**3onedata IES2210 Series Unmanaged Industrial Ethernet Installation Guide

**

Installation Instruction

【Package Checklist

Please check whether the package and accessories are intact while using the switch for the first time.

  1. Industrial Ethernet switch 2. Certification
  2. DIN-Rail mounting attachment 4. Warranty card

If any of these items are damaged or lost, please contact our company or dealers, we will solve it ASAP

【Product Overview

This series are unmanaged DIN-Rail industrial Ethernet switches. Models as follows:
Model I. IES2210-8T2GC-2P48 (8 100M copper ports + 2 Gigabit Combo ports + 2 48VDC power supplies)

Model II. IES2210-8T2GC-P220 (8 100M copper ports +2
Gigabit Combo ports +1 220VAC power supply)
Model III. IES2210-4T2GC-2P48 (4 100M copper ports + 2
Gigabit Combo ports + 2 48VDC power supplies)
Model IV. IES2210-4T2GC-P220 (4 100M copper ports + 2
Gigabit Combo ports + 1 220VAC power supply)
Model V. IES2210-8P2GC-2P24-120W (8 100M POE
copper ports +2 Gigabit Combo ports +2 24VDC
power supplies +120W POE power)
Model VI. IES2210-8P2GC-2P48-120W (8 100M POE
copper ports +2 Gigabit Combo ports +2 48VDC
power supplies +120W POE power)
Model VII. IES2210-8P2GC-2P48-240W (8 100M POE
copper ports + 2 Gigabit Combo ports + 2 48VDC
power supplies +240W POE power)
Model VIII. IES2210-4P2GC-2P24-60W (4 100M POE copper
ports +2 Gigabit Combo ports +2 24VDC power
supplies + 60W POE power)
Model IX. IES2210-4P2GC-2P24-120W (4 100M POE
copper ports + 2 Gigabit Combo ports +2 24VDC
power supplies + 120W POE power)
Model X. IES2210-4P2GC-2P48-120W (4 100M POE
copper ports +2 Gigabit Combo ports +2 48VDC
power supplies + 120W POE power)

【AC Panel Design

Top view, Bottom view and Rear view

  1. AC power input terminal block
  2. Relay alarm output terminal block
  3. DIP switch
  4. Console port
  5. Grounding screw
  6. Wall-mounted location hole
  7. DIN-Rail mounting kit
  8. Device running indicator RUN
  9. Relay alarm indicator ALM
  10. Power input status indicator PWR
  11. 100M copper port
  12. Ethernet port indicator
  13. Combo port

【DC Panel Design】

Top view, Bottom view and Rear view

  1. power input terminal block
  2. Relay alarm output terminal block
  3. DIP switch
  4. Console port
  5. Grounding screw
  6. Wall-mounted location hole
  7. DIN-Rail mounting kit
  8. Device running indicator RUN
  9. Relay alarm indicator ALM
  10. Power input status indicator PWR
  11. 100M copper port
  12. Ethernet port indicator
  13. Combo port
  14. POE indicator

【Mounting Dimension

Unit: mm

Attention before mounting:

  • **** Don’t place or install the device in area near water or moist, keep the relative humidity of the device surrounding between 5%~95% without condensation.
  • Before power on, first confirm the supported power supply specification to avoid over-voltage damaging the device.
  • The device surface temperature is high after running; please don’t directly contact to avoid scalding.

【DIN-Rail Mounting】
The product adopts 35mm standard DIN-Rail mounting, which is suitable for most of the industrial scenes. Mounting steps as below:

Step 1 Check if the DIN-Rail mounting kit is installed firmly.
Step 2 Insert the bottom of DIN-Rail mounting kit (one side with spring support) into DIN-Rail, and then insert the top into DIN-Rail.
Tips:
Insert a little to the bottom, lift upward and then insert to the top.
Step 3 Check and confirm the product is firmly installed on DIN-Rail, then mounting ends.

