Product Information
Specifications
- Product Name: 90W AC-DC PCB-Mount Green Power Module
- Series: IRM-90
- User’s Manual: IRM-90
- Certifications: UL62368-1, IEC62368-1, BS EN/EN60335-1 TPTC004,BS EN/EN62368-1
- Size: 3.43” x 2.05”
- Mounting Options: PCB, chassis, or screw terminal
- Input Voltage: Universal input 80~305VAC
- No Load Power Consumption
Product Usage Instructions
Installation
- Ensure that the input voltage matches the specified range of 80~305VAC.
- Select the appropriate mounting option – PCB, chassis, or screw terminal based on your application.
- Securely mount the power module in the desired location.
Connection
- Connect the input power source within the specified voltage range.
- Connect the output to the intended device or circuit.
- Double-check all connections for accuracy and security.
Operation
- Power on the input source to activate the power module.
- Monitor the device for proper functionality.
- If any issues arise, refer to the user manual for troubleshooting steps.
90W AC-DC PCB-Mount Green Power Module
IRM-90 series
Features
- 3.43″x2.05″compact size
- PCB, chassis or screw terminal mounting version
- Universal input 80~305VAC
- No load power consumption<0.3
- EMI BS EN/EN55032 ClassB without additional components
- Wide operating temp. rage -30~80°C
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- Isolation Class II
- Over voltage category Ill
- Operating attitude up to 4000 meters (Note.7)
- 100W peak(10 sec.)
- 3 years warranty
Applications
- Industrial electrical equipment
- Mechanical equipment
- Factory automation equipment
- Handheld electronic device
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
IRM-90 is a 90W miniature (875229.5mm) AC-DC PCB-mount module type power
supply, ready to be soldered onto the PCB boards of various kinds of
electronic instruments or industrial automation equipments.
This product allows the universal input voltage range of 80~305VAC. The 94V-0
flame retardant plastic case and potted with silicone enhance the heat
dissipation and meet the anti-vibration demand up to 2~5G anti-vibration by
model; moreover, it provides the fundamental resistance to dust and moisture.
With the high efficiency up to 93% and the extremely low no-load power
consumption below 0.3W, IRM-90 series fulfills the worldwide regulation for
the low power consumption requirement for electronics. The entire series is a
Class Il design (no FG pin), incorporating the built-in EMI filtering
components, enabling the compliance with BS EN/EN55032 Class B; the supreme
EMC features keep the end electronic units from from electromagnetic
interference. In addition to the PCB mounting style model, IRM-90 series also
offers the screw terminal style model (ST).
Model Encodina
SPECIFICATION
MODEL | IRM-90-12 | IRM-90-15 | IRM-90-24 | IRM-90-48 |
---|---|---|---|---|
OUTPUT | DC VOLTAGE | 12V | 15V | 24V |
CURRENT
| Peak(10 sec.)| 7.37A| 6.23A| 4.13A| 2.07A
Convection| 6.7A| 5.67A| 3.75A| 1.88A
RATED POWER| Peak(10 sec.) Note.2| 88.4W| 93.5W| 99W| 99.2W
Convection| 80.4W| 85.05W| 90W| 90.2W
RIPPLE & NOISE (max.) **Note.3| 120mVp-p| 150mVp-p| 200mVp-p| 240mVp-p
VOLTAGE TOLERANCE Note.4| ±2.0%| ±2.0%| ±2.0%| ±2.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1000ms, 30ms/230VAC 1000ms, 30ms/115VAC at
full load
HOLD UP TIME (Typ.)| 30ms/230VAC 10ms/115VAC
at full load
INPUT| VOLTAGE RANGE Note.5| 80 ~ 305VAC 113 ~ 431VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 92%| 92.5%| 93%| 93%
AC CURRENT (Typ.)| 1.9A/115VAC 1.1A/230VAC
INRUSH CURRENT (Typ.)| COLD START 30A/115VAC
65A/230VAC
LEAKAGE CURRENT (max.) Note.6| < 0.25mA/240VAC
PROTECTION| **
OVERLOAD
| 115% ~ 160% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is
removed
OVERVOLTAGE
| 12.6 ~ 16.2V| 15.8 ~ 20.3V| 25.2 ~ 32.4V| 50.4 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Protection type : Shut down o/p voltage, re-power on
to recover
ENVIRONMENT| WORKING TEMP.| -30 ~ +80℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP.| -40 ~ +85℃
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
SOLDERING TEMPERATURE| Wave soldering: 265℃,5s (max.); Manual soldering:
390℃,3s (max.)
VIBRATION| Blank:10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each
along X, Y, Z axes
ST:10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
OPERATING ALTITUDE Note.7| Ⅲ; EN62368-1;altitude up to 2000 meters
SAFETY & EMC
(Note 8)
| SAFETY STANDARDS| IEC62368-1, IEC60335-1, Dekra BS EN/EN60335-1,BS
EN/EN62368-1,UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:4KVAC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032 (CISPR32),BS EN/EN55014-1| Class B
Radiated| BS EN/EN55032 (CISPR32),BS EN/EN55014-1| Class B
Harmonic Current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY| BS EN/EN55035, BS EN/EN61000-6-2,BS EN/EN55014-2
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air; Level 2, 4KV contact, criteria A
RF field susceptibility| BS EN/EN61000-4-3| ****
Level 3, criteria A
EFT bursts| BS EN/EN61000-4-4| Level 3, criteria A
Surge susceptibility| BS EN/EN61000-4-5| Level 4,2KV/L-N, criteria A
Conducted susceptibility| BS EN/EN61000-4-6| Level 3, criteria A
Magnetic field immunity| BS EN/EN61000-4-8| Level 4, criteria A
Voltage dip, interruption| ****
BS EN/EN61000-4-11
| >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
OTHERS
| MTBF| 5088.4K hrs min. Telcordia SR-332 (Bellcore) ; 609.9K hrs
min. MIL-HDBK-217F (25℃)
DIMENSION| PCB mounting style : 875229.5mm (LWH)
Screw terminal style : 1095233.5mm (LWH)
PACKING| PCB mounting style : 0.197Kg;60pcs/11.8Kg/0.94CUFT Screw
terminal style :0.219Kg;50pcs/12Kg/0.56CUFT
NOTE
| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
3. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
4. Tolerance : includes set up tolerance, line regulation and load regulation.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. Leakage current was measured from primary input to DC output.
7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
8. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
Block Diagram
Derating Curve
Output Derating VS Input Voltage
Mechanical Specification
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
Frequently Asked Questions (FAQ)
What should I do if the power module does not turn on?
Check the input voltage and connections to ensure they are within the specified ranges and properly secured.
Can I use this power module for outdoor applications?
It is recommended to check the environmental specifications in the user manual to determine suitability for outdoor use.
Is this product suitable for use in high-temperature environments?
Refer to the temperature ratings and guidelines provided in the user manual to ensure proper operation in high-temperature conditions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>