MEAN WELL LOP-200 Series 200W 4 Inch ×2 Inch Low Profile Open Frame Power Supply Owner’s Manual

June 15, 2024
MEAN WELL

MEAN WELL LOP-200 Series 200W 4 Inch ×2 Inch Low Profile Open Frame Power

Supply

MEAN WELL LOP-200 Series 200W 4 Inch ×2 Inch Low Profile Open Frame Power
Supply

Features

  • MEAN WELL Patent Number: ZL 202223277512.1
  • 4″×2″ compact size with low profile (25.4mm)
  • 80~264Vac input with PFC, No load power consumption<0.5W
  • Global certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1/-2-16)
  • 150%peak load @ 3s
  • 140W convection, 200W with FAN 10.98CM forced-cooled
  • Suitable for Class I or Class Il installations
  • Over voltage category I (OVC Ш)
  • -40 ~ +80°C wide range operation temperature
  • High efficiency up to 94%
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Extremely low leakage current
  • Operating altitude up to 5000 meters
  • Built-in 12V/0.5A for external FAN
  • 3 years warranty

Applications

  • Industrial automation machinery
  • Industrial control system
  • Mechanical and electrical equipment
  • Electronic instruments, equipments or apparatus
  • Power sourcing equipment of PoE
  • Medical devices

GTIN CODE MW Search : https://w.meanwell.com/serviceGTIN.aspx

Description

LOP-200 is a 200W highly reliable green PCB type low profile power supply with a high power density (25W/in’) on the 4″ by 2″ footprint. It accepts 80~264VAC input and offers various output voltages between 12V and 54V. The working efficiency is up to 94% and the extremely low no load powerconsumption is down below 0.5W.

LOP-200 is able to be used for both Class I (with FG) and Class I(no FG) system design. LOP-200 is equipped with complete protection functions; It is complied with the international safety regulations such as IEC/BS EN/EN/UL62368-1,IEC/BS EN/EN60335-1,IEC/BS EN/EN61558-1/-2-16, IEC/BS EN/EN60601-1.LOP-200 serves as a high price-to-performance power supply solution for various industrial applications. The extremely low leakage current is less than 500 MA.In addition, it conforms to the international medical regulations (2*MOPP) and EMC BS EN/EN55011, perfectly fitting all kinds of BF rated “patient contact” medical system equipment.

Model Encoding

MEAN WELL LOP-200 Series 200W 4 Inch ×2 Inch Low Profile Open Frame Power
Supply 1

SPECIFICATION

MODEL| LOP-200- 12| LOP-200- 15| LOP-200- 18| LOP-200- 24| LOP-200- 27| LOP-200- 36| LOP-200- 48| LOP-200- 54
---|---|---|---|---|---|---|---|---











OUTPUT

| DC VOLTAGE| 12V| 15V| 18V| 24V| 27V| 36V| 48V| 54V


CURRENT

| Peak(3sec.)| 25A| 20A| 16.7A| 12.5A| 11.1A| 8.3A| 6.3A| 5.6A
10.98CF M| 16.7A| 13.4A| 11.1A| 8.4A| 7.5A| 5.6A| 4.2A| 3.8A
Convection| 11.7A| 9.4A| 7.8A| 5.9A| 5.3A| 3.9A| 3.0A| 2.7A


RATED POWER

| Peak(3sec.)| 300W| 300W| 300.6W| 300W| 299.7W| 298.8W| 302.4W| 302.4W
10.98CF M| 200.4W| 201W| 199.8W| 201.6W| 202.5W| 201.6W| 201.6W| 205.2W
Convection| 140.4W| 141W| 140.4W| 141.6W| 143.1W| 140.4W| 144W| 145.8W
RIPPLE & NOISE (max.)

Note.2

| 120mVp-p| 150mVp-p| 180mVp-p| 200mVp-p| 200mVp-p| 250mVp-p| 250mVp-p| 250mVp-p
VOLTAGE ADJ. RANGE

(MAIN OUTPUT)

| 11.4~12.6V| 14.3~15.8V| 17.1~18.9V| 22.8~25.2V| 25.6 ~ 29V| 34.2 ~37.8V| 45.6 ~50.4V| 52 ~58V
VOLTAGE TOLERANCE

Note.3

| ±3.0%| ±3.0%| ±3.0%| ±2.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%| ±1.0%
SETUP, RISE TIME| 1000ms, 30ms/230VAC            1500ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)| 16ms@140W load , 8ms@200W load





INPUT

| VOLTAGE RANGE Note.4| 80 ~ 264VAC            113 ~ 370VDC
FREQUENCY RANGE| 47 ~ 63Hz
POWER FACTOR| PF>0.95/230VAC PF>0.98/115VAC at full load
EFFICIENCY (Typ.)| 93%| 93%| 93.5%| 94%| 94%| 94%| 94%| 94%
AC CURRENT (Typ.)| 2.5A/115VAC            1A/230VAC
INRUSH CURRENT (Typ.)| COLD START 40A/115VAC            80A/230VAC
LEAKAGE CURRENT| Earth leakage current < 500μA(rms) @ 264VAC , touch current < 70μA(rms) @ 264VAC




