SuperFish UV-lamp UVC 9/18W AquaClear Pond Clear User Manual

June 6, 2024
SuperFish

User manual

AquaClear UVC 9 Watt – 18 Watt

Translation of the original manual.
SuperFish AquaClear UVC 9 Watt and 18 Watt
General instructions
Read this manual carefully before using this device. Keep this manual for future reference.
Meaning of symbols
The following warning symbols and/or signal words are used in this manual:
DANGER!
This means an imminent danger due to electric current. Failure to follow the safety instructions can result in serious or fatal injury and/or serious damage to the product or environment.
WARNING!
This means a dangerous situation due to UV-C radiation. Failure to follow the safety instructions can result in serious eye damage and damage to the skin.
WARNING!
This means a dangerous situation. Failure to follow the safety instructions can result in moderate or minor personal injury and/or damage to the product or environment.
NOTICE!
This means caution, useful information or advice.
Fig. … This refers to the relevant drawing … on pages 2 and 3 of this manual.
Meaning of the symbols on the device itself:
** This UVC device produces harmful radiation, direct contact can be dangerous for the eyes and skin. Always turn off the UV lamp before opening it.
This device complies with all applicable EU standards.
This device may not be disposed of with normal household waste but must be collected separately for recycling.
Use
**
Only suitable for indoor use for aquarium purposes.
The UVC device may only be connected if there is a sufficient flow of water.
This UVC should be only used for cleaning aquarium water and the water temperature should not exceed 35°C. It should never be used for other liquids or chemicals.

Model AquaClear UVC 9W AquaClear UVC 9W
UV-lamp 9 Watt 18 Watt
Max. pump capacity 1000 L/h 2000 L/h
Aquarium content 0-300 L 0-600 L
Hose connectors ø 12/16/20 mm  ø 12/16/20 mm
Cable length 2 metres 2 metres

Safety

Always follow the safety instructions below for safe use of the device. Failure to follow these instructions may endanger persons or the environment.

  • WARNING! This UVC device emits UV-C radiation, which can cause serious eye damage and/or damage to the skin. The UV lamp must therefore always be installed completely shielded from the eyes.
  • **** Never look at a burning UV lamp. Do not switch on the lamp until it is fully shielded installed and fully submerged.
  • This device must be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mm.
  • Ensure the voltage shown on the label matches the main supply voltage.
  • This device must be connected to a socket that is earthed.
  • Protect the socket and plug against moisture. Use a drip loop to ensure that water cannot reach the socket via the cord.
  • Don’t use the product if the device or quartz glass is damaged. Replace the quartz glass or return the device to your dealer for repair or recycling.
  • If the power cord or plug of the UVC is damaged, the unit head should be replaced.
  • Be careful with the combination of water and electricity. Do not operate with wet hands. Dry hands before carrying out maintenance.
  • Always switch off all devices in the aquarium before maintenance. Disconnect the plug(s) from the socket.
  • **** NOTICE! The UV lamp becomes warm. The UV lamp becomes warm. Allow the lamp to cool for at least 10 minutes before carrying out maintenance.
  • ****This device can be used by children aged from 8 years and above, persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, if they have been given supervision or instructions concerning the use of the device in a safe way understand the hazards involved. Children shall not play with the device.
  • Cleaning and maintenance of the device shall not be done by children without supervision.
  • Modifications to the device may affect safety. The warranty will also expire.
  • Aquadistri is not liable for any problems, damage or accidents due to incorrect use of this device.

Function
The Aquarium UVC ensures crystal-clear water. The UV lamp produces ultraviolet light with a wavelength of exactly 254 nm, thus meaning the best effectiveness at this wavelength. The sterilizing UV lamp reduces pathogenic bacteria, thereby reducing the risk of infection via the water. The UV radiation gives no fluctuations to water values and no detrimental effect on the purification bacteria in the filter.

Installation

Fig. A Always installs the UVC device outside the aquarium, with the aquarium water flowing through the UVC device and through the external filter. As the purification bacteria in the filter do not come into contact with the UV light, the biological filtration is not adversely affected.
Fig. B Cut the hose connectors (a) on the same diameter as the diameter of the hose. Unscrew the hose connectors from the UVC device before starting the sawing, to avoid damaging the UVC device.

  • Screw the hose connectors with the rubber gaskets (b) back onto the UVC device.

  • Connect the hoses from the external filter to the hose connectors of the UVC device. Secure the hoses with hose clamps.

