3onedata IES618 Series Managed Industrial Ethernet Switch Installation Guide

June 1, 2024
3onedata

3onedata-logo

3onedata IES618 Series Managed Industrial Ethernet Switch

3onedata-IES618-Series-Managed-Industrial-Ethernet-Switch-
PRODUCT

Specifications:

  • Model I: IES618 (8 100M copper ports, 12~48VDC dual power supplies)
  • Model II: IES618-2F (6 100M copper ports + 2 100M fiber ports, 12~48VDC dual power supplies)
  • Model III : IES618-4F (4 100M copper ports + 4 100M fiber ports, 12~48VDC dual power supplies)

Product Overview:
This series consists of 100M managed DIN-Rail industrial Ethernet switches. The devices come with grounding screws, a relay alarm output terminal block, a console port, DC dual power input terminal block, and a DIP switch.

Mounting Dimension:
Unit: mm

Package Checklist:
Ensure the package includes an Industrial Ethernet switch, DIN-Rail mounting switch attachment, Certification, and Warranty card. Contact the company or dealers if any item is damaged or lost.

Mounting Instructions

DIN-Rail Mounting:

  1. Check if the DIN-Rail mounting kit is firmly installed.
  2. Insert the bottom of the DIN-Rail mounting kit into the DIN-Rail, then insert the top.
  3. Confirm the product is securely installed on DIN-Rail.

Disassembling DIN-Rail:

  1. Power off the device.
  2. Shift out the top and bottom of the DIN-Rail mounting kit to disassemble.

Note before mounting:
Avoid placing the device in areas near water or moisture. Maintain relative humidity between 5%~95% without condensation. Confirm power supply specifications before powering on to prevent damage due to over-voltage. Avoid direct contact with the device surface post-operation to prevent burns.

Power Supply Connection:
DC dual power supply: The device provides a 4-pin power supply connection.

Contact Information: 3onedata Co., Ltd. Address: 3/B, Zone 1, Baiwangxin High Technology Industrial Park, Xili, Nanshan District, Shenzhen Website: www.3onedata.com Tel: +86 0755-26702688 Fax: +86 0755-26703485

Package Checklist

Please check whether the package and accessories are intact while using the switch for the first time.

  1. Industrial Ethernet
  2. DIN-Rail mounting switch attachment
  3. Certification 4 Warranty card If any of these items are damaged or lost, please contact our company or dealers, we will solve it asap.

Product Overview

These series are 100M managed DIN-Rail industrial Ethernet switches. For convenience, the products of this series adopt the following number on the left in this guide, please affirm the number of your product. Model I. IES618 (8 100M copper ports, 12~48VDC dual power supplies)

  • Model II. IES618-2F (6 100M copper ports + 2 100M fiber ports, 12-48VDC dual power supplies)
  • Model III. IES618-4F (4 100M copper ports + 4 100M fiber ports, 12-48VDC dual power supplies)

Panel design
Top view, bottom view and rear view

3onedata-IES618-Series-Managed-Industrial-Ethernet-Switch-FIG-
\(1\)

Front View

3onedata-IES618-Series-Managed-Industrial-Ethernet-Switch-FIG-
\(2\)

  1. Model I Model II Model III Grounding screw
  2. Relay alarm output terminal block
  3. Console Port
  4. DC dual power input terminal block
  5. DIP switch
  6. location hole of Wall-mounting panel
  7. DIN-Rail mounting kit
  8. Power input status indicator P1/P2
  9. Device running indicator RUN
  10. Relay alarm indicator ALM
  11. 100Base-FX 100M Ethernet fibre port
  12. 10/100Base-T(X) 100M
  13. Ethernet copper port Ethernet port Link indicator

Mounting Dimension

3onedata-IES618-Series-Managed-Industrial-Ethernet-Switch-FIG-
\(3\)

Note before mounting:

  • Don’t place or install the device in an area near water or moisture, keep the relative humidity of the device surrounding between 5%~95% without condensation.
  • Before power on, first confirm the supported power supply specification to avoid over-voltage damaging the device.
  • The device surface temperature is high after running; please don’t directly contact to avoid scalding.

DIN-Rail Mounting
The product adopts 35mm standard DIN-Rail mounting which is suitable for most industrial scenes, mounting steps as follows:

  1. Check if the DIN-Rail mounting kit is installed firmly.

  2. Insert the bottom of the DIN-Rail mounting kit (one side with spring support) into DIN-Rail, and then insert the top into DIN-Rail.
    Tips: Insert a little to the bottom, lift upward and then insert to the top.

  3. Check and confirm the products is firmly installed on DIN-Rail, then mounting ends.

Disassembling DIN-Rail

  1. Device powered off.
  2. After lifting the device upward slightly, first shift out the top of DIN-Rail mounting kit, and then shift out the bottom of DIN-Rail, disassembling ends.

Note before powering on:

  • Power ON operation: First insert the power supply terminal block into the device power supply interface, and then plug the power supply plug contact and power on.
  • Power OFF operation: First, remove the power plug, and then remove the wiring section of terminal block. Please pay attention to the above operation sequence.

Power Supply Connection

DC dual power supply

The device provides 4 pins power supply input terminal blocks and supports two independent DC power supply systems, PWR1 and PWR2, which supports non- polarity and anti-reverse connection function, that the device can work normally after reverse connection. Voltage range: 12~48VDC.

