BEGA 84 851 Surface Floodlight UniLink Instruction Manual

June 1, 2024
BEGA

Specifications:

  • Power consumption: 0.1 A
  • Lamp Module connected wattage: 17.6 W
  • Luminaire connected wattage: 20.5 W
  • Rated temperature: ta max = 25-45
  • Ambient temperature: ta max = 25-45
  • Colour temperature: 3000 K (for LED-0313/930), 4000 K (for LED-0313/940)
  • Colour rendering index (CRI): >90
  • Module luminous flux: 2780 lm (for LED-0313/930), 2940 lm (for LED-0313/940)
  • Luminaire luminous flux: 2170 lm (for LED-0313/930), 2295 lm (for LED-0313/940)
  • Luminaire luminous efficiency: 105.9 lm/W (for LED-0313/930), 112 lm/W (for LED-0313/940)

Product Usage Instructions

  • Safety Instructions:
    Ensure to follow national safety regulations for installation and operation. The manufacturer is not liable for damage due to improper use or installation. Any modifications should be made by authorized personnel.

  • Overvoltage Protection:
    The luminaire’s electronic components have overvoltage protection according to DIN EN 61547. For additional protection against transients, separate overvoltage protection components are recommended and can be found on the manufacturer’s website.

Installation:

  1. Unscrew the hexagon socket screws using a 3 mm wrench on the sides of the connection adapter.
  2. Attach the corresponding accessory to the floodlight and tighten to a torque of 5 Nm.

Maintenance :
Regularly check the connecting cable for external damage. Only a qualified electrician should replace the cable if necessary.

Accessories :
Various country-specific mains plugs with a 0.5 m connecting cable are available for fitting to floodlights with a connection adapter. Choose the appropriate plug type based on your region.

FAQ :

  • Q: Can I remove the desiccant bag from the luminaire housing?
    A: No, the desiccant bag should not be removed as it is essential for removing residual moisture.

  • Q: What should I do if I notice external damage to the connecting cable?
    A: If you see any external damage on the connecting cable, it should only be replaced by a qualified electrician.

Technical amendments reserved
BEGA UniLink® Surface floodlight BEGA UniLink®

84 851

IP 65

BEGA-84-851-Surface-Floodlight-UniLink- \(1\)

Instructions for use

Application

  • Surface floodlight BEGA UniLink® with connection adapter for use in combination with various accessories, e.g. for mounting on trees, pipes or wooden structures.
  • A separate mains plug must be ordered in order to connect the floodlight to the mains. The various country-specific mains plugs with 0.5 m connecting cable, as well as extension  cables and five-way distribution boxes are available as accessories.

Product description

  • Floodlight made of aluminium alloy, aluminium and stainless steel
  • BEGA Unidure® coating technology
  • Colour graphite, silver or white
  • Safety glass with optical structure
  • Silicone gasket
  • Reflector made of pure anodised aluminium Rotation range of floodlight 360°
  • Swivel range -35°/+90° 5 m mains supply cable
  • X05RN-F FEP 2 × 1@ + 1G2,5@ with
  • BEGA UniLink® plug-in connector
  • Complies with flicker requirements in accordance with IEEE 1789,
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit 220-240 y 50-60 Hz
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets Impact strength IK07
  • Protection against mechanical impacts < 2 joule
  • Conformity mark
  • Weight: 1.8 kg
  • This product contains light sources of energy efficiency class(es)

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Total load

  • When configuring your lighting system, please ensure that the maximum power consumption of 6 A is not exceeded. Information on power consumption can be found in the instructions for use and data sheets for all BEGA UniLink® luminaires.
  • Power consumption of 84 851: 0,1 A

Lamp

  • Module connected wattage 17.6 W
  • Luminaire connected wattage 20.5 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 45 °C

84 851 K3

  • Module designation LED-0313/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 2780 lm
  • Luminaire luminous flux 2170 lm
  • Luminaire luminous efficiency 105,9 lm / W

84 851 K4

  • Module designation LED-0313/940
  • Colour temperature 4000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 2940 lm
  • Luminaire luminous flux 2295 lm
  • Luminaire luminous efficiency 112 lm / W

Light technique

  • Broad spread light distribution.
  • Half beam angle 76/89°

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against
  • e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at
  • www.bega.com.
  • Caution:
  • The BEGA UniLink® plug connectors may only be connected and disconnected in a voltage-free state.

Installation

  • Unscrew the hexagon socket screws (wrench size 3 mm) on the sides of the connection adapter and screw the corresponding accessory to the floodlight.
  • Torque = 5 Nm.
  • Plug the floodlight’s connecting cable into the plug contact of the connecting cable with the country-specific mains plug, or into the distribution box or extension cable.
  • To ensure a sufficiently low protective conductor resistance (loop resistance), the connecting cable of each luminaire in the system must not exceed a length of 50 m from the entry point.

Adjustment of beam direction:

  • Undo joint screw (hexagon socket head wrench size 5 mm) and set the desired beam direction.
  • Tighten the joint screw.
  • Torque = 7 Nm.

Please note:

  • Do not remove the desiccant bag from the luminaire housing.
  • It is needed to remove residual moisture.

Cleaning · Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high pressure cleaners.

Maintenance
The connecting cable must be checked for external damage and may only be replaced by a qualified electrician.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Close the luminaire.

Accessories

  • The following combination options are available for fitting to floodlights with connection adapter:
  • 71 223 Screw clamp with connection adapter 71 224 Tube clamp with connection adapter 71 225 Lashing strap with connection adapter 71 226 General fastener with connection adapter
  • 71 227 G½ mount with connection adapter 70 500 Shield
  • Country-specific mains plugs with 0.5 m connecting cable
  • 71 180 Plug type F / E: system common in Germany and Europe
  • 71 181 Plug type G: system used in Great Britain (“Commonwealth plug”)
  • 71 182 Plug type J: system common in Switzerland and Liechtenstein
  • 71 183 Plug type L: system common in Italy and Greece
  • 71 184 Plug type K: system common in

Denmark and Greenland

  • 71 186 BEGA UniLink® Extension cable 5 m 71 187 BEGA UniLink® Extension cable 10 m 71 188 BEGA UniLink® Extension cable 20 m
  • 71 247 Connecting cable 5 m with free line ends
  • 71 256 Connecting cable 0.5 m with free line ends
  • 71 189 BEGA UniLink® Five-way distribution box
  • For the accessories a separate instructions for use can be provided upon request.

Spares

  • Spare glass 14 000 966
  • LED power supply unit DEV-0402/700
  • LED module 3000 K LED-0313/930
  • LED module 4000 K LED-0313/940
  • Reflector 76 001 194
  • Gasket glass 83 001 372
  • Gasket ousing 83 001 386

BEGA  31 60

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals