Eltako GZD-BH98 Housing For False Ceiling Mounting Instructions

June 1, 2024
Eltako

Eltako GZD-BH98 Housing For False Ceiling Mounting

Eltako-GZD-BH98-Housing-For-False-Ceiling-Mounting-
Product

Product Information

Specifications:

  • Product Name: Housing for false ceiling mounting GZD-BH98
  • Compatible with DL2-BH98B-pm and DL2-BH98S-pm sensors
  • Hole Cutout: 72 mm
  • Installation Depth: 30 mm
  • Protection Class: IP20

Product Usage Instructions

Installation Process:

  1. Ensure the power is turned off before starting the installation process.
  2. Identify the location in the false ceiling where you want to mount the housing.
  3. Use a suitable tool to create a hole cutout of 72 mm in diameter.
  4. Insert the housing into the hole ensuring a secure fit.
  5. Make sure the installation depth is at least 30 mm to accommodate the housing properly.
  6. Connect the DL2-BH98B-pm or DL2-BH98S-pm sensor to the housing following the sensor’s installation instructions.
  7. Once everything is securely in place, restore power and test the system.

Maintenance:
Regularly check the housing for any signs of damage or wear and tear. Clean the housing as needed to maintain its appearance and functionality.

Safety Precautions:
Always follow safety guidelines when working with electrical components. If you are unsure about any part of the installation process, consult a professional electrician.

Frequently Asked Questions (FAQ):

  • Q: What is the IP20 protection class?
    A: The IP20 protection class indicates that the housing provides protection against solid objects larger than 12 mm and does not offer protection against water ingress.

  • Q: Can I use this housing with other sensors?
    A: This housing is specifically designed for use with DL2-BH98B-pm and DL2 -BH98S-pm sensors. It is recommended to use compatible sensors for optimal performance.

Housing for false ceiling mounting GZD-BH98
Housing for false ceiling mounting of the DL2-BH98B-pm and DL2-BH98S-pm sensors. Hole cutout 72 mm. Installation depth 30 mm. Protection class IP20.

Dimension

Eltako-GZD-BH98-Housing-For-False-Ceiling-Mounting-Fig-
\(1\)

Connecting Device

Eltako-GZD-BH98-Housing-For-False-Ceiling-Mounting-Fig-
\(2\)

Further Information

Manuals and documents in further languages:

Eltako-GZD-BH98-Housing-For-False-Ceiling-Mounting-Fig-
\(3\)

https://eltako.com/redirect/GZD-BH98

Contact Information

Must be kept for later use!

ELTAKO GmbH
D-70736 Fellbach

Technical Support English:

20/2024 Subject to change without notice.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals