BEGA 50042P Wall Ceiling Light LED Motion Instruction Manual

June 1, 2024
BEGA

25.23 · Technical amendments reserved

50 042 P

Ceiling and wall luminaire for indoor use

Instructions for use

Application
Ceiling and wall luminaire · indoor luminaire made of impact resistant synthetic diffuser and metal housing, for all lighting tasks. They are ideal for places where a soft and uniform lighting distribution is required.
Luminaire with motion sensor.

Product description
Metal housing, finish colour white
Impact resistant synthetic diffuser, white, with bayonet closure
Integrated HF-motion sensor, maximum range 10 m
2 mounting holes ø 5.5mm
Distance apart 230mm
2 cable entries for through-wiring for mains cable up to ø 10.5 mm max. 3 × 1.5
Connection terminal 2.5
Earth conductor connection
LED power supply unit
230 V ~ 50 Hz
BEGA Thermal Switch®
Temporary thermal shutdown to protect temperature-sensitive components
Safety class I
Impact strength IK10
Protection against mechanical
impacts < 20 joule
– Conformity mark
Weight: 2.1 kg
This product contains light sources of energy efficiency class(es) D, E

Safety
The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp
Module connected wattage                  26.4 W
Luminaire connected wattage              32.2 W
Rated temperature                            ta=25 °C
Ambient temperature                ta max =30 °C

50 042 PK27
Colour temperature                             2700 K
Colour rendering index                     CRI >90
Module luminous flux                        3845 lm
Luminaire luminous flux                    3276 lm
Luminaire luminous efficiency     101,7 lm/W

50 042 PK3
Colour temperature                            3000 K
Colour rendering index                    CRI >90
Module luminous flux                       3970 lm
Luminaire luminous flux                   3384 lm
Luminaire luminous efficiency    105,1 lm/W

50 042 PK4
Colour temperature                           4000 K
Colour rendering index                   CRI >90
Module luminous flux                      4135 lm
Luminaire luminous flux                  3522 lm
Luminaire luminous efficiency   109,4 lm/W

Luminaire with trim ring :
Before installing onto the mounting surface the luminaire housing must be inserted into the trim ring (accessory).

Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Pass the mains supply cable through the grommet into luminaire housing.
Fix luminaire housing with enclosed or any other suitable fixing material on to the mounting surface.
It is imperative to use the enclosed gaskets.
Dismantle the mains supply cable approx. 60 mm.
Pull silicone sleeves over the wires and make earth and electrical connection to the terminals.
Place the synthetic diffuser to the luminaire housing and observe that the cam pins fit into the notches of the synthetic diffuser.
Screw in synthetic diffuser by turning it clockwise.
Thus, you reach a safe and vibration-resistant holding of the synthetic diffuser.

To release the synthetic diffuser from the luminaire housing, turn it counter- clockwise.

   Brightness

   Dwell time

    Sensitivity

  1. HF-motion sensor
  2. Daylight sensor
  3. LED indicator

The built-in motion sensor operates at a frequency of 5.8 GHz.
By moving within the detection range the motion sensor switches on the LED module inside the luminaire with a defined dwell time – push-button “Dwell time”.
With a wall mounting height of 1.8 m or ceiling mounting height of 2.6 m, the maximum range is 10 meters (see sketch).

Wall                                           Ceiling

    Detection range

The max. wall mounting height is 2.7 m and the max. ceiling mounting height is 4.0 m, in which the range reduces significantly.
The range can be set individually – push-button “Sensitivity”.
It should be noted that metal parts which are mounted in close proximity to the luminaire can affect the range.

With the three integrated push-buttons (Brightness, Dwell time and Sensitivity) on the motion sensor, specific settings can be made.
The first keypress activates the setting function.
Press a push-button to switch each function to the next level, the LED indicator on the motion sensor flashes to confirm.
After reaching the highest level, the level setting begins with “Level 1”.

Number of flashes BEGA 50042P Wall Ceiling Light LED Motion -
d1

Step                                     Setting of Sensitivity / Range

Sensitivity         BEGA 50042P Wall Ceiling Light LED Motion -
d2 BUTTON

Number of flashes BEGA 50042P Wall Ceiling Light LED Motion -
d3

Step                                     Setting of dwell time

Dwell timeBEGA 50042P Wall Ceiling Light LED Motion -
d4 BUTTON

Number of flashes BEGA 50042P Wall Ceiling Light LED Motion -
d

Step                                     Setting of brightness

Brightness            BEGA 50042P Wall Ceiling Light LED Motion -
d6 BUTTON

After the 3 parameters brightness, dwell time and sensitivity have been set successfully the module will require a voltage break to save the changes.
The integrated light sensor can be set individually with the brightness levels on the ambient brightness – Press the button “Brightness”.
Further individual illumination levels can be used with the button “Brightness” and set with the “learning mode”.
Press button “brightness” (> 3 s) to enable the “learning mode”. There is a slow flashing of the LED indicator.
After about two minutes, the current brightness value is measured for one minute, the LED flashes faster.
After completion, the measured brightness value is saved and is available in stage 6 of “Brightness” as the new brightness value.
To simplify the initial operation, the settings have been made as follows:
Range = 75 % (7.5 m)
Dwell time = 10 s
Light sensor = daylight

Factory Reset
The motion sensor can be reset to factory settings (MICAS) by simultaneously pressing the buttons “Sensitivity” and “Dwell time” for about 5 s.
The factory settings are as follows:
Range = 75 % (7.5 m)
Dwell time = 900 s
Light sensor = daylight

Test mode
The test mode can be used to check the change of settings of the motion sensor.
Press button “Sensitivity” (> 3 s) to enable the “test mode”.
Each further keystroke of this push-button prolongs the test mode.
The active test mode is displayed by a flashing of the LED indicator (2 s interval).
After 3 minutes the test mode is automatically disabled.

Replacement of the LED unit
The designation of the LED unit is noted on a label in the luminaire.
The light colour and light output of BEGA replacement units correspond to those of the LED units originally fitted. The LED unit can be replaced by qualified persons using standard tools.
Disconnect from main supply.
Unscrew synthetic diffuser from luminaire housing by turning it counter- clockwise.
Disassemble LED unit.
Assemble LED replacement unit.
Note installation instructions of the LED unit.
Screw in synthetic diffuser by turning it clockwise.
A damaged synthetic diffuser must be replaced.

Accessory · Trim rings

For this luminaire metal trim rings in 3 enamel surfaces are optional available.
Trim rings are accessories and must be ordered separately.

|

Part. No

---|---
Colour white|

13 004

Colour palladium|

13 005

Colour glossy silver|

13 006

Spares

Synthetic cover                 15 000 456
HF-motion sensor            61 001 077
LED unit 2700 K        75 003 048 K2
LED unit 3000 K        75 003 048 K3
LED unit 4000 K        75 003 048 K4

BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · info@bega.com · www.bega.com