3onedata IES6000-4GT2HS Industrial Ethernet Switch Installation Guide

June 25, 2024
3onedata

3onedata IES6000-4GT2HS Industrial Ethernet Switch

Specifications

  • Model : IES6000-4GT2HS
  • Ports : 4 Gigabit Copper Ports + 2 2.5G SFP
  • Power Supply : 12~48VDC

Product Overview
The IES6000-4GT2HS is a Gigabit-managed DIN-Rail industrial Ethernet switch designed for industrial use.

Mounting Dimension

  • Unit : mm
  • Front View: Check the DIN-Rail mounting kit for proper installation. Insert the kit into the DIN-Rail securely.

DIN-Rail Mounting
The product uses a standard 35mm DIN-Rail mounting system suitable for most industrial environments. Follow these steps:

  1. Ensure the DIN-Rail mounting kit is securely installed.
  2. Insert the bottom of the kit into the DIN-Rail, then insert the top.
  3. Check the firm installation and secure the ends.

Disassembling DIN-Rail
Power off the device before disassembling it. Shift out the top and bottom of the DIN-Rail mounting kit to remove the switch.

Power Supply Connection
The device has 6-pin 5.08mm pitch input terminal blocks for power supply. It supports two independent DC power supply systems of P1 and P2 with a voltage range of 12~48VDC.

Relay Connection
This device provides 6-pin 5.08mm pitch input terminal blocks for relay connections. Refer to the user manual for detailed instructions on relay setup.

Package Checklist

Please check the integrity of package and accessories while first using the switch.

  1. Industrial Ethernet switch
  2. Certification
  3. Quick installation guide
  4. Warranty card
  5. DIN-Rail mounting attachment 6 CD

If any of these items are damaged or lost, please contact our company or dealers, we will solve it ASAP.

Product Overview

This product is Gigabit managed DIN-Rail industrial Ethernet switch.

The model is: IES6000-4GT2HS (4 Gigabit Copper Ports + 2 2.5G SFP)

Panel Design
Top view, bottom view and rear view

Front View

  1. DIN-Rail mounting kit
  2. Power input terminal (P1, P2)
  3. Relay alarm output terminal block
  4. DIP switch
  5. Console port
  6. Grounding screw
  7. Power input status indicator P1
  8. Relay alarm indicator ALM
  9. Device running indicator RUN
  10. Power input status indicator P2
  11. 2.5G SFP interface state indicator
  12. 2.5G SFP slot
  13. 10/100/1000Base-T(X) Gigabit Ethernet Interface
  14. Ethernet port link indicator

Mounting Dimension

Notice Before Mounting:
Don’t place or install the device in area near water or moist, keep the relative humidity of the device surrounding between 5% -95% without condensation. Before power on, first confirm the supported power supply specification to avoid over-voltage damaging the device. The device surface temperature is high after running; please don’t directly contact to avoid scalding.

DIN-Rail Mounting

The product adopts 35mm standard DIN-Rail mounting which is suitable for most industrial scenes, mounting steps as follows:

  1. Step 1 Check if the DIN-Rail mounting kit is installed firmly.

  2. Step 2 Insert the bottom of DIN-Rail mounting kit (one side with spring support) into DIN-Rail, and then insert the top into DIN-Rail.
    Tips: Insert a little to the bottom, lift upward and then insert to the top.

  3. Step 3 Check and confirm the product is firmly installed on DIN-Rail, then mounting ends.

Disassembling DIN-Rail

  1. Step 1 Power off device.
  2. Step 2 After lifting the device upward slightly, first shift out the top of DIN-Rail mounting kit, and then shift out the bottom of DIN-Rail, disassembling ends.

Notice before power on:

  • Power ON operation: First insert the power supply terminal block into the device power supply interface, and then plug the power supply plug contact and power on.
  • Power OFF operation: First, remove the power plug, and then remove the wiring section of terminal block. Please pay attention to the above operation sequence.

Power Supply Connection

This device provides 6-pin 5.08mm pitch input terminal blocks, including 4 pins power supply terminal blocks on the left side. It provides two independent DC power supply systems of P1 and P2. The power supply supports anti-reverse connection, which can prevent device from damage after it’s reversely connected, but it cannot be powered on.