  • Switch on the filter pump and check for any leaks.

  • Then turn on the UVC device by plugging in the power cord.
    Fig. C Check the operation of the UV lamp via the light indicator on the UVC device.

  • To avoid UVC overheating, switch off the UVC device when no water is flowing past it.

Maintenance

  • Check monthly if the UV lamp is burning via the light indicator on the UVC device.

  • Remove the plug from the socket before carrying out maintenance!

  • The UVC device should be cleaned twice a year.

  • The lamp is hot, wait 10 minutes after switching off before opening the UVC device.

  • Ensure that the water is drained out of the UVC device first, before opening the device.
    Fig. D Slide the red switch lock (o) to unlock the electrical part/unit head and housing.

  • Turn the unit head (p) counter-clockwise against the stop and carefully pull it out of the housing.

  • Clean the inside of the housing (e) with a clean brush or cloth and rinse with clean tap water.
    Fig. E Loosen the locking screw (n) from the unit head, screw off the locknut (g). Pull off the quartz glass (h) including the gasket (l) by a slight rotary movement.

  • Clean the quartz glass outer face with a soft cloth and SuperFish Pump & UVC Clean carefully. After cleaning, thoroughly rinse the quartz glass with clean tap water and check for damage. Replace the quartz glass if it shows any damage (to prevent glass breakage). Quartz glass replacement kit for the AquaClear UVC 9W (Art. 06010350) and for the AquaClear UVC 18W (Art. 06010355).

  • The UV lamp should be replaced yearly. Although the lamp may still burn, it no longer emits enough UV radiation (maximum 8000 operating hours). Replacement lamp for AquaClear UVC 9W: SF UV PL-lamp 9 W G23-167 mm (Art. 06011015) and for AquaClear UVC 18W: SF UV PL-lamp 18 W G23-236 mm SP (Art. 06010140).
    Fig. F Remove the old lamp (j) together with clip (i) and tube protection ring (k) and remove the O-ring.
    Fig. G Slide the tube protection ring (k) over a new UV lamp and put the clip (i) on the end of the UV tube.
    Fig. H Insert the new UV-lamp (j) in the fitting of the unit head.
    Fig. I Slide the quartz glass (h) gently over the UV lamp and insert the quartz glass with the gasket in the unit head.
    Fig. J Slide the locknut (g) over the quartz glass and tighten it onto the unit head.

  • Place back the locking screw (n) to lock the locknut.
    Fig. K Place the unit head (p) with fitted UV-lamp and quartz glass back into the housing (e) correctly and lock the red switch (o).

  • Check the whole assembly for possible leaks and check if the UV lamp is working.

a Hose connector
b Rubber gasket
c Clip
d Self-tapping screw| e UVC housing
f Fixing foot
g Quarts locknut
h Quartz glass| i UV tube clip
j UV tube
k Tube protection ring
l Gasket| m O ring
n Locking screw
o Switch lock (red)
p Electrical part/unit head
---|---|---|---

Recycling
This symbol indicates that this product (if it is discarded) may not be disposed of with normal household waste.
Instead, it must be handed in at an official collection center (e.g. HWRC). Or can be returned to the dealer when purchasing a similar new product. Follow the applicable rules in your country for the separate collection of electrical and electronic products. Separate collection and recycling are better for the environment, public health and reduce waste.
Warranty
2 years manufacturer’s warranty on materials and construction defects. Devices must be returned complete with all components, accompanied with an official proof of purchase confirming a purchase date for any warranty claims. Incomplete devices of which parts are missing, and devices without proof of purchase are not eligible for warranty. After receiving and checking, we will determine whether the device will be repaired or replaced. For a device repaired or replaced under warranty, the remaining time of the original warranty period applies. Carefully read the instructions on installation, use and maintenance. Damage due to incorrect use, damage due to contamination or not cleaning the device, glass breakage and damage to the cord are not covered by the warranty. Always keep the proof of purchase, without proof of purchase the warranty will be void!

Important, clean your UVC device at least twice a year!
Dirt and calcification reduce the UV-light permeability. Descale your quartz glass at least twice a year, for smooth, long-term use. In areas with extremely hard water, you may need to descale more often. Technical problems caused by scale are not under warranty. For cleaning and descaling, the quartz glass special SuperFish Pump & UVC Clean is available at your dealer.www.aquadistri.com

Vlietweg 8, 4791 EZ Klundert, The Netherlands, info@aquadistri.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals