MEAN WELL IRM-90 Series 90W AC and DC PCB Mount Green Power Module Owner’s Manual

June 1, 2024
MEAN WELL

MEAN WELL IRM-90 Series 90W AC and DC PCB Mount Green Power Module

Product Information

Specifications

  • Product Name: 90W AC-DC PCB-Mount Green Power Module
  • Series: IRM-90
  • User’s Manual: IRM-90
  • Certifications: UL62368-1, IEC62368-1, BS EN/EN60335-1 TPTC004,BS EN/EN62368-1
  • Size: 3.43” x 2.05”
  • Mounting Options: PCB, chassis, or screw terminal
  • Input Voltage: Universal input 80~305VAC
  • No Load Power Consumption

Product Usage Instructions

Installation

  1. Ensure that the input voltage matches the specified range of 80~305VAC.
  2. Select the appropriate mounting option – PCB, chassis, or screw terminal based on your application.
  3. Securely mount the power module in the desired location.

Connection

  1. Connect the input power source within the specified voltage range.
  2. Connect the output to the intended device or circuit.
  3. Double-check all connections for accuracy and security.

Operation

  1. Power on the input source to activate the power module.
  2. Monitor the device for proper functionality.
  3. If any issues arise, refer to the user manual for troubleshooting steps.

90W AC-DC PCB-Mount Green Power Module

IRM-90 series

MEAN-WELL-IRM-90-Series-90W-AC-and-DC-PCB-Mount-Green-Power-
Module-7

Features

  • 3.43″x2.05″compact size
  • PCB, chassis or screw terminal mounting version
  • Universal input 80~305VAC
  • No load power consumption<0.3
  • EMI BS EN/EN55032 ClassB without additional components
  • Wide operating temp. rage -30~80°C
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • Isolation Class II
  • Over voltage category Ill
  • Operating attitude up to 4000 meters (Note.7)
  • 100W peak(10 sec.)
  • 3 years warranty

Applications

  • Industrial electrical equipment
  • Mechanical equipment
  • Factory automation equipment
  • Handheld electronic device

GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx

Description
IRM-90 is a 90W miniature (875229.5mm) AC-DC PCB-mount module type power supply, ready to be soldered onto the PCB boards of various kinds of electronic instruments or industrial automation equipments.
This product allows the universal input voltage range of 80~305VAC. The 94V-0 flame retardant plastic case and potted with silicone enhance the heat dissipation and meet the anti-vibration demand up to 2~5G anti-vibration by model; moreover, it provides the fundamental resistance to dust and moisture.
With the high efficiency up to 93% and the extremely low no-load power consumption below 0.3W, IRM-90 series fulfills the worldwide regulation for the low power consumption requirement for electronics. The entire series is a Class Il design (no FG pin), incorporating the built-in EMI filtering components, enabling the compliance with BS EN/EN55032 Class B; the supreme EMC features keep the end electronic units from from electromagnetic interference. In addition to the PCB mounting style model, IRM-90 series also offers the screw terminal style model (ST).

Model Encodina

MEAN-WELL-IRM-90-Series-90W-AC-and-DC-PCB-Mount-Green-Power-
Module-1

SPECIFICATION

MODEL IRM-90-12 IRM-90-15 IRM-90-24 IRM-90-48
OUTPUT DC VOLTAGE 12V 15V 24V

CURRENT

| Peak(10 sec.)| 7.37A| 6.23A| 4.13A| 2.07A
Convection| 6.7A| 5.67A| 3.75A| 1.88A
RATED POWER| Peak(10 sec.) Note.2| 88.4W| 93.5W| 99W| 99.2W
Convection| 80.4W| 85.05W| 90W| 90.2W
RIPPLE & NOISE (max.) **Note.3| 120mVp-p| 150mVp-p| 200mVp-p| 240mVp-p
VOLTAGE TOLERANCE Note.4| ±2.0%| ±2.0%| ±2.0%| ±2.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.0%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE TIME| 1000ms, 30ms/230VAC          1000ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)| 30ms/230VAC                           10ms/115VAC at full load
INPUT| VOLTAGE RANGE Note.5| 80 ~ 305VAC       113 ~ 431VDC
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 92%| 92.5%| 93%| 93%
AC CURRENT (Typ.)| 1.9A/115VAC           1.1A/230VAC
INRUSH CURRENT (Typ.)| COLD START         30A/115VAC 65A/230VAC
LEAKAGE CURRENT (max.) Note.6| < 0.25mA/240VAC
PROTECTION| **

