3onedata IES2105-Series Unmanaged Industrial Ethernet Switch Installation Guide

June 2, 2024
3onedata

3onedata-logo

3onedata IES2105-Series Unmanaged Industrial Ethernet Switch

Specifications

  • Model: IES2105 Series Unmanaged Industrial Ethernet Switch
  • Speed: 100M
  • Power Supply: 12~48VDC
  • Mounting: DIN-Rail

Product Overview
The IES2105 Series is a range of 100M unmanaged industrial Ethernet switches. The products in this series are designed for industrial use and provide reliable network connectivity.

Panel Design
The switch features various indicators and ports including power supply indicator, copper ports, interface connection indicator, PoE indicator, PoE copper port, fiber port, DIN-Rail mounting kit, terminal block for power input, DIP switch, and grounding screw.

Mounting Dimension
The product adopts a standard 35mm DIN-Rail mounting suitable for most industrial environments.

Power Supply Connection
The switch requires a 12~48VDC power supply for operation. Follow the specified power supply connection instructions to avoid damaging the device.

DIP Switch Settings
The DIP switch on the device allows for function setting. Refer to the provided DIP switch settings guide for configuring features such as jumbo frame and flow control.

DIN-Rail Mounting

  1. Check if the DIN-Rail mounting kit is installed firmly.
  2. Insert the bottom of DIN-Rail mounting kit into DIN-Rail, then insert the top into DIN-Rail after lifting slightly.
  3. Confirm the product is firmly installed on DIN-Rail.

Disassembling DIN-Rail

  1. Power off the device.
  2. Lift the device upward slightly and shift out the top of DIN-Rail mounting kit, then shift out the bottom to disassemble.
  3. Ensure proper disassembly before maintenance or relocation.

Safety Guidelines

  • Avoid placing the device in areas near water or moisture.
  • Ensure relative humidity levels are between 5%~95% without condensation.
  • Follow correct power on/off operations to prevent damage to the device.
  • Avoid direct contact with the device surface after operation due to high temperature.

FAQ
Q: What should I do if any items in the package are damaged or lost?
A: If any items such as the switch, DIN-Rail mounting kit, certification, or warranty card are damaged or lost, please contact our company or authorized dealers for assistance.

1E52105 Series Unmanaged Industrial Ethernet Switch Quick

Installation Guide

3onedata-IES210--Series-Unmanaged -Industrial-Ethernet-Switch-
\(2\)

Address: 3/B, Zone 1, Baiwangxin High Technology  Industrial Park, Xili, Nanshan District, Shenzhen

(Package Checklist )
Please check whether the package and accessories are intact while using the switch for the first time.

  1. Switch (with termina
  2. DIN-Rail mounting block) attachment
  3. Certification
  4. Warranty card If any of these items are damaged or lost, please contact our company or dealers, we will solve it ASAP.

[Product Overview)

This series are 100M unmanaged industrial Ethernet switches. For convenience, the products of this series adopt the following number on the left in this guide, please affirm the number of your product.

  • Model I. IES2105-5T-P48 (5 100M copper ports + 1 48VDC power supply)
  • Model II. IES2105-5T-P220 (5 100M copper ports + 1 220VAC power supply)
  • Model III. IES2105-4P1T-P48 (4 100M PoE copper ports + 1 100M copper port + 1 48VDC power supply)
  • Model IV. IES2105-4P1F-P48 (4 100M PoE copper ports + 1 100M fiber port + 1 48VDC power supply)
  • Model V. IES2105-4T1F-P48 (4 100M copper ports + 1 100M fiber port + 1 48VDC power supply)
  • Model VI. IES2105-4T1F-P220 (4 100M copper ports + 1 100M fiber port + 1 220VAC power supply)
  • Model VII. IES2105-3T2F-P48 (3 100M copper ports + 2 100M fiber ports + 1 48VDC power supply)
  • Model VIII. IES2105-3T2F-P220 (3 100M copper ports + 2 100M fiber ports + 1 220VAC power supply)

Panel Design

3onedata-IES210--Series-Unmanaged -Industrial-Ethernet-Switch-
\(3\) Rear view, Bottom view and Top view

  1. 3onedata-IES210--Series-Unmanaged -Industrial-Ethernet-Switch- \(5\)Power supply indicator
  2. 100M copper port
  3. Interface connection
  4. indicator PoE indicator
  5. 100M PoE copper port
  6. 100M Fiber Port
  7. DIN-Rail mounting kit
  8. Terminal block for power
  9. input DIP switch
  10. Grounding screw

Mounting Dimension

Unit: mm

3onedata-IES210--Series-Unmanaged -Industrial-Ethernet-Switch-
\(6\) DIN-Rail Mounting

The product adopts 35mm standard DIN-Rail mounting which is suitable for most industrial scenes, mounting steps as follows:

  1. 3onedata-IES210-Series-Unmanaged -Industrial-Ethernet-Switch- \(7\)Step 1 Check if the DIN-Rail mounting kit is installed firmly.
  2. Step 2 Insert the bottom of DIN-Rail mounting kit (one side with spring support) into DIN-Rail, and then insert the top into DIN-Rail.
  3. Step 3 Tips: Insert a little to the bottom, lift upward and then insert to the top. Check and confirm the product is firmly installed on DIN-Rail, then mounting ends.

Disassembling DIN-Rail

  1. Step 1 Power off device.
  2. Step 2 After lifting the device upward slightly, first shift out the top of DIN-Rail mounting kit, and then shift out the bottom of DIN-Rail, disassembling ends.

Notes :

  • Don’t place or install the device in area near water or moist, keep the relative humidity of the device surrounding between 5%~95% without condensation.
  • Before power on, first confirm the supported power supply specification to avoid over-voltage damaging the device.
  • The device surface temperature is high after running; please don’t directly contact to avoid scalding.

Power Supply Connection

12~48VDC power supply

Model I, V, VII devices of this series support DC power input, and provide 3-pin terminals with a spacing of 7.62 mm. The power supply has non-polarity function. Voltage range:
12~48VDC. The pin definitions of power supply are shown as follows:

PIN 1 2 3
Definition V+ FG V-

48VDC power supply

Model III, IV devices of this series support DC power input, and provide 3-pin terminals with a spacing of 7.62 mm. The power supply has an anti-reverse connection function. Support
48V PoE, power range: 48VDC (44~55VDC). The pin definitions of power supply are shown as follows:

PIN 1 2 3
Definition V+ FG V-

AC power supply

Model II, VI, VIII devices of this series support AC power input, and provide 3-pin terminals with a spacing of 7.62 mm. Power supply range: 220VAC (100~240VAC). The
pin definitions of power supply are shown as follows:

PIN 1 2 3
Definition L FG N

Notice:

  • Power ON operation: First insert the power supply terminal block into the device power supply interface, and then plug the power supply plug contact and power on.
  • Power OFF operation: First, remove the power plug, and then remove the wiring section of terminal block. Please pay attention to the above operation sequence.

DIP Switch Settings

This series provide 4-pin DIP switch for function setting, where “ON” is the enabled end. DIP switches definition as follows:

DIP Definition Operation
1 Jumbo frame Set the DIP to ON to enable jumbo frame function
2 Flow Control Set the DIP to ON to enable flow

control function

3| One-key VLAN| Set the DIP to ON to enable VLAN function. Port 5 is interconnected with other interfaces, and other ports except port 5 are isolated from each other
4| Reserved| –

Checking LED Indicator

The device provides LED indicators to monitor the device working status with comprehensive simplified troubleshooting; the detailed status of each LED is described in the table as below:

LED Indicate Description

PWR

| ON| PWR is connected and running normally
OFF| PWR is disconnected and running abnormally
PoE(1-4)| ON| POE port is powering other devices normally
| OFF| POE is disabled or disconnected
---|---|---
Link/ACT (1-5)| ON| Port has established valid network

connection

Blinking| Port is receiving/ transmitting data
OFF| Port   hasn’t   established   valid

network connection

Specification

Panel|
---|---
100M Fiber Port| 100Base-FX, optional SC/ST/FC 10/100Base-T(X) self-adapting
100M copper port| RJ45 port, half/full duplex self- adaption or forced working mode, support MDI/ MDI-X self- adaption 10/100Base-T(X)      RJ45,
100M POE copper port| automatic flow control, full/half duplex mode, MDI/ MDI-X autotunning, POE port, output power of 15W or 30W.

V+, V+, V-, V- are corresponding to 1, 2, 3, 6.

POE pin| Power indicator, PoE indicator, interface indicator
Indicator|
Power Supply|
Input power supply|

  • 12~48VDC power supply, support non-polarity
  • 48VDC power supply: 44~55VDC, support anti-reverse connection D 220VAC power supply:

100~240VAC

Access terminal block| 3-pin 7.62mm pitch terminal blocks
Switch Property|
Backplane bandwidth| 1G
MAC address| 2K
Power Consumption|
---|---
Model I| No-load: ≤0.96W@48VDC Full-load: ≤1.4W@48VDC
Model IV| No-load: ≤2W@48VDC

Full-load:≤110W@48VDC (with PoE full load)

Working Environment|
Working temperature| -40〜75℃
Storage temperature| -40〜85℃
Working humidity| 5%〜95% (no condensation)
Protection grade| IP40 (metal shell)

【Disposal of Waste Electrical and Electronic Equipment (WEEE 2012/19/EU)】
(Applicable in the EU-member states)

The crossed-out wheeled bin symbol on the equipment or its packaging indicates that the product, at the end of its service life, shall not be mixed with unsorted municipal waste but should be collected separately, in accordance with A proper separate collection of end-of-life equipment for the subsequent recycling, treatment and environmentally compatible disposal, will help prevent potential damage to the environment and human health,facilitating the reuse, recycling and/or recovery of its component materials.
Private users should contact their vendor or municipal waste management service and ask for disposal information.
Professional users should contact their suppliers and check the terms of their selling agreement.
This product must not be disposed of with other commercial waste.

Users’ cooperation in the correct disposal of this product will contribute to saving valuable resources and protecting the environment.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

3onedata User Manuals

Related Manuals