olympia electronics BS-655 Optical Smoke Detector Instructions
- June 12, 2024
- olympia electronics
Table of Contents
olympia electronics BS-655 Optical Smoke Detector Instructions
Thank you for your trust in our products.
Olympia Electronics – European manufacturer.
GENERAL
Before installing the detector, the user must read these instructions
carefully and store this manual for future reference.
The detectors BS-655 were created to offer quick detection in case of fire.
They have two parts, one plastic base which is installed on the ceiling and
the main unit of the detector which is fastened to the base by a simple
turning to the right. The detectors have an indication led which lights
continuously in case of fire detection until there is a reset signal from the
panel. The indication led also flashes every 4 sec to indicate good operation.
These detectors can cooperate with conventional fire alarm panels like BS-632
and BS-636.
OPERATION CHECK
The operation check can be done by spraying a small amount of smoke into the
detector’s chamber. You can use the special smoke device A-752 of our company,
or a similar device.
It is advised to conduct a good operation test every 6 months and every time
the detector position is changed.
It is essential to have good air circulation inside the detector. Therefore
care must be taken so that the vents of the detector are not covered.
NOTE
The detectors must be placed in the ceiling on visible areas with no side
obstacles and away from sides with no air circulation or strong air currents
and vapors. Each detector covers almost 50 m and the distance between two
detectors must not exceed 15m. Also the detectors must be placed away from
fluorescent tubes at least 50 cm The cables cross section must be from 0.5 to
2 1.5mm .
ATTENTION!!
After the device is installed, care must be taken, so that the detector
vents are not blocked by anything (i.e. dust, paint). Failing to do so will
prevent the smoke particles to enter the detection chamber.
After the installation, it is the sole responsibility of the user to maintain
the detector for good operation.
- Detach the detector from it’s base by turning it anticlockwise until the side marks are aligned.
- Install the base with the included mounting parts (point 5).
- Connect the power cables (respect to polarity) according to the installation requirements (figure 1,2).
- Place carefully the detector, so as to align the side marks and turn it clockwise all the way.
Power the device and after 3-5 seconds will be ready to operate.
TECHNICAL CHARACTERISTICS
CONNECTION
- IN-OUT -L : It is connected to the zone of the panel or to the (IN-OUT -L) contact of the previous detector.
- OUT +R : It is connected to the next detector (IN +L) or if it is the last one to the terminal resistor.
- OUT +R and -R : It is connected with BS-572.
- IN +L : It is connected to the zone of the panel or to the (OUT +R) contact of the previous detector.
WARRANTY
Olympia Electronics guarantees the quality, condition and operation of the
goods. The period of warranty is specified in the official catalogue of
Olympia Electronics and also in the technical leaflet, which accompanies each
product. This warranty ceases to exist if the buyer does not follow the
technical instructions included in official documents given by Olympia
Electronics or if the buyer modifies the goods provided or has any repairs or
re-setting done by a third party, unless Olympia Electronics has fully agreed
to them in writing. Products that have been damaged can be returned to the
premises of our company for repair or replacement, as long as the warranty
period is valid.
Olympia Electronics reserves the right to repair or to replace the returned
goods and to or not charge the buyer depending on the reason of defection.
Olympia Electronics reserves the right to charge or not the buyer the
transportation cost.
P.C. 60061 Greece
HEAD OFFICE
72nd km. O.N.R. Thessaloniki-Katerini
www.olympia-electronics.com
info@olympia-electronics.gr
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>