT, H7ICT, H7RICT, H7ICATNB, H7ICTNB, H7T, H7RT, H7TNB, H7TCP, H7UICT, H7UICAT, H27ICAT, H27RICAT, H27ICT, H27RICT, H27T, H27RT, E7ICAT, E7RICAT, E7ICATNB, E27ICAT, E27RICAT, E7TAT, E7RTAT, H5ICAT, H5ICATNB, H5RICAT, H5T, H5TNB, H5RT, H5TM, H25ICAT, H25ICATNB, E5ICAT, E5ICATNB, E5RICAT, E5TAT, E5TATNB, E5RTAT
HALO® LE D: H750ICAT(D010), H750RICAT(D010), H750T, H750TCP, H2750ICAT, H2750RICAT, H550ICAT(D010), H550RICAT(D010), H750FR2ICAT(D010), H550FR2ICAT(D010), E750ICAT, E750RICAT, E550ICAT, E550RICAT

HALO® LED Retrofit: ML7BXRFK, ML7E26RFK 4 inch SMD4x Can be used in 4 inch recessed housings below:
HALO® LED : H995ICAT, H995RICAT, H245RICAT, H245ICAT, H45ICATD010, H45RICATD010, H450FR2ICAT(D010)
HALO® : H99ICAT, H99RTAT, H99TAT, E4ICATSB, E4TATSB, E4RTATSB
5 or 6 inch
Juno : IC22, IC22R, IC22W, IC22S, IC23, IC23W, IC21, IC21R, IC2, TC2, TC2R, IC20, IC20R, IC25, IC25R, IC25W, IC25S, TC20, TC20R
Lightolier : 1104ICS, 1104ICR, 1104SIC, 1104SICR, 1004ICS, 1004ICR, 1004SIC, 1004SICR 1104ICX – Requires installation of Halo ML7RAB retrofit adapter band accessory
Capri : CR1, PR1, QL1, R9ASIC, R5*

Progress : P87-AT, P86TG
Lithonia : L7X, L7XP
Thomas : PS1, R9ASIC/PS9RM
Prescolite : IBXS
Commercial Electric: C7ICA (H3), H18
Elco : (HL7ICA) EL7ICA
4 inch
Utilitech : CR04ICAT
Thomas : PS4
Lithonia : L3, L3R
Commercial Electric : HBR2000BA
, HBR2000R
Juno : TCI
, TCIR
Progress Lighting : P830-TG
, P832-TG

  • Requires installation of friction clips (included).

WIRING INTO EXISTING JUNCTION BOXES

  • Using wire connectors connect Black wire to hot supply wire, connect White wire to Neutral wire and also Connect the ground wire (attached to the bracket) to the ground wire in the junction box (Fig 1 & Fig 2).
  • Bundle any excess length of wire inside the junction box in preparation for insertion.
  • Install the fixture. (See MOUNTING section for specific instructions).

WIRING INTO DOWNLIGHT HOUSINGS

WARNING : Risk of Fire or Electric Shock. For Use only
with the listed recessed housings.
NOTE: Recessed Housing Installation Kit sold separately.
For a recessed can installation, wrap the bare (copper) ground wire from the mounting plate (see Fig. 3) around one of the three following connection methods.

  • Using existing screw inside the housing (Fig. 4).
  • Using supplied #8-32 Hex Nut (D) onto existing stud inside the housing (Fig. 5).
  • Using supplied #8-32 Sheet Metal Screw (F) into existing hole inside. (Fig. 6).

NOTE : If no hole exists, drill a small pilot hole and use the provided

8-32 Sheet Metal Screw (F) as the ground screw.

Fig. 2

Fig. 3 (6in Mounting Plate)

Fig. 4

Fig. 5

Fig. 6

Wiring into E26 Edison screw base recessed housing (retrofit)

NOTE: Recessed Housing Installation Kit sold separately.