【Disassembling DIN-Rail】

Step 1 Power off the device.
Step 2 After lift the device upward slightly, first shift out the top of DIN-Rail mounting kit, then shift out

Attention before power on :

  • Power ON operation:
  • first connect power line to the connection terminal of device power supply, then power on. Power OFF operation: first unpin the power plug, then remove the power line, please note the operation order above.

【Power Supply Connection】
DC power supply 24VDC

This series of model V, model VIII, model IX provide 6 pins 5.08mm pitch input terminal blocks, including 4 pins power supply terminal blocks on the left side. It provides two independent DC power supply systems of P1 and P2. The power supply is anti-reverse connection.

Power input voltage: 24VDC

DC power supply 48VDC

This series of model I, model III, model VI model VII and model X provide 6 pins 5.08mm pitch input terminal blocks, including 4 pins power supply terminal blocks on the left side. It provides two independent DC power supply systems of P1 and P2. The power supply is anti-reverse connection.

Power input voltage of model VI model VII and model X:
48VDC, power input voltage of model I and model III: 48VDC (12~48VDC).

AC power supply 220VAC
This series of model II and model IV

support AC single power supply and provide 6 pins 5.08mm pitch input
terminal blocks, including 4 pins power supply terminal blocks on the left side.
Power input voltage: 220VAC (85~264VAC

**【PoE Power Supply Pin Connection 】

**

(Relay Connection】
The device provides 6-pin 5.08mm pitch input terminal blocks, including 2-pin relay terminal blocks on the right side. Relay terminals are a pair of normally open contacts in device alarm relay. They are open circuit in normal non alarm state, closed when any alarm information occurs. For example: it’s closed and sends out alarm when power off. The switch supports 1 relay alarm information and network abnormal alarm output, it can be connected to alerting lamp, alarm buzzer, or other switching value collecting devices for timely warning operating staffs when alarm information occurs.

【DIP Switch Settings】

This series provide 4 pins DIP switch for function settings, where “ON” is enable valid terminal. DIP switch definition as follows:

DIP Definition Operation
1 Flow control Set the DIP switch to ON, and the device will enable flow

control
2| Port with the specified speed of 10M| Set the DIP switch to ON, andthe 100M copper port of the device will be specified as 10M
DIP| Definition| Operation
---|---|---
| | copper port
3| Alarm| Set the DIP switch to ON, andthe device will enable port alarm
4| Reserved| –

【Specification】

LED Status Description

P1/P2/PWR

| ON| Power supply is connected and running normally
OFF| Power supply is disconnected and running abnormally.
ALM| ON| Port link alarm
OFF| Port link without alarm

RUN

| ON| The device is powered on orthe device is abnormal.
OFF| The device is powered off orthe device is abnormal.
Blinking| System is running well.
Link/ACT(1-4/8, G1-G2)| ON| Ethernet port connection isactive.
Blinking| Data transmitted
OFF| Ethernet port connection isinactive.POE port supply electricity
POE (1-4/8)| ON| for other devices normally POE is disabled or
OFF| disconnected

【Checking LED Indicator 】

POE pins V+, V+, V-, V- arecorresponding to 1, 2, 3, 6.
Gigabit Combo port 10/100/1000Base-T(X) or 1000Base-X
Console port Reserved

Alarm interface

| 6-pin 5.08mm pitch terminal blocks, including 2-pin alarm terminal blocks. It supports 1 relay alarm information output, current load capacity is 1A@30VDC or 0.3A@125VAC
Indicator| Run indicator, interfaceindicator power indicator, alarm indicator, PoE indicator
Exchange attributes|
Backplane bandwidth| 7.6G
Packet buffer size| 1Mbit
MAC table size| 8K
Power supply|

Input power supply

| Power supply input voltage: 48VDC, 24VDC, 220VACSupport DC dual power supply redundancy, anti-reverseconnection
Access terminal| 6-pin 5.08mm pitch terminalblocks, including 4-pin power supply terminal blocks
Consumption|
No-load| ≤4.9W@48VDC
Full-load| ≤122.8W@48VDC
Environmental limits|
Working temperature| -40~75℃
Storage temperature| -40~85℃
Working humidity| 5%~95% (no condensation)
Protection grade| IP40 (metal shell)

References