Only skilled electricians may install this electrical equipment otherwise there is the risk of fire or electric shock!
Temperature at mounting location:
-20°C up to +50°C.
Storage temperature: -25°C up to +70°C.
Relative humidity: annual average value <75%.
ELTAKO Connect App download:
https://eltako.com/redirect/eltako-connect
Universal dimmer switch with integrated timer, Bluetooth and ELTAKO
Connect app. Power MOSFET up to 300 W. Automatic lamp detection.
Standby loss 0,3 watt only. Minimum brightness, maximum bright ness,
dimming speed, switching operation for children‘s rooms, snooze
function,
motion detector, ON, OFF, TI, ER, ESV, TLZ, MIN, MMX, Programs with
time or astro function, time offset solstice, date and time, location
and Bluetooth can be set via the app.
Modular device for DIN EN 60715 TH35 rail mounting. 1 module = 18 mm wide, 58
mm deep.
Universal dimmer switch for lamps up to 300 W, depending on ventilation
conditions, dimmable 230 V LED lamps and dimmable energy saving lamps (ESL)
are also dependent on the lamp electronics and the and the dimming technology.
Switching with soft start and soft OFF to protect lamps.
Control, supply and switching voltage 230 V.
The integrated timer has up to 10 program memory locations. With date and
automatic
summer time/winter time changeover.
Power reserve without battery approx. 5 days.
Each memory location can be used either with the Astro function (automatic
switching after sunrise or sunset), or one of the 9 functions (On, Off, On
with dimming value in %, On with memory value, light alarm clock, snooze
switch, On with residual brightness, Off with residual brightness, TI).
In case of a power failure the switching position and the brightness level are
stored and is switched on if necessary when the supply voltage returns.
Automatic electronic overload protection and over-temperature switch-off.
By briefly pressing the button on the front, you can always switch it on and
off manually.
The control input A1 is used to control pulses using a universal button. A
direction button for ‘off’ can be connected via the diode RTD (any polarity).
Another direction button for ‘on’ is connected directly to A1. With the first
control pulse ‘off’, the dimmer switch switches control input A1 to ‘direction
button’. In order to switch control input A1 back to ‘universal button’, the
supply voltage must be briefly switched off or switched in the app under basic
settings.
A motion detector can be connected via the BM control input. The additional
control inputs ZE and ZA are used to control centrally on and off with
priority. With priority because these control inputs cannot be overridden by
other control inputs as long as the central control contact is closed. The
green LED lighting up signals the activation of one of the four control
inputs.
The dimmer switch is set via the ELTAKO
Connect app.
Connect the timer to the app:
Press the button on the front for 6 seconds, the blue LED flashes. The
connection can now be established with the app (delivery status PIN123123
). The flashing of the blue LED signals that the pairing is ready. This ends
automatically after 3 minutes, but can also be ended manually by pressing a
button for >6 seconds. Scan the QR code on the operating instructions, the app
will guide you through the learning process. After the connection
to the app has been established, the blue LED lights up permanently. If the
connection is not disconnected via the app, it will auto matically disconnect
after 20 minutes of no interaction with the app.
After disconnecting the connection via the app, the dimmer switch signals its
readiness for pairing again and the blue LED flashes.
Bluetooth reset (delete any changed PIN): Briefly tap the button on the front
8 times.
Operation via the ELTAKO Connect app:
Basic settings:
Local pushbutton input (A1)
Auto (delivery status): Automatic detection of universal pushbutton /
direction push- button (with direction pushbutton diode RTD)
Directional pushbutton: Manual switching to direction pushbutton (with
direction pushbutton diode).
Universal pushbutton: Manual switching to universal pushbutton.
Operating mode
Auto (delivery status): Short control commands at the local control input
switch on/off, permanent control changes the brightness up to the maximum
value. An interruption in the control changes the dimming direction.
The central control has priority. The motion detector, light alarm clock and
snooze switch are active and can be configured.
Motion detector
No residual brightness: No residual brightness when the control input BM is no
longer activated and the off delay time (if set) has expired.
With residual brightness: With adjustable residual brightness when the control
input
BM is no longer activated and the off delay time (if set) has expired.
Residual brightness via switching program:
Same as ‘With residual brightness’, but in this setting you can also switch
‘edit’ with
residual brightness on and off under programs.
Residual brightness via ZE and ZA: Same as ‘No residual brightness’, in
addition ZE switches on with the set residual brightness and ZA switches off.
No residual brightness (semi-automatic):
The motion detector only switches off as soon as the control input BM is no
longer activated and the off delay time (if set) has expired.
Light alarm clock
Programs: The light alarm clock can only be switched on via a switching
program. When switching on (with the motion detector set to OFF), it switches
on after approx. 1 second with the lowest brightness and slowly dims up
without changing the last saved brightness level. The duration of the running
time can be set from 1 to 240 minutes in 1-minute increments.
