3onedata IES2300SL Series Unmanaged Industrial Ethernet Switch Installation Guide

June 1, 2024
3onedata

3onedata IES2300SL Series Unmanaged Industrial Ethernet Switch Installation Guide
3onedata IES2300SL Series Unmanaged Industrial Ethernet
Switch

Package Checklist

Please check the integrity of package and accessories while first using the switch.

  1. Industrial Ethernet
  2. DIN-Rail mounting switch attachment
  3. Certification
  4. Warranty card
    If any of these items are damaged or lost, please contact our company or dealers, we will solve it ASAP.

Product Overview

This series of product is Gigabit unman aged DIN-Rail industrial Ethernet switch. For convenience, the products of this series adopt the following number on the left in this guide, please affirm the number of your product.

Model I. IES2300SL-5GT-2LV (5 Gigabit copper ports, 12/24/48VDC redundant power supply input).
Product Overview

Model II. IES2300SL-8GT-2LV (8 Gigabit copper ports (two-row RJ45), 12/24/48VDC redundant power supply)
Product Overview
Model III. IES2301SL-8GT-2LV (8 Gigabit copper ports (single-row RJ45), 12/24/48VDC redundant power supply)
Product Overview
Model IV. IES2300SL-16GT-2LV (16 Gigabit copper ports, 12/24/48VDC redundant power supply input).

Panel Design

Top view, bottom view and rear view

Front view

Front view

Model I Model II Model III Model IV

  1. Terminal blocks for power input (P1-P2)
  2. DIP switch
  3. Grounding screw
  4. DIN-Rail mounting kit
  5. Location hole for wall-mounting panel
  6. Ethernet port indicator (G1-G5/G8/G16)
  7. Running indicator (RUN)
  8. Power supply indicator (P1-P2)
  9. 10/100/1000Base-T(X) Gigabit (G1-G5/G8/G16)

Mounting Dimension

**Model I
Mounting Dimension
Model II
Mounting Dimension
Model III, Model IV

**

Notice Before Mounting:

  • Don’t place or install the device in area near water or moist, keep the relative humidity of the device surrounding between 5%~95% without
  • condensation. Before power on, first confirm the supported power supply specification to avoid over-voltage damaging the device.
  • The device surface temperature is high after running; please don’t directly contact to avoid scalding

DIN-Rail Mounting

The product adopts 35mm standard DIN-Rail mounting which is suitable for most industrial scenes, mounting steps as follows:
Mounting Dimension

Step 1 Check if the DIN-Rail mounting kit is installed firmly.
Step 2 Insert the bottom of DIN-Rail mounting kit (one side with spring support) into DIN-Rail, and then insert the top into DIN-Rail.
Tips: Insert a little to the bottom, lift upward and then insert to the top.
Step 3 Check and confirm the product is firmly installed on DIN-Rail, then mounting ends.

Disassembling DIN-Rail

Step 1 Power off the device.
Step 2 After lifting the device upward slightly, first shift out the top of DIN-Rail mounting kit, and then shift out the bottom of DIN-Rail, disassembling ends.

Notice before power on:

  • Power ON operation: First insert the power supply terminal block into the device power supply interface, then plug the power supply plug contact and power on.
  • Power OFF operation: First, remove the power plug, then remove the wiring section of terminal block. Please pay attention to the above operation sequence.

Power Supply Connection

Support 2 power inputs, and adopt 4-pin 5.08mm pitch terminal blocks. The power input supports 1 power supply alone or 2 power supply at the same time; When two power supply input at the same time, it supports redundant backup of power supply. If one power supply fails, the device can still work normally without interruption. Power supply supports anti-reverse connection, which cannot power the device but won’t damage it when it’s reversely connected. The definitions of power pin are shown in the figure above, and the power input range is 12/24/48 VDC (49~60VDC).