OVERLOAD

| 115% ~ 160% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed


OVERVOLTAGE

| 12.6 ~ 16.2V| 15.8 ~ 20.3V| 25.2 ~ 32.4V| 50.4 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT| WORKING TEMP.| -30 ~ +80℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP.| -40 ~ +85℃
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
SOLDERING TEMPERATURE| Wave soldering: 265℃,5s (max.); Manual soldering: 390℃,3s (max.)
VIBRATION| Blank:10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
ST:10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
OPERATING ALTITUDE Note.7| Ⅲ; EN62368-1;altitude up to 2000 meters
SAFETY & EMC

(Note 8)

| SAFETY STANDARDS| IEC62368-1, IEC60335-1, Dekra BS EN/EN60335-1,BS EN/EN62368-1,UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE| I/P-O/P:4KVAC
ISOLATION RESISTANCE| I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH




EMC EMISSION

| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032 (CISPR32),BS EN/EN55014-1| Class B
Radiated| BS EN/EN55032 (CISPR32),BS EN/EN55014-1| Class B
Harmonic Current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| —–
EMC IMMUNITY| BS EN/EN55035, BS EN/EN61000-6-2,BS EN/EN55014-2
Parameter| Standard| Test Level / Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air; Level 2, 4KV contact, criteria A
RF field susceptibility| BS EN/EN61000-4-3| ****

Level 3, criteria A

EFT bursts| BS EN/EN61000-4-4| Level 3, criteria A
Surge susceptibility| BS EN/EN61000-4-5| Level 4,2KV/L-N, criteria A
Conducted susceptibility| BS EN/EN61000-4-6| Level 3, criteria A
Magnetic field immunity| BS EN/EN61000-4-8| Level 4, criteria A
Voltage dip, interruption| ****

BS EN/EN61000-4-11

| >95% dip 0.5 periods, 30% dip 25 periods,

>95% interruptions 250 periods


OTHERS

| MTBF| 5088.4K hrs min.       Telcordia SR-332 (Bellcore) ; 609.9K hrs min.       MIL-HDBK-217F (25℃)
DIMENSION| PCB mounting style : 875229.5mm (LWH) Screw terminal style : 1095233.5mm (LWH)
PACKING| PCB mounting style : 0.197Kg;60pcs/11.8Kg/0.94CUFT       Screw terminal style :0.219Kg;50pcs/12Kg/0.56CUFT







NOTE

| 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.

3. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.

4. Tolerance : includes set up tolerance, line regulation and load regulation.

5. Derating may be needed under low input voltages. Please check the derating curve for more details.

6. Leakage current was measured from primary input to DC output.

7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

8. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”

(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Block Diagram

MEAN-WELL-IRM-90-Series-90W-AC-and-DC-PCB-Mount-Green-Power-
Module-2

Derating Curve

MEAN-WELL-IRM-90-Series-90W-AC-and-DC-PCB-Mount-Green-Power-
Module-3

Output Derating VS Input Voltage

Mechanical Specification

MEAN-WELL-IRM-90-Series-90W-AC-and-DC-PCB-Mount-Green-Power-
Module-5

MEAN-WELL-IRM-90-Series-90W-AC-and-DC-PCB-Mount-Green-Power-
Module-6

Installation Manual

Please refer to : http://www.meanwell.com/manual.html

Frequently Asked Questions (FAQ)

What should I do if the power module does not turn on?

Check the input voltage and connections to ensure they are within the specified ranges and properly secured.

Can I use this power module for outdoor applications?

It is recommended to check the environmental specifications in the user manual to determine suitability for outdoor use.

Is this product suitable for use in high-temperature environments?

Refer to the temperature ratings and guidelines provided in the user manual to ensure proper operation in high-temperature conditions.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MEAN WELL User Manuals

Related Manuals