Roth Pro1 Leak Alarm and Leak Detector Instruction Manual

June 1, 2024
Roth

Roth Pro1 Leak Alarm and Leak Detector Instruction Manual

Roth Pro1 Leak Alarm and Leak Detector Instruction
Manual

Roth Pro1 Leak Alarm and Leak Detector Instruction Manual - Product
Overview

  1. Control unit
  2. Solenoid valve
  3. Pressure sensor
  4. Power adapter
  5. Flow sensor
  6. Installation manual
  7. Quick Guide

Notice!

Installation manual for installers
Installation of Roth QuickStop Pro1 must be performed by a professional installer. Installation must be in accordance with national and local codes and requirements. The valve unit must be installed in a frost free environment. Inlet water pressure should not exceed 10 bar and the unit will function with water temperatures between 0 ­ 90°C. The solenoid valve and sensor unit are paired to a unit and pressure tested before delivery. The manufacturer’s warranty will be void if this assembly is modified.

Important! Safety equipment using water (e.g. fire sprinklers), must be ensured its supply of water and must be supplied from before the QuickStop Pro1 and thus cannot not be connected to the pipe network protected by QuickStop Pro1.

Warranty
The unit must be installed in accordance with these instructions, in order for the product warranty to be effective. The functioning of the product depends on its correct installation. No parts, such as dirt filter included in the set, may be left out or substituted, e.g. with parts priorly installed.

Roth QuickStop Pro1 without Wi-Fi access
Roth QuickStop Pro1 can be installed without Wi-Fi access. The tap water installation will still be protected by Roth QuickStop Pro1, even though app and cloud functions are not in use and notifications not available. To have full utilization of your system we strongly recommend connecting to the app and cloud.

Roth QuickStop Pro1 with Wi-Fi access
Ensure you have access to a good Wi-Fi signal from the position, where the display unit will be mounted. One way of doing could be trying to connect a smart phone or tablet to the Internet via the Wi-Fi at that precise location. Succeeding with that will likely ensure the connecting of QuickStop Pro1 to Roth app and cloud service.

NOTE! It is not enough just to check the Wi-Fi signal strength on the mobile device since this only applies to signal reception. In order to ensure the wireless connection is functioning, the best way is to check the transmission by actually using the Wi-Fi network.

Installation of product

  1. Close the stop valve of the water inlet.

  2. Then flush the pipes carefully by gently opening the stop valve, until no particles can be seen in the flushing water, before installing the QuickStop Pro1.

  3. Any accessories supplied with the product package are manufactured of brass approved for pressurized tap water. In order to avoid corrosion caused by galvanic current, never use any parts or materials, which are galvanized, zinc-plated or made of black steel for mounting purposes.

  4. The QuickStop Pro1 unit should be installed after the water meter, and as early as possible in the pipe system. The arrow on the solenoid valve shows the direction of the flow of water. Be extremely careful when cutting any pipes for mounting purposes, and make sure that no thread seal tape or flax fibers are left inside the pipes, which could be carried by water into the valve unit and prevent the Leakomatic sensor from working.

  5. The QuickStop Pro1 can be mounted freely on either a horizontal or a vertical pipe.

  6. However in order to prevent particles from getting into the coil shaft, if possible, mount the valve unit so the coil is facing upwards.

  7. The valve unit should be mounted so that it is not affected by any lateral or longitudinal compression, torsion, or traction forces.

  8. Gently reopen the stop valve at the water inlet.

  9. Visually inspect the installation to ensure water tightness of the assembly work.
    We recommend installing a ball valve right after the QuickStop-unit for easier maintenance operations. It is also recommendable to mount a check valve on the cold water supply pipe.

Be aware of national ruler regarding use of check valves in tap water installation.

Mounting of wiring harnesses

Mounting of the control unit and its connection to the pressure sensor is normally carried out before the delivery. Always disconnect power from the control unit before dismantling from the valve unit to prevent power surges that could damage the electronic components.

  1. Check that the pressure sensor’s plug is connected to the sensor and the other end is connected to the “Sensor” connector on the control unit.

  2. The power adaptor is connected to the socket and the connector “Power” of the control unit.

After installation
Check that …

The unit does not register any flow when water supply is turned off.
The test indicator’s blue light is on when water is running continuously.
The blue LED goes off shortly after the tap is closed.
To carry out the functionality test
1. By setting the system into “Away” mode.
2. By opening a tap and let the water run until the flow is registered. Shortly after the valve unit will shut off the water and the red alarm LED lights up. If the alarm audio is activated, you will also hear the alarm sound.
Warnings and alarms can be reset with the “Reset” button. One short press turns off the alarm sound, while holding down the button will reset the respective alarm.

The troubleshooting and leak detection guide are available on our website at www.Roth.Support/QuickStop_Pro_UK

Maintenance
The dirt filter should minimum be cleaned once a year. Pour some clean water in a bucket or the like, then shut the stop valve and remove the dirt filter’s strainer, clean it by using a small brush like e.g. a toothbrush and rinse it in the clean water.

Reassemble the parts and gently turn the water back on.

After any maintenance always check that the valve unit shuts off the flow of water correctly by carrying out a functionality test.

ROTH DANMARK A/S · Tlf. +45 47 38 01 21 · E-mail: service@roth- danmark.dk · roth-danmark.dk
ROTH SVERIGE AB · Tel. +46 40 53 40 90 · E-mail: service@roth- sverige.se · roth-sverige.se
ROTH NORGE AS · Tel. +47 67 57 54 00 · E-mail: service@roth- norge.no · roth-norge.no
ROTH FINLAND OY · Puh. +358 (0)19 440 330 · S-posti: service@roth- finland.fi · roth-finland.fi
ROTH UK Ltd. · Phone +44 (0) 1905 453424 · E-mail: enquiries@roth- uk.com · roth-uk.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Roth User Manuals

Related Manuals