  1. Remove mounting bracket and plate from inside existing recessed housing (if installed).
  2. Remove socket from plate (if installed).
  3. Screw Edison base Adapter (H) into existing Edison base socket in housing. (Fig. 7)
  4. Using wire connectors connect Black wire to hot supply wire, connect White wire to Neutral wire and also Connect the ground wire (attached to the bracket) to the ground wire in the junction box (Fig. 2).
  5. Bundle any excess length of wire inside the housing (above the fixture) in preparation for insertion.
  6. Install the fixture. (See MOUNTING section for specific instructions).

Wiring into HALO H2750x, H550x, H750, and H245, H995x Series LED (non-screw base) Housings

  1. Using wire connectors connect Black wire to hot supply wire, connect White wire to Neutral wire and also Connect the ground wire (attached to the bracket) to the ground wire in the junction box (Fig. 2).
  2. Bundle any excess length of wire inside the housing (above the module) in preparation for insertion.
  3. Install the fixture. (See MOUNTING section for specific instructions).

MOUNTING
Existing Junction Box Installation

  1. Secure the included mounting plate to the Junction Box as shown in (Fig. 8) using (2) #8-32 Junction Box Screws (C) through the appropriate slots (depending on the manufacturer/size of j-box being used). If installing multiple square fixtures and alignment is critical, take note of the orientation of the triangular notches so it can be matched in subsequent installations.
  2. Properly wire the unit as instructed in the WIRING section of these instructions.
  3. Align the driver/wiring so that it will pass through the opening in the mounting plate (Fig. 9).
  4. Take care not to trap/pinch any wires. Locate both spring members into the mounting plate pocket receptacles.
    Press with the heel of your hand on the lens directly in the center of the lens. (UNLESS IT IS A 1200LM SMD SERIES).***

*** For the 1200LM SMD Series, the driver is larger.
In order to install align the springs with the pocket receptacles as shown in Fig 9. When the springs are in the pocket receptacles push in one side of the spring first and then push the other side of the spring after the first side has been pushed through the mounting plate. For square fixtures, this will be pushing in one corner first and then the other. (Fig 10.)

NOTE : It is acceptable to press directly on the lens as there are no components which will be damaged in this process.

NOTE: For 1200LM Series, do NOT install by pushing in the center. This will damage the spring. Install by pushing one side of the spring in first and then the other.

Fig. 7

Fig. 8

Fig. 9

Fig. 10 (1200LM SERIES)

Downlight Housing Installation
Determine which installation method is required based on the housing being installed within – friction blade or torsion spring.
NOTE : Be sure to wear appropriate protective gloves to avoid possible cuts/scrapes during installation.

NOTE: Recessed Housing Installation Kit sold separately
Friction Blades
NOTE: Friction Blades included in Recessed Housing Installation Kit sold separately.

  1. Install the friction Blades (2X) (J) to the rear of the mounting plate into the positions shown in (Fig. 11) by screwing them into the proper location using the provided M3 x 4mm Screws (I).
  2. Align the driver/wiring so that it will pass through the opening of the mounting plate (Fig 9). Snap the mounting plate onto the fixture.
  3. Flex the friction blades to allow them to fit inside the opening of the housing. Once started into the housing, simply press the blades into the housing until the top of the mounting plate rests against the ceiling.

Fig. 11a (5″ & 6″)

Fig. 11b (4″)

Torsion Springs (5” & 6” Downlight housings only)

NOTE: Torsion Springs included in Recessed Housing Installation Kit sold separately.

  1. Install the Torsion Springs bracket Assembly (G) onto the rear of the mounting plate by orienting the tongue of the bracket to pass through the appropriate slot (see Figure 12). Next, twist the bracket assembly 90°. The bracket should now be locked into the slot without rotating but should be free to slide along the slots (Fig. 13). This will allow the mounting plate to be adjusted independently of the housing for properly aligning the square LED fixtures.
  2. Repeat this procedure using the 2nd torsion spring/ bracket subassembly 180° apart from the first assembly. Each bracket assembly should be 180° apart.
  3. Align the driver/wiring so that it will pass through the opening of the mounting plate (Fig 9). Snap the trim plate onto the fixture.
  4. Now that the mounting plate is secure to the LED fixture, pinch the ends of the torsion springs together (both sides) and place them into the torsion spring receivers inside the recessed housing (supplied by others). See Figure 14.
  5. With the torsion springs located inside the housing torsion spring receivers, press the mounting plate up into the housing until it stops against the ceiling.