Program and ZE: Same as ‘Programs’, but the light alarm clock can also be
switched on by briefly clicking on ZE.
Program and UT/RT: Same as ‘Programs’, but the light alarm clock can also be
started by double-clicking the universal button/direction button ‘on’.
Snooze function
Programs: Switch on the snooze switch only via a switching program. When
switching off (with the motion detector set to OFF), the lighting is dimmed
from the current dimming setting to the minimum brightness and switched off.
You can switch it off at any time during the dimming process by briefly
pressing the button. A long press during the dimming process dims up and ends
the snooze switch. The running time
can be set from 1 to 240 minutes in 1-minute increments.
About program and ZA: Like ‘Programs’, in addition the snooze switch can be
switched on by briefly clicking on ZA.
Program and UT/RT Off: Same as ‘Programs’, in addition the snooze switch can
be started by double-clicking the universal button/direction button ‘off’.
On : Permanent ON. Switching programs without function.
Off : Permanent OFF. Switching programs without function.
TI | Impulse generator starting with pulse:
Clock generator with adjustable switch-on and switch-off time from 0.1 seconds
to 9.9 minutes. The maximum brightness can be adjusted from 4 to 100%. Both
central inputs and BM have no function.
Relay function (ER): switching relay, the brightness can be adjusted from
4 to 100%.
The duration for soft on/off can be set under ‘Dimming behavior’. Both central
inputs, BM and switching programs without function.
ESV | Impulse switch with off delay:
Universal dimmer switch with adjustable off
delay from 1 to 120 minutes in 0.5 minute
increments. Switch-off warning at the end
can be selected by dimming down and can be
set from 0 to 3 minutes in 1-minute increments.
Both central inputs active. BM and switching
programs without function.
Staircase timer switch (TLZ): Staircase timer switch with switchable
switch-off warning by dimming down. Off delay adjustable from 1 to 120 minutes
in 0.5 minute increments. Within the first second after switching on or after
switching on, the off delay time can be extended by briefly pressing the
button up to 3 times (pumping). Each key adds the set time once. Switch-off
warning at the end can be selected by dimming down and can be set from 0 to 3
minutes in 1-minute increments. Activation of the button permanent light by
pressing a button on the local control input for longer than 1 second (1x
flickering), deactivation by pressing a button on the local control input for
longer than 2 seconds. The button continuous light can be set from 0 to 10
hours in 0.5 hour increments. The control inputs ZE and BM are used with short
commands to switch on and start the off-delay time. If the control is
continuous, the off-delay time is stopped.
You can always switch off via ZA.
MIN : Universal dimmer switch, switches to the set minimum brightness
when the control voltage is applied. During the set dimming time of 1 to 120
minutes, dimming occurs to maximum brightness. When the control voltage is
removed, the system switches off immediately, even during the dimming time.
Both central inputs active. BM and switching programs without function.
MMX : Function and parameters like ‘MIN’, but when the control voltage is
removed, it dims down to the set minimum brightness.
It then switches off.
Dimming behavior
Minimum brightness: Setting the minimum brightness from 4 to 90%. The
minimum brightness must always be 10% lower than the set maximum brightness.
Maximum brightness: Setting the maximum brightness from 14 to 100%. The
maximum brightness must always be 10% higher than the set minimum brightness.
Send brightness: Dim to the minimum/maximum brightness currently set in the
app without changing the memory value.
When dimming, the currently set dimming speed in the app is taken.
Dimming curves
Auto (delivery status): Allows dimming of all types of lamps. Inductive
(wound) transformers may only be used in this position! Leading edge: LC1-LC3
are comfort positions with different dimming curves for dimmable 230 V LED
lamps, which cannot be dimmed far enough on auto due to their design and
therefore have to be forced to leading edge.
Trailing edge: LC4-LC6 are comfort positions with different dimming curves for
dimmable 230 V LED lamps, which cannot be dimmed far enough on Auto.
Dimming speed: Setting the dimming speed.
Switch-on speed: Setting the switch-on speed.
Switch-off speed: Setting the switch-off speed.
Switch-on behavior
Use memory value: The memory value corresponds to the last dimming value
set. If the memory value is deactivated, dimming always occurs to the
adjustable switch-on value.
Switch-on brightness (only with activated memory value): Some lamps require an operating brightness to switch on. It is dimmed to the switch-on value and then dimmed to the memory value within the switch-on time. The switch-on time can be set from 0.1 to 5.0 seconds in 0.1 second increments.
Switch-on value: Setting the switch-on value.
Programs
Edit programs : Overview of all 10 programs.
By tapping the button, programs are visibly activated and deactivated. By
tapping on a
program, it can be configured.