Relay Connection

Relay terminals are a set of normally open contacts of the device alarm relay. They are open circuit in the state of normal non alarm, closed when any alarm information occurs. For example, they are closed when powered off, and send out alarm. The product supports 1 relay alarm information output that can output DC power supply alarm information or network abnormality alarm. It can be connected to alarm light or alarm buzzer or other switching value collecting devices, which can timely inform operators when the alarm occurs.

DIP Switch Settings

The device provides 4 pins DIP switch for function setting, in which “ON” is the enabled end. The device needs to be powered on again to change the status of DIP switch.

DIP switches definition as follows:

DIP Definition Operation
1 Reserved
2 Upgrade Set the DIP switch to ON, the device can be upgraded, then turn

off the DIP switch when this

upgrade completes.

3| Restore factory defaults| Set the DIP switch to ON, power on the device again, it will restore

to factory settings, then turn off the DIP switch.

4| Reserved| –

Console Port Connection

The device provides 1 channel procedure 18debugging port based on RS232 serial port, and can conduct device CLI command line management after connected to PC.

The interface adopts RJ45 port, the RJ45 pin definition as follows:

Pin No. 2 3 5.

PIN

definition

| TXD| RXD| GND

Checking LED Indicator
The device provides LED indicators to monitor the device working status with a comprehensive simplified troubleshooting; the function of each LED is described in the table as below:

LED Indicate Description

P1/P2

| ON| PWR is connected normally| and| running
OFF| PWR is disconnected and running abnormally

ALM

| ON| Power supply, port link alarm
OFF| Power  supply,  port

alarm

| link| without

RUN

| ON| The device is powered on or the

device is abnormal.

OFF| The device is powered off or the

device is abnormal.

Blinking| Blinking 1 time per second, system

is running well.

Link/Act (1-8)

|

ON

| The Ethernet interface has

established an active network connection.

Blinking| The Ethernet interface is in a

network activity state.

Ethernet port has not established

OFF| valid network connection

Logging in to WEB Interface

This device supports WEB management and configuration. Computer can access the device via an Ethernet interface. The way of logging in to device’s configuration interface via IE browser is shown as below:

  1. Configure the IP addresses of computer and the device to the same network segment, and the network between them can be mutually accessed
  2. Enter device’s IP address in the address bar of the computer browser.
  3. Enter device’s user name and password in the login window as shown below.3onedata-IES618-Series-Managed-Industrial-Ethernet-Switch-FIG-  \(10\)
  4. Click “OK” button to login to the WEB interface of the device.

Notes:

  • The default IP address of the device is “192.168.1.254”. The default user name and password of the device is “admin”.
  • If the username or password is lost, user can restore it to factory settings via device DIP switch or management software; all modified configurations will be cleared after restoring to factory settings, so please backup the configuration file in advance.
  • Please refer to user manual for specific configuration method of logging in to WEB interface and other configurations about network management functions.

Specification

Panel

100M Copper Port| 10/100Base-T(X), RJ45, Automatic Flow Control, Full/half Duplex Mode, MDI/MDI-X Autotunning 100Base-FX, optional SC/ST/FC
---|---
100M fiber port| CLI command management port
Console Port| (RS-232), RJ45

2-pin 7.62mm pitch terminal

Alarm interface| blocks, support 1 relay alarm

output, current load capability is 1A@24VDC or 0.5A@120VAC

Power supply indicator, run

Indicator| indicator, interface indicator, alarm

indicator

Switch property|
Backplane bandwidth| 2G
Packet buffer size| 1Mbit
MAC Address Table| 2K
Power supply|
Input power supply| 12~48VDC, dual power supply redundancy, non-polarity
Access terminal block| 4 pins 7.62mm pitch terminal

blocks

Power consumption|
Model I| No-load: 1.38W@12VDC

Full-load: 3.47W@12VDC

Model II| No-load:3.11W@12VDC

Full-load: 5.68W@12VDC

Model III| No-load: 4.93W@12VDC

Full-load: 6.40W@12VDC

Working environment|
Working temperature| -40〜75℃
Storage temperature| -40〜85℃
Working humidity| 5%〜95% (no condensation)
Protection grade| IP40 (metal shell)

Disposal of Waste Electrical and Electronic Equipment (WEEE 2012/19/EU
(Applicable in the EU-member states)
The crossed-out wheeled bin symbol on the equipment or its packaging indicates that the product, at the end of its service life, shall not be mixed with unsorted municipal waste but should be collected separately, in accordance with
A proper separate collection of end-of-life equipment for the subsequent recycling, treatment and environmentally compatible disposal, will help prevent potential damage to the environment and human health, facilitating the reuse, recycling and/or recovery of its component materials. Private users should contact their vendor or municipal waste management service and ask for disposal information. Professional users should contact their suppliers and check the terms of their selling agreement. This product must not be disposed of with other commercial waste. facilitating the reuse, recycling and/or recovery of its component materials. Private users should contact their vendor or municipal waste management service and ask for disposal information. Professional users should contact their suppliers and check the terms of their selling agreement. This product must not be disposed of with other commercial waste. contribute to saving valuable resources and protecting the environment.

FAQ

Q: What should I do if I encounter issues with the power supply connection?
A: Ensure that the power supply terminal block is correctly inserted into the device power supply interface and securely connected. If issues persist, contact our customer support for further assistance.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

3onedata User Manuals

Related Manuals