Eltako EUD62NPN-IPM-110-240V Universal dimming actuator Instructions

June 1, 2024
Eltako

Eltako EUD62NPN-IPM-110-240V Universal dimming actuator

Product Information

Specifications

  • Model: EUD62NPN-IPM/110-240V
  • Universal dimming actuator
  • Input Voltage: 110-240V
  • IP Rating: IP

Product Usage Instructions

Installation

Only skilled electricians should install this electrical equipment to prevent the risk of fire or electric shock. Follow the installation guidelines provided in the user manual.

Operation

Ensure the input voltage matches the specified range (110-240V) before use. Connect the dimming actuator according to the wiring diagram provided in the manual. Test the functionality before finalizing the installation.

Maintenance

Regularly inspect the dimming actuator for any signs of damage or wear. Clean the unit as needed to ensure proper operation. Do not attempt to repair or modify the equipment yourself; always contact a qualified technician.

FAQ

Q: Can I install the dimming actuator myself?

A: It is recommended that only skilled electricians handle the installation to avoid any risks of fire or electric shock.

Q: What should I do if the dimming actuator is not functioning properly?

A: Check the wiring connections and power supply to ensure everything is properly set up. If issues persist, contact a professional for assistance.

Universal dimming actuator IP EUD62NPN-IPM/110-240V

Only skilled electricians may install this electrical equipment otherwise there is the risk of fi re or electric shock!

Temperature at mounting location: -20°C up to +50°C.
Storage temperature: -25°C up to +70°C.
Relative humidity: annual average value <75%.

ELTAKO Connect App download

Eltako-EUD62NPN-IPM-110-240V-Universal-dimming-actuator-
fig-1

https://eltako.com/redirect/eltako-connect

  • Universal dimming actuator IP via Wi-Fi. Matter-certifi ed, REST-API. With power MOSFET. Dimmable 230 V LED lamps in ‘phase cut-off’ mode up to 300 W or in ‘phase control’ mode up to 100 W depending on ventilation conditions. 230 V incandescent lamps and halogen lamps up to 300 W depending on ventilation conditions. No minimum load. Only 0.7 watt standby loss. For installation. 49 x 51 mm wide, 25 mm deep. The terminals are plug-in terminals for conductor cross-sections of 0.2 mm2 to 2.5 mm2.
  • Zero passage switching with soft ON and soft OFF to protect lamps.
  • Supply voltage, switching voltage and control voltage local 110-240 V.
  • The brightness level is stored on switch-off (memory).
  • If supply voltage fails, the device is switched off in defi ned mode.
  • Automatic electronic overload protection and overtemperature switch-off.
  • With control input for a mains voltage control button that may be installed in front of it. Glow lamp current is not permitted.
  • This actuator is Matter certifi ed and can there-fore be taught-in into different ecosystems and operated in parallel.

Typical connection

First setup with Apple Home

  • Only 2.4 GHz Wi-Fi frequency bands are supported.
  • Recommended: Commissioning close to the main router.
  1. Apply mains voltage and wait for the signal tone.
  2. Wait 15 seconds until the device has started.
  3. Open the Apple Home app.
  4. In the upper right corner press the ‘+’ symbol and select ‘Add device’.
  5. Scan the Matter QR code. It can be found on the back of the device and on the QR code card in the packaging.
  6. The Apple Home app will guide you through the remaining steps.

First set up with Google Home

  • Only 2.4 GHz Wi-Fi frequency bands are supported.
  • Recommended: Commissioning close to the main router.
  1. Apply mains voltage and wait for the signal tone.
  2. Wait 15 seconds until the device has started.
  3. Download and open the Google Home app.
  4. Click on ‘Devices’ at the bottom of the screen.
  5. Press ‘+ Add’ in the bottom right corner.
  6. Now click on ‘New device’.
  7. The Apple Home app will guide you through the remaining steps.

