MEAN WELL WDR-60 Series 60W Ultra Wide Input Industrial DIN Rail Power Supply Owner’s Manual
- June 3, 2024
- MEAN WELL
Table of Contents
- MEAN WELL WDR-60 Series 60W Ultra Wide Input Industrial DIN Rail Power
- Features
- Model Encoding
- SPECIFICATION
- Block Diagram
- Derating Curve
- Static Characteristics
- DC OKA Relay Contact
- Mechanical Specification
- Installation Instruction
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MEAN WELL WDR-60 Series 60W Ultra Wide Input Industrial DIN Rail Power
Supply
Features
- 180 550Vac ultra-wide input for 1-phase or 2-phase
- 32mm slim width
- 4.7KVac VO high isolation (Reinforced isolation)
- Protections: Short circuit / Overload/ Over voltage / Over temperature
- Cooling by free air convection
- Can be installed on DIN rail TS-35/7.5 or 15
- -30~+85 C ultra-wide operating temperature (>+60°C derating)
- Overvoltage category I
- DC OK relay contact
- DC output voltage adjustable(+20%)
- 3 years warranty
Applications
- Industrial control system
- Semiconductor fabrication equipment
- Factory automation
- Electro-mechanical apparatus
GTIN CODE
MW Search: https://www.meanwell.com/serviceGTIN.aspx
Description
WDR-60 series is a 60W DIN rail power supply with ultra-wide AC input range.
It is suitable to be mounted on TS-35/7.5 or TS-35/15 rails. Main features are
as following: it can accept 180-550Vac ultra-wide input voltage range for
single phase or 2-phase system, easy to install DIN rail type, narrow width
(32mm) in slim design,-30+85°C wide range operating temp, 4.7KVAC high
isolation voltage, operation at 2000m altitude, adjustable output voltage
(+20% max.), high efficiency, low ripple & noise, complete protections and so
on. WDR-60 is compliant with BS EN/EN-61000-6-2 standard regarding immunity
for industrial environments. It suitable for industrial automation,
surveilance, telecommunication and more applications.
Model Encoding
SPECIFICATION
MODEL | WDR-60-5 | WDR-60-12 | WDR-60-24 | WDR-60-48 |
---|
OUTPUT
| DC VOLTAGE| 5V| 12V| 24V| 48V
RATED CURRENT| 10A| 5A| 2.5A| 1.25A
CURRENT RANGE| 0 ~ 10A| 0 ~ 5A| 0 ~ 2.5A| 0 ~ 1.25A
RATED POWER| 50W| 60W| 60W| 60W
RIPPLE & NOISE (max.) **Note.2| 100mVp-p| 120mVp-p| 150mVp-p| 200mVp-p
VOLTAGE ADJ. RANGE| 5 ~ 6V| 12 ~ 15V| 24 ~ 29V| 48 ~ 57V
VOLTAGE TOLERANCE ****Note.3| ±2%| ±1.5%| ±1.0%| ±1.0%
LINE REGULATION| ±0.5%| ±0.5%| ±0.5%| ±0.5%
LOAD REGULATION| ±1.5%| ±0.5%| ±0.5%| ±0.5%
SETUP, RISE, HOLD UP TIME**| 1000ms, 70ms, 20ms/400Vac 2000ms,
70ms, 10ms/230Vac at full load
INPUT
| VOLTAGE RANGE Note.4| 180 ~ 550Vac or 254 ~ 780Vdc
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 83.5% / 400Vac| 86.5% / 400Vac| 89% / 400Vac| 90.5% /
400Vac
AC CURRENT| 0.4A/400Vac 0.7A/230Vac
INRUSH CURRENT (max.)| COLD START 50A /400Vac 30A/230Vac
LEAKAGE CURRENT| <2mA / 530Vac
PROTECTION
| OVERLOAD| 105 ~ 135% rated output power
Hiccup mode when output voltage <50%, recovers automatically after fault
condition is removed
Constant current limiting recovers automatically after fault condition is removed
OVER VOLTAGE| 6.2 ~ 7.2V| 16 ~ 18V| 31 ~ 37V| 58 ~ 60.5V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Protection type : Shut down o/p voltage, re-power on