DIP Switch Settings

This series provide 4-pin DIP switch for function setting, where “ON” is the enabled end. The definitions of DIP switch are as follows:

Model I

No. Definition Operation
1 Forced 100M be forced to be Set the switch to ON, Port 1-5 would in 100M
2 Storm Set the Suppression su switch to ON to enable storm oppression

function
3| VLAN| Set the DIP switch to ON, Port 1 linkup port, Port 2-5 are the down link
No.| Definition| Operation
| | ports, and the down link ports are isolated from each other.
4| Flow control| Set the switch to ON to enable flow control function.

Model II Model III

ON Definition Operation
1 Forced Set th be forced to b e switch to ON, Port 1-8 would 100M e in 100M
2 Storm Set the Suppression switch to ON to enable storm suppression

function
3| Davenports, and the isolated from| Set the DIP switch to ON, Port 1 is up link port, Port 2-8 are the down link down link ports are each other.
4| Set the switch Flow control control function| h to ON to enable flown.

Model IV

No. Definition Operation
1 Loop Set the Detection loo switch to ON to enable port p detection

function.
2| Storm Set the Suppression| switch to ON to enable storm suppression function.
3| Set the DIP sear up link pro VLAN are isolated fr| witch to ON, Port 1- 2 ts, Port 3-16 are the down link ports, and the down link ports om each other.
4| Set the switch Flow control control function| h to ON to enable flow on.

Checking LED Indicator **

**

The device provides LED indicators to monitor its operating status, which has simplified the overall troubleshooting process. The function of each LED is described in the table below:

LED Indicate Description
P1-P2 ON Power   is   connected and running normally
OFF Power supply is disconnected or running abnormally The device is powering

on or
RUN| ON| the device is abnormal.The device is running
Blinking| normallyThe device is powered off or
OFF| the device is abnormal.Ethernet port has established
G1-G5/G8/G16| ON| a valid network connectionEthernet port is in an active network status
Blinking| Ethernet port has not established a valid network
OFF| connection

Specification

Pan|
---|---
| 00 Base-T(X) self- adapting RJ45 port, half/full duplex self-adaption or forced working mode, support MDI/ MDI-X self-adaption
Indicator| Power     indicator,      running indicator, interface indicator
Switch Property|
Model I| Back plane bandwidth: buffer size: 2Mbit MAC address table: 2K
Model II Model III| Back plane bandwidth: 16G Buffer size: 1.5Mbit MAC address table: 4K
Model IV| Back plane bandwidth: 52G Buffer size: 4.1Mbit MAC address table: 8K
Power supply|
Input power supply| 12/24/48 VDC(9~60VDC), dual power supply redundancy, support anti-reverse connection
---|---
Access terminal block| 4-pin 5.08mm pitch terminal blocks
Power Consumption|
Model I| No-load: 0.2W@12VDC
Full-load: 1.6W@12VDC
Model II, Model
III Model IV| No-load: 0.4W@12VDCFull-load: 3.0W@12VDC
| No-load: 3.3W@48VDCFull-load: 10.4W@48VDC
Working Environment|
Working temperature| -40~75
Storage temperature| ℃ -40~85
Working humidity| ℃ 5%〜95% (no condensation)
Protection grade| IP40 (metal shell)

Disposal of Waste Electrical and Electronic Equipment (WEEE 2012/19/EU)

Applicable in the EU-member states)
The crossed-out wheeled bin symbol on the equipment or its packaging indicates that the product, at the end of its service life, shall not be mixed with unsorted municipal waste but should be collected separately, in accordance with local laws and regulations
A proper separate collection of end-of-life equipment for the subsequent recycling, treatment and environmentally compatible disposal, will help prevent potential damage to the environment and human health, facilitating the reuse, recycling and/or recovery of its component materials.
Private users should contact their vendor or municipal waste management service and ask for disposal information.

Professional users should contact their suppliers and check the terms of their selling agreement.
This product must not be disposed of with other commercial waste.
Users’ cooperation in the correct disposal of this product will contribute to saving valuable resources and protecting the environment.

Bonedata Co., Ltd.
Address: 3/B, Zone 1, Baiwangxin High Technology Industrial Park, Xili, Nanshan District, Shenzhen
Website: www.3onedata.com
Tel: +86 0755-26702688
Fax: +86 0755-26703485
Company logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

3onedata User Manuals

Related Manuals