Fig. 12

Fig. 13

Fig. 14

REMOVAL

Junction Box

  1. Simply pull down firmly on LED fixture until spring clips disengage from the mounting plate.
  2. Disconnect wiring.
  3. Unscrew the mounting plate from the junction box.

Downlight Housing

  1. Simply pull down firmly on LED fixture until spring clips disengage from the mounting plate.
  2. Disconnect wiring.
  3. Pull down firmly on the mounting plate until the torsion springs can be accessed. If using friction blades, pull SMD mounting plate out of the housing slowly.
  4. Squeeze the torsion springs together (each side) and remove from the housing.

5-YEAR LIMITED WARRANTY

THE FOLLOWING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, WHETHER
EXPRESS, IMPLIED OR STATUTORY INCLUDING, BUT NOT LIMITED TO, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.

Cooper Lighting Solutions warrants to customers that, for a period of five years from the date of purchase, Cooper Lighting Solutions products will be free from defects in materials and workmanship.
The obligation of Cooper Lighting Solutions under this warranty is expressly limited to the provision of replacement products. This warranty is extended only to the original purchaser of the product. A purchaser’s receipt or other proof of date of original purchase acceptable to Cooper Lighting Solutions.

This is required before warranty performance shall be rendered.
This warranty does not apply to Cooper Lighting Solutions products that have been altered or repaired or that have been subjected to neglect, abuse, misuse or accident (including shipping damages). This warranty does not apply to products not manufactured by Cooper Lighting Solutions which have been supplied, installed, and/or used in conjunction with Cooper Lighting Solutions products.
Damage to the product caused by replacement bulbs or corrosion or discoloration of brass components are not covered by this warranty.

LIMITATION OF LIABILITY:

IN NO EVENT SHALL COOPER LIGHTING SOLUTIONS BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES (REGARDLESS OF THE FORM OF ACTION, WHETHER IN CONTRACT, STRICT LIABILITY, OR IN TORT INCLUDING NEGLIGENCE), NOR FOR LOST PROFITS; NOR SHALL THE LIABILITY OF COOPER LIGHTING SOLUTIONS FOR ANY CLAIMS OR DAMAGE ARISING OUT OF OR CONNECTED WITH THESE TERMS OR THE MANUFACTURE, SALE, DELIVERY, USE, MAINTENANCE, REPAIR OR MODIFICATION OF COOPER LIGHTING SOLUTIONS PRODUCTS, OR SUPPLY OF ANY REPLACEMENT PARTS THEREFORE, EXCEED THE PURCHASE PRICE OF Cooper Lighting Solutions PRODUCTS GIVING RISE TO A CLAIM. NO LABOR CHARGES WILL BE ACCEPTED TO REMOVE OR INSTALL FIXTURES.
All returned products must be accompanied by a Return Goods Authorization Number issued by the Company and must be returned freight prepaid. Any product received without a Return Goods Authorization Number from the Company will be refused.
Cooper Lighting Solutions is not responsible for merchandise damaged in transit. Repaired or replaced products shall be subject to the terms of this warranty and are inspected when packed. Evident or concealed damage that is made in transit should be reported at once to the carrier making the delivery and a claim filed with them.
Reproductions of this document without prior written approval of Cooper Lighting Solutions are strictly prohibited.

FCC Statement

Note : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off an on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

  • This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

This device complies with ISED ICES Standard Canada ICES-005(B) / NMB-005 (B).

Cooper Lighting Solutions
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com

Canada Sales
5925 McLaughlin Road
Mississauga, Ontario L5R 1B8
P: 905-501-3000
F: 905-501-3172

© 2022 Cooper Lighting Solutions
All Rights Reserved
Printed in China
Publication No. IB518371ML

Cooper Lighting Solutions is a registered trademark.
All trademarks are property of their respective owners.

Product availability, specifications, and compliances are subject to change without notice

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

HALO User Manuals

Related Manuals