3onedata IES6210-8T2GC-2P48 Managed Industrial Ethernet Switch Installation Guide

June 2, 2024
3onedata

3onedata IES6210-8T2GC-2P48 Managed Industrial Ethernet Switch

Specifications:

  • Model I: IES6210-8T2GC-2P48
  • Model II: IES6210-8T2GC-P220
  • Managed DIN-Rail industrial Ethernet switches
  • 8 100M copper ports + 2 Gigabit Combo ports
  • Power supply options: 2 48VDC power supplies or 1 220VAC power supply

Product Overview

The IES6210 Series are managed DIN-Rail industrial Ethernet switches designed for industrial use. The models include a variety of port configurations and power supply options to meet different needs.

AC Panel Design:

Features various ports, a console port, grounding screw, DIN-Rail mounting kit, and indicators for device status and power input.

DC Panel Design:

Includes power input terminal block, relay alarm output terminal block, console port, grounding screw, DIN-Rail mounting kit, and indicators for device status and power input. Some models also have a POE indicator.

Mounting Dimension:

Unit: mm. Instructions on how to mount the device onto a DIN-Rail securely are provided. Ensure proper installation before mounting.

DIN-Rail Mounting:

The product adopts 35mm standard DIN-Rail mounting. Insert the bottom of the DIN-Rail mounting kit into the DIN-Rail, then securely attach the device following the provided steps.

Usage Instructions:

  1. Check package contents for completeness.
  2. Ensure device is not placed in areas near water or moisture.
  3. Confirm supported power supply specifications before powering on.
  4. Avoid direct contact with the device’s surface when it’s running due to high temperature.
  5. Follow proper steps for powering on and off the device.

FAQ

Q: What should I do if any package item is damaged or lost?

A: Contact the company or dealers immediately for assistance in resolving the issue.

Q: How do I disassemble the DIN-Rail?

A: Power off the device, lift it slightly upwards, then shift out the top and bottom of the DIN-Rail mounting kit to disassemble.

  • Address:
    3/B, Zone 1, Baiwangxin High Technology Industrial Park, Xili, Nanshan District, Shenzhen

  • Website:
    www.3onedata.com

  • Tel:
    +86 0755-26702688

  • Fax:
    +86 0755-26703485

Package Checklist

Please check whether the package and accessories are intact while using the switch for the first time.

  1. Industrial Ethernet switch
  2. Certification
  3. DIN-Rail mounting attachment
  4. Warranty card
    If any of these items are damaged or lost, please contact our company or dealers, we will solve it ASAP.

Product Overview

This series are managed DIN-Rail industrial Ethernet switches. Models as follows:

  • Model I. IES6210-8T2GC-2P48 (8 100M copper ports + 2 Gigabit Combo ports + 2 48VDC power supplies)
  • Model II. IES6210-8T2GC-P220 (8 100M copper ports +2 Gigabit Combo ports +1 220VAC power supply)
  • Model III. IES6210-4T2GC-2P48 (4 100M copper ports + 2 Gigabit Combo ports + 2 48VDC power supplies)
  • Model IV. IES6210-4T2GC-P220 (4 100M copper ports + 2 Gigabit Combo ports + 1 220VAC power supply)
  • Model V. IES6210-8P2GC-2P24-120W (8 100M POE copper ports +2 Gigabit Combo ports +2 24VDC power supplies +120W POE power)
  • Model VI. IES6210-8P2GC-2P48-120W (8 100M POE copper ports +2 Gigabit Combo ports +2 48VDC power supplies +120W POE power)
  • Model VII. IES6210-8P2GC-2P48-240W (8 100M POE copper ports + 2 Gigabit Combo ports + 2 48VDC power supplies +240W POE power)
  • Model VIII. IES6210-4P2GC-2P24-60W (4 100M POE copper ports +2 Gigabit Combo ports +2 24VDC power supplies + 60W POE power)
  • Model IX. IES6210-4P2GC-2P24-120W (4 100M POE copper ports + 2 Gigabit Combo ports +2 24VDC power supplies + 120W POE power)
  • Model X. IES6210-4P2GC-2P48-120W (4 100M POE copper ports +2 Gigabit Combo ports +2 48VDC power supplies + 120W POE power)

AC Panel Design

Top view, Bottom view and Rear view

3onedata-IES6210-8T2GC-2P48-Managed-Industrial-Ethernet-Switch-
FIG-1

Side view

Model IV Model II

  1. AC power input terminal block
  2. Relay alarm output terminal block
  3. DIP switch
  4. Console port
  5. Grounding screw
  6. Wall-mounted location hole
  7. DIN-Rail mounting kit
  8. Device running indicator RUN
  9. Relay alarm indicator ALM
  10. Power supply input status indicator PWR
  11. 100M copper port
  12. Ethernet port indicator
  13. Combo port

DC Panel Design

Top view, Bottom view and Rear view

Side view

Model VIII, IX,X Model V, VI,VII DC

  1. power input terminal block
  2. Relay alarm output terminal block
  3. DIP switch
  4. Console port
  5. Grounding screw
  6. Wall-mounted location hole
  7. DIN-Rail mounting kit
  8. Device running indicator RUN
  9. Relay alarm indicator ALM
  10. Power input status indicator PWR
  11. 100M copper port
  12. Ethernet port indicator
  13. Combo port
  14. POE indicator

Mounting Dimension

Unit: mm

3onedata-IES6210-8T2GC-2P48-Managed-Industrial-Ethernet-Switch-
FIG-7

Attention before mounting:

  • Don’t place or install the device in area near water or moist, keep the relative humidity of the device surrounding between 5%~95% without condensation. Before power on, first confirm the supported power supply specification to avoid over-voltage damaging the device.
  • The device surface temperature is high after running; please don’t directly contact to avoid scalding.

DIN-Rail Mounting

The product adopts 35mm standard DIN-Rail mounting, which is suitable for most of the industrial scenes. Mounting steps as below:

3onedata-IES6210-8T2GC-2P48-Managed-Industrial-Ethernet-Switch-
FIG-8

  • STEP 1
    Check if the DIN-Rail mounting kit is installed firmly.

  • STEP 2
    Insert the bottom of DIN-Rail mounting kit (one side with spring support) into DIN-Rail, and then insert the top into DIN-Rail.
    Tips:
    Insert a little to the bottom, lift upward and then insert to the top.

  • STEP 3
    Check and confirm the product is firmly installed on DIN-Rail, then mounting ends.

Disassembling DIN-Rail

  • STEP 1
    Device power off.

  • STEP 2
    After lift the device upward slightly, first shift out the top of DIN-Rail mounting kit, then shift out the bottom of DIN-Rail, disassembling ends.

Notes before power on:

  • Power ON operation: first connect power line to the connection terminal of device power supply, then power on.
  • Power OFF operation: first unpin the power plug, then remove the power line, please note the operation order above.

Power Supply Connection

DC power supply 24VDC

3onedata-IES6210-8T2GC-2P48-Managed-Industrial-Ethernet-Switch-
FIG-9

Power input voltage of model VI model VIIand model X: 48VDC, power input voltage of model I and model III: 48VDC (12~48VDC).

AC power supply 220VAC
This series of model II and model IV
support AC single power supply and provide 6 pins 5.08mm pitch input terminal blocks, including 4 pins power supply terminal blocks on the left side.
Power input voltage: 220VAC (85~264VAC).

PoE Power Supply Pin Connection

3onedata-IES6210-8T2GC-2P48-Managed-Industrial-Ethernet-Switch-
FIG-10

Relay Connection

  • The device provides 6-pin 5.08mm pitch input terminal blocks, including 2-pin  relay terminal blocks on the right side.
  • Relay terminals are a pair of normally open contacts in device alarm relay.
  • They are open circuit in normal non alarm state, closed when any alarm information occurs. Such as: it’s closed when power off, and send out alarm. The switch supports 1 channel relay alarm information output, support DC power alarm information or network abnormal alarm output, it can be connected to alerting lamp, alarm buzzer, or other switching value collecting devices for timely warning operating staffs when alarm information occurs.

DIP Switch Settings

Provide 4 pins DIP switch for function settings, where “ON” is enable valid terminal. Please power off and power on after changing the status of DIP switch. DIP switch definition as

DIP Deffoinlliotwiosn: Operation

1

| Restore factory defaults| Set the DIP switch to ON, power on the device again, it will restore to factory settings, then
DIP| Definition| Operation
---|---|---
 |  | turn off the DIP switch.
2| Reserved| –

3

|

Upgrade

| Set the DIP switch to ON, the program of this device can be upgraded, then turn off the DIP switch when this upgrade completes.
4| Reserved| –

Console Port Connection

The device provides 1 channel procedure debugging port based on serial port, and can conduct device CLI command line management after connected to PC. The interface adopts RJ45 port, the RJ45 pin definition is as follows:

Pin No. 2 3 5
Definition TXD RXD GND

Checking LED Indicator

The function of each LED is described in the table as below:

LED Status Description

P1/P2/PWR

| ON| Power supply is connected and running normally

OFF

| Power supply is disconnected and running abnormally.

