MEAN WELL EDR-150-24 150W Single Output Industrial DIN RAIL Owner’s Manual
- June 3, 2024
- MEAN WELL
Table of Contents
MEAN WELL EDR-150-24 150W Single Output Industrial DIN RAIL
Features
- Universal AC input/ Full range
- Protections: Short circuit/Overload/ Over voltage/ Over temperature
- Cooling by free air oonvection
- Can be installed on DIN rail TS-35/7.5 or 15
- UL 508 (industrial control equipment) approved
- BS EN/EN61000-6-2(Bs EN/EN50082-2) industrial immunity level
- 100 % full load burn-in test
- 2 years warranty
Applications
- Industrial control system
- Semiconductor fabrication equipment
- Factory automation
- Electro-mechanical apparatus
GTIN CODE
MW Search : https://www.meanwell.com/serviceGTIN.aspx
Description
- EDR-150-24 is one economical slim DIN rail power supply series, providing up to 156W at 230VAC input. This series is adapt to be installed on TS-35/7.5 or TS-35/15 mounting rails. The body is designed 40mm in width, which allows space saving inside the cabinets. The entire series adopts the full range AC input from 90VAC to 264VAC and conforms to BS EN/EN61000-3-2(S80% Load), the norm the European Union regulates for harmonic current.
- EDR-150-24 is designed with metal housing that enhances the unit’s power dissipation. With working efficiency up to 87%, the entire series can operate at the ambient temperature between -20C and 60C under air convection. It is equipped with constant current mode for over-load protection, fitting various inductive or capacitive applications. The complete protection functions and relevant certificates for industrial control apparatus (UL508, TUV BS EN/EN62368-1, and etc.) make EDR-150-24 a very competitive power supply solution for industrial applications.
Model Encoding
SPECIFICATION
MODEL | EDR-150-24 |
---|
OUTPUT
| DC VOLTAGE| 24V
RATED CURRENT| 6.5A / 230VAC 5.2A / 115VAC
CURRENT RANGE| 0 ~ 6.5A / 230VAC 0 ~ 5.2A / 115VAC
RATED POWER| 156W / 230VAC 125W / 115VAC
RIPPLE & NOISE (max.) Note.2| 150mVp-p
VOLTAGE ADJ. RANGE| 24 ~ 28V
VOLTAGE TOLERANCE Note.3| ±1.0%
LINE REGULATION| ±0.5%
LOAD REGULATION| ±1.0%
SETUP, RISE TIME| 1500ms, 60ms/230VAC 3000ms, 60ms/115VAC
at full load
HOLD UP TIME (Typ.)| 16ms/230VAC 10ms/115VAC at full
load
INPUT
| VOLTAGE RANGE **Note.6| 90 ~ 264VAC 127 ~ 370VDC
[DC input operation possible by connecting AC/L(+), AC/N(-)]
FREQUENCY RANGE| 47 ~ 63Hz
EFFICIENCY (Typ.)| 87%
AC CURRENT (Typ.)| 2.6A/115VAC 1.7A/230VAC
INRUSH CURRENT (Typ.)| 20A/115VAC 35A/230VAC
LEAKAGE CURRENT**| <1mA / 240VAC
PROTECTION
| ****
OVERLOAD **Note.7**
| 105 ~ 130% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed / 230VAC
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed / 115VAC
OVER VOLTAGE| 29 ~ 33V
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE| Shut down o/p voltage, re-power on to recover
ENVIRONMENT
| WORKING TEMP.| -20 ~ +60℃ (Refer to “Derating Curve”)
WORKING HUMIDITY| 20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY| -40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT| ±0.03%/℃ (0 ~ 50℃)
VIBRATION| Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X,
Y, Z axes; Mounting: Compliance to IEC60068-2-6
SAFETY & EMC
(Note 4)
| SAFETY STANDARDS| UL508, TUV BS EN/EN62368-1, EAC TP TC 004, BSMI
CNS14336-1 approved;(meet BS EN/EN60204-1)
WITHSTAND VOLTAGE| I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE| I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC /
25℃/ 70% RH
EMC EMISSION| Compliance to BS EN/EN55032 (CISPR32) Class A, BS
EN/EN61000-3-2, Class A (≦80% Load), BS EN/EN61000-3-3, EAC TP TC 020,
CNS13438 Class A
EMC IMMUNITY| Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS
EN/EN55024, BS EN/EN61000-6-2 (BS EN/EN50082-2),
heavy industry level, EAC TP TC 020
OTHERS
| MTBF| 2717.1K hrs min. Telcordia SR-332 (Bellcore) ; 472.5K hrs
min. MIL-HDBK-217F (25℃)
DIMENSION| 40125.2113.5mm (WHD)
PACKING| 0.6Kg; 20pcs/13Kg/1.16CUFT
NOTE
| 1. All parameters NOT specially mentioned are measured at 230VAC Input,
rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted
pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load
regulation.
4. The power supply is considered a component which will be installed into a
final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Installation clearances:40mm on top, 20mm on the bottom, Smm on the left
and right side are recommended when loaded permanently with full power.
In case the adjacent device is a heat source, 15mm clearance is recommended.
6. Derating may be needed under low input voltage. Please check the derating
curve for more details.
7. Hiccup mode at 90-100VAC, recovers automatically after fault condition is
removed.
8. The ambient temperature derating of 3.5 C/1000m with fanless models and of
5C/1000m with fan models for operating altitude higher than 2000m(6500ft).
Product Liability Disclaimer: For detailed information, please refer to
https://www.meanwell.com/serviceDisclaimer.aspx
Block Diagram
Derating Curve
Static Characteristics
Mechanical Specification
Installation Instruction
This series fits DIN rail TS35/7.5 or TS35/15. For installation details, please refer to the Instruction manual.
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
File Name: EDR-150-24-SPEC 2022-02-28
Downloaded from Arrow.com.
Read User Manual Online (PDF format)