First setup with Amazon Alexa

  • Only 2.4 GHz Wi-Fi frequency bands are supported.
  • Recommended: Commissioning close to the main router.
  1. Apply mains voltage and wait for the signal tone.
  2. Wait 15 seconds until the device has started.
  3. Download and open the Amazon Alexa app.
  4. Click on ‘Devices’ at the bottom of the screen.
  5. In the bottom right corner press the ‘+’ symbol and select ‘Add Device.
  6. Click on your automatically recognised ELTAKO device.
  7. The Amazon Alexa app will guide you through the remaining steps.

Important!
If an update is available and the device is idle, the installation will occur immediately, fol-lowed by a device restart.

Factory reset:
3 short and 3 long beeps will beep to confi rm the reset:

Option 1:
Via the ELTAKO Connect app.

Option 2:

  1. Apply supply voltage (time window of 5 minutes begins)
  2. Connected switch/button: press 8x briefl y (< 1 sec.) and 1x long (> 1.5 sec. and < 5 sec.). A signal tone sounds for the last two short closing actions. The reset confi rmation beeps are delayed by 15 seconds with this option.
    Outside of the time window, the device is simply restarted!

Option 3:

  1. The device is disconnected from the supply voltage.
  2. Apply supply voltage, wait for the signal tone and disconnect the supply voltage within 5 seconds.
  3. Repeat step 2 a total of 5 times.
  4. The sixth time the supply voltage is switched on, the successful factory reset is confi rmed by 3 short and 3 long beeps.

Over-the-Air (OTA) Firmware Updates:

  • If the device is connected to the Internet, it will immediately search for possible updates. Updates are then requested cyclically every 12 hours.
  • Data transfer between the ELTAKO update server and the device meets the highest security standards.
  • Before an update is installed, it is checked whether it is correctly encrypted, validated and undamaged.
  • Updates are downloaded and installed, but only activated when no important process is running and no load is switched. The restart required for this takes a few seconds and goes unnoticed.
  • If an update fails or leads to device instability, the system automatically switches back to the previous firmware version and waits for a new update.

Offline firmware updates:
The device supports offline firmware updates via REST API. More information on this on the product website.

Technical data

  • Dimmable 230 V LED lamps
    Trailing edge up to 300 W 5) Leading edge up to 100 W 5)

  • Incandescent and halogen lamps 1) 230 V (R)
    up to 300 W

  • Inductive transformers (L)
    up to 300 W 2) 3)

  • Electronic transformers (C)
    up to 300 W 2) 3)

  • Dimmable energy saving lamps ESL
    up to 300 W 5)

  • Max./min. temperature at mounting location
    +50°C/-20°C 4)

  • Standby loss (active power)
    0.7 W

  1. Applies to lamps of max. 150 W.
  2. Per dimmer it is only allowed to use max. 2 inductive (wound) transformers of the same type, further-more no-load operation on the secondary part is not permitted. The dimmer might be destroyed. Therefore do not permit load breaking on the secondary part. Operation in parallel of inductive (wound) and capacative (electronic) transformers is not permitted!
  3. When calculating the load a loss of 20% for inductive (wound) transformers and a loss of 5% for capacitive (electronic) transformers must be considered in addition to the lamp load.
  4. Affects the max. switching capacity.
  5. Usually applies for dimmable energy saving lamps and dimmable 230 V LED lamps. Due to differences in the lamps electronics, there may be limited dimming range, switch on and off problems dependent on the manufacturer and a restriction on the maximum number of lamps; especially if the connected load is very low (for 5 W-LEDs).

Manuals and documents in further languages

https://eltako.com/redirect/EUD62NPN-IPM*110-240V

Eltako-EUD62NPN-IPM-110-240V-Universal-dimming-actuator-
fig-4

WIFI

  • Frequency
    2.4 GHz

  • Transmit power
    max. 100 mW

Hereby, ELTAKO GmbH declares that the radio equipment type EUD62NPN- IPM/110-240V is in com pliance with Directive 2014/53/EU. The full text of the EU declaration of con-formity can be accessed via the QR code or the internet address under ‘Documents’.

Must be kept for later use!

ELTAKO GmbH
D-70736 Fellbach Technical Support English:

+49 711 943 500 25
technical-support@eltako.de