ALM

| ON| Power supply, port link

alarm

OFF| Power supply, port link

without alarm

RUN

| ON| The device is powered on or

the device is abnormal.

OFF| The device is powered off or

the device is abnormal.

Blinking| System is running well.

Link/ACT

(1-4/8, G1-G2)

| ON| Ethernet port connection is

active.

Blinking| Data transmitted
OFF| Ethernet port connection is
 |  | inactive.
---|---|---

POE (1-4/8)

| ON| POE port supply electricity for other devices normally
OFF| POE is disabled or disconnected

Logging in to WEB Interface

This device supports WEB management and configuration. Computer can access the device via Ethernet interface. The way of logging in to device’s configuration interface via IE browser is shown as below:

  • Step 1
    Configure the IP addresses of computer and the device to the same network segment, and the network between them can be mutually accessed.

  • Step 2
    Enter device’s IP address in the address bar of the computer browser.

  • Step 3
    Enter device’s username and password in the login window as shown below.

3onedata-IES6210-8T2GC-2P48-Managed-Industrial-Ethernet-Switch-
FIG-13

  • Step 4
    Click “OK” button to login to the WEB interface of the device.

Note:

  • The default IP address of the device is “192.168.1.254”.
  • The default username and password of the device is “admin”.
  • If the username or password is lost, user can restore it to factory settings via device DIP switch or management software; all modified configurations will be cleared after restoring to factory settings, so please backup configuration file in advance.
  • Please refer to user manual for specific configuration method of logging in to WEB interface and other configurations about network management function.

Specification

Panel|
---|---

100M POE copper port

| 10/100 Base-T(X) RJ45,

automatic flow control, full/half duplex mode, MDI/MDI-X autotunning, POE port, the output power consumption is 15W or 30W.

POE pins| V+, V+, V-, V- are

corresponding to 1, 2, 3, 6.

Gigabit Combo port| 10/100/1000Base-T(X) or

1000Base-X

Console port| CLI command management

port (RS-232), RJ45

Alarm interface

| 6-pin 5.08mm pitch terminal

blocks, including 2-pin alarm terminal blocks. It supports 1 channel relay alarm information output, current load capacity is 1A@30VDC or 0.3A@125VAC

Run indicator, interface

Indicator

| indicator power indicator, alarm indicator, PoE indicator
Exchange attributes|
Backplane bandwidth| 7.6G
Packet buffer size| 1Mbit
MAC table size| 8K
Power supply|

Input power supply

| Power supply input voltage: 48VDC, 24VDC, 220VAC

Support DC dual power supply

redundancy, anti-reverse

---|---

Access terminal

| 6-pin 5.08mm pitch terminal

blocks, including 4-pin power supply terminal blocks

Consumption|
No-load| ≤4.9W@48VDC
Full-load| ≤122.8W@48VDC
Working environment|
Working temperature| -40~75℃
Storage temperature| -40~85℃
Working humidity| 5%~95% (no condensation)
Protection grade| IP40 (metal shell)

Disposal of Waste Electrical and Electronic Equipment (WEEE 2012/19/EU)

(Applicable in the EU-member states)

  • The crossed-out wheeled bin symbol on the equipment or its packaging indicates that the product, at the end of its service life, shall not be mixed with unsorted municipal waste but should be collected separately, in accordance with
  • A proper separate collection of end-of-life equipment for the subsequent recycling, treatment and environmentally compatible disposal, will help prevent potential damage to the environment and human health,facilitating the reuse, recycling and/or recovery of its component materials.
  • Private users should contact their vendor or municipal waste management service and ask for disposal information.
  • Professional users should contact their suppliers and check the terms of their selling agreement.
  • This product must not be disposed of with other commercial waste.
  • Users’ cooperation in the correct disposal of this product will contribute to saving valuable resources and protecting the environment.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

3onedata User Manuals

Related Manuals