PROTECTION

| ****

OVERLOAD

| 105 ~ 150% rated output power, Protection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed


OVER VOLTAGE

| 13.2 ~ 15.6V| 16.5 ~ 19.5V| 19.8 ~ 23.4V| 26.4 ~ 31.2V| 29.7 ~ 35.1V| 39.6 ~ 46.8V| 52.8 ~ 62.4V| 59.4 ~ 67.5V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Protection type : Shut down o/p voltage, recovers automatically after temperature goes down or re-power on to recover
FUNCTION| EXTERNAL FAN SUPPLY| 12V@0.5A for driving a fan / 12V@0.1A without fan ; (10.98CFM) tolerance -20% ~ +15% at main output 20% rated current




ENVIRONMENT

| WORKING TEMP.| -40 ~ +80℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes



















SAFETY & EMC

(Note 5)

| ****

SAFETY STANDARDS

| CB  IEC62368-1, IEC60335-1, IEC61558-1/-2-16, IEC60601-1;

TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16, BS EN/EN60601-1(3.2 Version); UL UL62368-1, ANSI / AAMI ES60601-1(3.2 Version) ;

CCC GB4943.1 ; RCM AS/NZS 61558-1/-2-16; EAC TPTC 004 approved.

---|---|---
ISOLATION RESISTANCE| Primary-Secondary:  2xMOPP,  Primary-Earth:1xMOPP, Secondary-Earth:1xMOPP


OVER VOLTAGE CATEGORY

| IEC/EN 61558-1/-2-16(OVC Ⅲ, altitude up to 2000M ) IEC/EN/UL 62368-1 (OVC Ⅱ, altitude up to 5000M ) IEC/EN 60335-1 (OVC Ⅱ, altitude up to 5000M ) IEC/EN 60601-1   (OVC Ⅱ, altitude up to 4000M )
PROTECTIVE EXTRA-LOW VOLTAGE| IEC/EN61558-2-16 (SELV ) IEC/EN/UL 62368-1 (SELV / ES1 )
WITHSTAND VOLTAGE| I/P-O/P:4KVAC  I/P-FG:2KVAC  O/P-FG:1.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH




EMC EMISSION

| Parameter| Standard| Test Level / Note


Conducted & Radiated

| BS EN/EN55032(CISPR32) BS EN/EN55011(CISPR11)| ClassⅠ: Class B , Class Ⅱ: Class A
BS EN/EN55014(CISPR32)| ClassⅠ: Class B
Harmonic Current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| ——-







EMC IMMUNITY

| BS EN/EN55035,BS EN/ EN61000-6-2
Parameter| Standard| Test Level /Note
ESD| BS EN/EN61000-4-2| Level 4, 15KV air ; Level 4, 8KV contact
RF field susceptibility| BS EN/EN61000-4-3|
EFT bursts| BS EN/EN61000-4-4| Level 3, 2KV
Surge susceptibility| BS EN/EN61000-4-5|
Conducted susceptibility| BS EN/EN61000-4-6| Level 3, 10V
Magnetic field immunity| BS EN/EN61000-4-8|
Voltage Dips and interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 100% dip 1 periods, 30% dip 25 periods,

>95% interruptions 250 periods


OTHERS

| MTBF| 2928.9K hrs min.      Telcordia SR-332 (Bellcore) ;       393.9K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION| 101.650.8 25.4mm (LWH)
PACKING| 0.21Kg; 36pcs/10Kg/0.95CUFT
NOTE|

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0. 1ut & 47ut parallel capacitor.
  3. Tolerance: includes set up tolerance, line regulation and load regulation.
  4. Derating may be needed under low input voltages. Please check the derating curve for more details.
  5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)

Product Liability Disclaimer : For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Block Diagram

MEAN WELL LOP-200 Series 200W 4 Inch ×2 Inch Low Profile Open Frame Power
Supply 2

Derating Curve

MEAN WELL LOP-200 Series 200W 4 Inch ×2 Inch Low Profile Open Frame Power
Supply 3

Cooling Max. Output Power
Free air convection 140W
Force-cooled with external Fan 200W

Output Derating VS Input Voltage

MEAN WELL LOP-200 Series 200W 4 Inch ×2 Inch Low Profile Open Frame Power
Supply 4

Mechanical Specification

MEAN WELL LOP-200 Series 200W 4 Inch ×2 Inch Low Profile Open Frame Power
Supply 5

AC Input Connector (CN1) : JST B3P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1 AC/L JST VHR

or equivalent

| JST SVH-21T-P1.1

or equivalent

2| No Pin
3| AC/N

DC Output Connector (CN2) : JST B6P-VH or equivalent

Pin No. Assignment Mating Housing Terminal
1,2,3 +V JST VHR

or equivalent

| JST SVH-21T-P1.1

or equivalent

4,5,6| -V

FAN Connector(CN101) : JSTB2B-PH-K-S or equivalent

Pin No. Assignment Mating Housing Terminal
1 +12V JST PHR-2

or equivalent

| JST SPH-002T-P0.5S

or equivalent

2| DC COM

Note:
Class Ⅰ System: Mounting holes marked with have to be connected to safety earth.
Class Ⅱ System: Unnecessary to connect with safety earth.

Installation Manual
Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals