3onedata IES6000-8GT2HS Industrial Ethernet Switch Installation Guide

June 26, 2024
3onedata

IES6000-8GT2HS
Layer 2 Managed
Industrial Ethernet Switch
Quick Installation Guide
3onedata IES6000-8GT2HS Industrial Ethernet Switch -
Cover
3onedata Co., Ltd.
Address:3/B, Zone 1, Baiwangxin High Technology
Industrial Park, Xili, Nanshan District,

Shenzhen
Website: www.3onedata.com
Tel: +86 0755-26702688
Fax: +86 0755-26703485

Package Checklist

Please check the integrity of package and accessories while first using the switch.

  1. Industrial Ethernet switch
  2. Quick Installation Guide
  3. CD
  4. DIN-Rail mounting attachment
  5. Warranty card
  6. Certificate

If any of these items are damaged or lost, please contact our company or dealers, we will solve it ASAP.

Product Overview

This product is layer 2 managed DIN-Rail industrial Ethernet switch. The model is: IES6000-8GT2HS (8 Gigabit Copper Ports + 2 2.5G SFP)

Panel Design

Top view, bottom view and rear view

3onedata IES6000-8GT2HS Industrial Ethernet Switch - Panel
Design

Front view and Side view

3onedata IES6000-8GT2HS Industrial Ethernet Switch - Panel Design
2

  1. Input terminal block for Power 1
  2. Input terminal block for Power 2
  3. Relay alarm output terminal block
  4. DIP switch
  5. Console port
  6. Grounding screw
  7. Wall-mounting location hole
  8. DIN-Rail mounting kit
  9. Power indicator (P1/P2)
  10. Alarm indicator (ALM)
  11. Running indicator (RUN)
  12. Interface connection indicator (G1-G10)
  13. 10/100/1000Base-T(X) copper port (G1-G8)
  14. 2.5G SFP slot (G9-G10)

Mounting Dimension

Unit: mm

3onedata IES6000-8GT2HS Industrial Ethernet Switch - Mounting
Dimension

Notice Before Mounting:

  • Don’t place or install the device in area near water or moist, keep the relative humidity of the device surrounding between 5%~95% without condensation.
  • Before power on, first confirm the supported power supply specification to avoid overvoltage damaging the device.
  • The device surface temperature is high after running; please don’t directly contact to avoid scalding.

DIN-Rail Mounting

The product adopts 35mm standard DIN-Rail mounting which is suitable for most industrial scenes, mounting steps as follows:

3onedata IES6000-8GT2HS Industrial Ethernet Switch - DIN-Rail
Mounting

Step 1: Check if the DIN-Rail mounting kit is installed firmly.
Step 2: Insert the bottom of DIN-Rail mounting kit (one side with spring support) into DIN-Rail, then insert the top into DIN-Rail.
Tips:
Insert a little to the bottom, lift upward and then insert to the top.
Step 3: Check and confirm the product is firmly installed on DIN-Rail, then mounting ends.

Disassembling DIN-Rail

Step 1: Power off device.
Step 2: After lifting the device upward slightly, first shift out the top of DIN-Rail mounting kit, and then shift out the bottom of DIN-Rail, disassembling ends.

Notice before power on:

  • Power ON operation: First insert the power supply terminal block into the device power supply interface, and then plug the power supply plug contact and power on.
  • Power OFF operation: First, remove the power plug, and then remove the wiring section of terminal block. Please pay attention to the above operation sequence.

Power Supply Connection

The device provides 6-pin 5.08mm pitch power supply terminal blocks. It supports two independent DC power supply systems, P1 and P2. Power supply supports non-polarity and  redundant backup. The definitions of power pin are shown in the left figure, and the power supply input is 12~48VDC.

Relay Connection

This device provides 6-pin 5.08mm pitch input terminal blocks, and the relay occupies the right 2 pins. Relay terminals are a set of normally open contacts of the device alarm relay. They are open circuit in the state of normal non alarm, closed when any alarm information occurs. For example, they are closed when powered off, and send out alarm. The switch supports 1 relay alarm information output that supports DC power supply alarm and port alarm information output. It can be connected to alarm light, alarm buzzer or other switching value collecting devices; it can timely inform operators when the alarm occurs.

DIP Switch Settings

The device provides 4-pin DIP switch for function setting, in which “ON” is the enabled end. The device needs to be powered on again to change the status of DIP switch.
DIP switch definition as follow:

DIP Definition Operation
1 Restore Factory Settings Set the DIP switch to ON, the device will root

automatically and restore to factory settings, then turn off the DIP switch.
2-4| Reserved| —

Console Port Connection

The series products provide 1 program debugging port based on RS232 serial port which can conduct device CLI command management after connecting to PC. The interface adopts RJ45 port, the RJ45 pin definition as follows:

Pin No. 2 3 5
Pin Definition TXD RXD GND

Checking LED Indicator

The device provides LED indicators to monitor the device working status with a comprehensive simplified troubleshooting; the detailed status of each LED is described in the table as below:

LED Indicate Description
P1/P2 ON PWR is connected and running normally
OFF PWR is disconnected or running abnormally
ALM ON Power supply or port link has alarm
OFF Power supply and port link have no alarm
RUN ON The device is powered on or the device is abnormal.
OFF The device is powered off or the device is abnormal.
Blinking Blinking 1 time per second, system is running normally
Link/Act (G1-G10) ON The Ethernet interface has established a valid network

connection.
Blinking| The Ethernet interface is in a network activity state.
OFF| The Ethernet port has not established a valid network connection

Logging in to WEB Interface

This device supports WEB management and configuration.
Computer can access the device via Ethernet interface. The way of logging in to device’s configuration interface via IE browser is shown as below:
Step 1: Configure the IP addresses of computer and the device to the same network segment, and the network between them can be mutually accessed
Step 2: Enter device’s IP address in the address bar of the computer browser  Step 3: Enter device’s username and password in the login window as shown below

Step 4: Click “OK” button to login to the WEB interface of the device.

Note:

  • The default IP address of the device is “192.168.1.254”.
  • The default user name and password of the device are “admin”.
  • If the username or password is lost, user can restore it to factory settings via device DIP switch or management software; all modified configurations will be cleared after restoring to factory settings, so please backup configuration file in advance.
  • Please refer to user manual for specific configuration method of logging in to WEB interface and other configurations about network management function.

Specification

Panel|
---|---
Gigabit copper port| 10/100/1000Base-T(X), RJ45, Automatic Flow Control, Full/Half Duplex Mode, MDI/MDI-X Autotunning
2.5G SFP| 100/1000 Base-X self-adaption or 100/1000/2.5G Base-X forced mode, SFP slot
Console port| CLI command management port (RS-232), RJ45
Alarm interface| 6-pin 5.08mm pitch terminal blocks, including 2-pin alarm terminal blocks. It supports 1 channel relay alarm information output, current load capacity is 1A@30VDC or 0.3A@125VAC
Indicator| Running Indicator, Port Indicator, Power Supply Indicator, Alarm Indicator
Switch Property|
Backplane bandwidth| 30G
Packet buffer size| 4Mbit
MAC Address Table| 8K
Power supply|
Input power supply| 12-48VDC, dual power supply redundancy, support non- polarity
Access terminal block| 6-pin 5.08mm pitch terminal blocks, power supply occupies 4 pins
Power consumption|
No-load| 8.9W@30VDC
Full-load| 4.0W@30VDC
Working Environment|
Working temperature| -40~75°C
Storage temperature| -40-85°C
Working humidity| 5%~95%(no condensation)
Protection grade| IP40 (metal shell)

Disposal of Waste Electrical and Electronic Equipment (WEEE 2012/19/EU)

(Applicable in the EU-member states)
The crossed-out wheeled bin symbol on the equipment or its packaging indicates that the product, at the end of its service life, shall not be mixed with unsorted municipal waste but and regulations. should be collected separately, in accordance with local laws A proper separate collection of end-of-life equipment for the subsequent recycling, treatment and environmentally compatible disposal, will help prevent potential damage to the environment and human health, facilitating the reuse, recycling and/or recovery of its component materials.
Private users should contact their vendor or municipal waste management service and ask for disposal information.
Professional users should contact their suppliers and check the terms of their selling agreement. This product must not be disposed of with other commercial waste.
Users’ cooperation in the correct disposal of this product will contribute to saving valuable resources and protecting the environment.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

3onedata User Manuals

Related Manuals