Program active: Activate or deactivate the program.
Channel settings
On: Turns on the dimmer switch at the set switch-on speed. The ‘Auto’
operating mode must be activated for this.
Off: Turns off the dimmer switch at the set turn-off speed. The operating mode
‘Auto’ or ‘TI | Clock generator starting with pulse must be activated for
this.
On with dimming value in %: Switches on the dimmer switch with the set dimming
value and the set switch-on speed. The ‘Auto’ operating mode must be activated
for this.
On with memory value: Switches on the dimmer switch with the last saved memory value and the set switch-on speed. The ‘Auto’ operating mode must be activated for this.
Light alarm clock: Starts the light alarm clock with the set parameters. The
‘Auto’ operating mode must be activated for this.
Snooze: Starts the snooze with the set para- meters. The ‘Auto’ operating mode
must be activated for this.
On with residual brightness (BM): Switches on the dimmer switch with the set
residual brightness. The ‘Auto’ operating mode and the BM mode ‘Residual
brightness via switching program’ or ‘Residual brightness via ZE and ZA’ must
be activated for this.
Off with residual brightness (BM): Dims the dimmer switch to the set residual
brightness.
The ‘Auto’ operating mode and the BM mode ‘Residual brightness via switching
program’ or
‘Residual brightness via ZE and ZA’ must be activated for this.
TI | Impulse generator starting with pulse: Starts the impulse generator with
the set parameters.
The operating mode ‘TI | Impulse generator starting with pulse must be
activated for this.
Active days: Selection of the days of the week on which the switching program should switch. At least one day of the week must be selected per program.
Trigger
Time: Setting the time at which the switching program should switch.
Random mode: When random mode is switched on, all switching times are randomly
shifted by up to 15 minutes. Switch-on times to earlier and switch-off times
to later.
Astro: Activates automatic switching with sunrise or sunset. The switch-
on or switch-off time can be delayed by up to ± 2 hours. In addition, a time
difference of up to ± 2 hours influenced by the solstices can be entered.
For the astro function, the correct location must be set under ‘Location’. You
can find a list of German cities at the end of the operating instructions.
Time offset solstice: Setting the time offset during summer and winter
time. The time indicates the time offset from sunset. The sunrise is inverted
accordingly.
Adjustable from -2 hours to 2 hours in 10 minute increments.
Device
Device PIN: Manual or automatic setting of the date, time, time zone and
summer/winter
time possible.
Location : Manual or automatic entry of the
location possible.
Device PIN: Changing the device PIN (delivery status 123123) is possible.
Bluetooth: Activation of permanent visibility possible. By activating
permanent visibility, Bluetooth remains active on the dimmer switch and does
not need to be activated manually before establishing the connection.
Factory settings: Choose between deleting all programs, resetting the
dimming settings, resetting the Bluetooth settings and resetting to factory
settings.
longitude (LON) and latitude (LAT) in Germany time zone (GMT): +1, summer time: +2
more places on www.maps.google.de
Typical connection universal pushbutton UT
Typical connection directional pushbutton RT
Technical data
-
For lamps with a maximum of 150 W.
-
Per dimmer it is only allowed to use max. 2 inductive (wound) transformers of the same type, furthermore
no-load operation on the secondary part is not permitted. Possibly the dimmer switch will be destroyed!
No load-switching-off on the secondary part is allowed. The parallel operation of inductive (wound) and
capacitive (electronic) transformers is not allowed! -
When calculating the load 20% loss has to be considered for inductive (wound) transformers and
5% loss in addition to the lamp load. -
Affects the maximum switching power.
-
Usually applies for dimmable energy saving lamps and dimmable 230 V LEDs. Due to differences in the lamps electronics, there may be limited dimming range, switch on and off problems dependent on the manufacturer and a restriction on the maximum number of lamps; especially if the connected load is very low (for 5 W-LEDs). The comfort positions of leading edge and trailing edge optimise the dimming range, but this only results in a maximum output of up to 100 W. In these comfort settings no inductive (wound) transformers should be dimmed.
-
With a load of more than 100 W, a ventilation distance of ½ module to adjacent devices must be maintained.
The strain relief clamps of the terminals must be closed, that means the screws must be tightened for testing the function of the device. The terminals are open ex factory.
Manuals and documents in further languages:
http://eltako.com/redirect/EUD12NPN-BT*300W-230V
Hereby, ELTAKO GmbH declares that the radio equipment type EUD12NPN-BT/300W-
230V is in com pliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity can be accessed via the QR
code or the internet address under ‘Documents’.
Must be kept for later use!
ELTAKO GmbH
D-70736 Fellbach
Technical Support English:
+49 711 943 500 25
48/2023 Subject to change without notice.