Voltage range: 12-48VDC.

Relay Connection

This device provides 6-pin 5.08mm pitch input terminal blocks, and the relay occupies the right 2 pins. Relay terminals are a set of normally open contacts of the device alarm relay. They are open circuit in the state of normal non alarm, closed when any alarm information occurs. For example, they are closed when powered off, and send out alarm. The switch supports 1 relay alarm information output that can output DC power supply alarm information or network abnormality alarm. It can be connected to alarm light or alarm buzzer or other switching value collecting devices, which can timely inform operators when the alarm occurs.

DIP Switch Settings

Provide 4 pins DIP switch for function settings, where “ON” is enabled valid terminal. The device needs to be powered on again to change the status of the DIP switch.

DIP switches definition as follows:

DIP Definition Operation

1

|

Restore Factory Settings

| Set the DIP switch to ON, the device will root automatically and restore to factory settings, then turn off the DIP switch.
2| Reserved| –
3| Reserved| –
4| Reserved| –

The device provides LED indicators to monitor the device working status with a comprehensive simplified troubleshooting; the detailed status of each LED is described in the table as below

LED Indicate Description

P1

| ON| P1      is

normally

| connected| and| running
OFF| P1 is disconnected and running abnormally

P2

| ON| P2 is connected and running

normally

OFF| P2 is disconnected and running

abnormally

ALM| ON| Power supply link has alarm
OFF| Power supply link have no alarm

RUN

| ON| The device is powered on or the device is abnormal.
OFF| The device is powered off or the

device is abnormal.

Blinking| Blinking 1 time per second, the

device is running well.

Link/Act (1-6)

|

ON

| The Ethernet interface has

established a valid network connection.

Blinking| The Ethernet interface is in a

network activity state.

OFF

| The Ethernet port has not

established a valid network connection

Specification

Panel|
---|---
2.5G SFP slot| 100/1000 Base-X self-adaption or 100/1000/2.5G Base-X forced

mode, SFP slot

Gigabit copper port| 10/100/1000 Base-T(X) self-adapting RJ45 port, half/full duplex self-adaption or forced working mode, support MDI/ MDI-X self-adaption
---|---
Console port| CLI command management port (RS-232), RJ45
Alarm interface| 6-pin 5.08mm pitch terminal

blocks, alarm occupies 2 pins and 1 relay alarm information output is supported, the current load capability is 1A@30VDC or 0.3A@125VAC

Power supply indicator, run

Indicator| indicator, interface indicator, alarm indicator
Switch Property|
Backplane bandwidth| 30G
Packet buffer size| 4Mbit
MAC Address Table| 8K
Power Supply|
Input power supply| 12~48VDC

Support dual power supply redundancy,                 anti-reverse connection

Access terminal block| 6-pin 5.08mm pitch terminal blocks, power supply occupies 4 pins
Power Consumption|
No-load| 3.2W@24VDC 6.6W@24VDC
Full-load|
Working Environment| -40〜75℃
Working temperature| -40〜85℃
Storage temperature| 5%〜95% (no condensation)
Working humidity| IP40 (metal shell)
Protection grade|

Disposal of Waste Electrical and Electronic

Equipment (WEEE 2012/19/EU)): (Applicable in the EU-member states)

  • The crossed-out wheeled bin symbol on the equipment or its packaging indicates that the product, at the end of its service life, shall not be mixed with unsorted municipal waste but should be collected separately, in accordance with local land and regulation
  • A proper separate collection of end-of-life equipment for the subsequent recycling, treatment and environmentally compatible disposal, will help prevent potential damage to the environment and human health, facilitating the reuse, recycling and/or recovery of its component materials.
  • Private users should contact their vendor or municipal waste management service and ask for disposal information.
  • Professional users should contact their suppliers and check the terms of their selling agreement.
  • This product must not be disposed of with other commercial waste.
  • Users’ cooperation in the correct disposal of this product will contribute to saving valuable resources and protecting the environment.

FAQ

Q: What should I do if any items from the package checklist are damaged or lost?
A: If any items are damaged or lost, please contact our company or dealers for assistance in resolving the issue promptly.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

3onedata User Manuals

Related Manuals