to recover
FUNCTION| DC OK SIGNAL| Relay contact rating(max.) : 30V / 1A
resistive
ENVIRONMENT
| WORKING TEMP.| -30 ~ +85℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 90% RH non-condensing
STORAGE TEMP.| -40 ~ +85℃
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 60℃)
VIBRATION| Component: 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X,
Y, Z axes; Mounting clip: Compliance to IEC60068-2-6
OPERATING ALTITUDE Note.5| 2000 meters
OVER VOLTAGE CATEGORY| Ⅲ; According to EN61558, EN50178, EN60664-1,
EN62477-1, EN60204-1; altitude up to 2000 meters
SAFETY & EMC
(Note 7)
| SAFETY STANDARDS| UL61010, BS EN/EN61558-2-16, AS/NZS 62368.1, EAC TP
TC 004 approved; design refer to GL and BS EN/EN60204-1(By request)
WITHSTAND VOLTAGE| I/P-O/P:4.7KVAC I/P-FG:2.5KVAC O/P-FG:0.5KVAC
O/P-DC OK:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/
70% RH
EMC EMISSION
| Parameter| Standard| Test Level / Note
Conducted| BS EN/EN55032(CISPR32)| Class B
Radiated| BS EN/EN55032(CISPR32)| Class B
Harmonic Current| BS EN/EN61000-3-2| Class A
Voltage Flicker| BS EN/EN61000-3-3| ——-
EMC IMMUNITY
| BS EN/EN55024, BS EN/EN55035, BS EN/EN61000-6-2, BS EN/EN61204-3
Parameter| Standard| Test Level /Note
ESD| BS EN/EN61000-4-2| Level 3, 8KV air; Level 2, 4KV contact, criteria A
Radiated Susceptibility| BS EN/EN61000-4-3| Level 3, 10V/m, criteria A
EFT Bursts| BS EN/EN61000-4-4| Level 3, 2KV/5KHz, criteria A
Surge| BS EN/EN61000-4-5| Level 4, 2KV/Line-Line, 4KV/Line-Earth, criteria A
Conducted| BS EN/EN61000-4-6| Level 3, 10V, criteria A
Magnetic Field| BS EN/EN61000-4-8| Level 4, 30A/m, criteria A
Voltage Dips and interruptions| BS EN/EN61000-4-11| >95% dip 0.5 periods, 30%
dip 25 periods,
>95% interruptions 250 periods
OTHERS
| MTBF| 1900.1K hrs min. Telcordia SR-332 (Bellcore) ; 313.7K hrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 32125.2102mm (WHD)
PACKING| 0.45Kg; 28pcs/13.6Kg/1.24CUFT
NOTE
|
- All parameters NOT specially mentioned are measured at 400VAC input, rated load and 25C of ambient temperature.
- Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1í 8& 47f parallel capacitor.
- Tolerance : includes set up tolerance, line regulation and load regulation.
- Derating may be needed under low input voltage. Please check the derating curve for more details.
- The ambient temperature derating of 3.5 C/1000m with fanless models and of 5 C/1000m with fan models for operating altitude higher than 2000m(6500ft).
- Installation clearances: 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.
- The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
https://[www.meanwell.com/serviceDisclaimer.aspx](http://www.meanwell.com/serviceDisclaimer.aspx)
Block Diagram
Derating Curve
Static Characteristics
DC OKA Relay Contact
- Contact Close
- Contact Open
- Contact Ratings (max.)
- PSU turns ON / DC OK.
- PSU turns OFF / DC Fail.
- 30V/1A resistive load.
Mechanical Specification
Installation Instruction
Installation Manual
Please refer to: http://www.meanwell.com/manual.html
Read User Manual Online (PDF format)