Westinghouse W-782 LED Retrofit Lamp Installation Guide

May 15, 2024
Westinghouse

INSTALLATION AND
SAFETY INSTRUCTIONS

W-782 LED Retrofit Lamp

CAUTIONS:

  • WARNING – Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaire electrical systems. If not qualified, do not attempt installation.
    Contact a qualified electrician.

  • WARNING – Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire.

  • SUITABLE FOR WET LOCATION.

  • DO NOT USE WITH DIMMERS.

  • Operating temperature: -25°C to 45°C.

  • SUITABLE FOR USE IN ENCLOSED LUMINAIRES. MIN. LAMP COMPARTMENT DIMENSIONS:
    Model| MIN. LAMP COMPARTMENT DIMENSIONS (LxWxH)
    ---|---
    ED23.5| 13.2”x10”x7.9”
    ED28| 16.2”x10”x10”

  • Don’t stare at the bright light for long periods of time, as it may cause injury to eyes.

  • This device is not intended for use with emergency exit.

  • Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

  • WARNING – To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.

  • Installers should not disconnect existing wires from lampholder terminals to make new connections at lampholder terminals. Instead installers should cut existing lampholder leads several inches away from the lampholder and make new electrical connections to lampholder lead wires by employing applicable connectors.

  • This product is rated 120-277V, however in the US it should only be used on branch circuits permitted in Section 210.6 of the US National Electrical Code for E26 or E39 (EX39) lampholders.

  • THE RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING JURISDICTION. PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH THE APPLICABLE AND APPROPRIATE ELECTRICAL CODES. THE INSTALLATION GUIDE DOES NOT SUPERSEDE LOCAL OR NATIONAL REGULATIONS FOR ELECTRICAL INSTALLATIONS.

  • This device complies with Part 15 of the FCC rules and has been tested and found to comply with the limits for a Class B digital device. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Any changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.

INSTRUCTION:

STEP 1: Disconnect power from the luminaire and follow proper lockout/tagout procedures before beginning installation or maintenance.
STEP 2: Remove the existing lamp. Dispose of the lamps per local equirements.
STEP 3: Disconnect and remove the existing ballast, capacitor, and ignitor. Dispose of the components per local requirements.
STEP 4: Connect the Line wire (Line/Hot) to the center contact (eyelet) of the lamp holder.
STEP 5: Connect the Neutral wire (Common) to the shell of the lamp holder.
STEP 6: Insert and screw in the LED Retrofit lamp into the lamp holder.
STEP 7: Close the wiring compartment. Watch to be sure the wires are not pinched, bound, or crimped when closing the compartment.
STEP 8: Switch on the power.

WIRING DIAGRAMS:

Replacing Self Ballasted CFL LampWestinghouse W 782 LED Retrofit Lamp -
WIRING DIAGRAMSReplacing HPS/HID LampWestinghouse W 782 LED Retrofit Lamp -
WIRING DIAGRAMS 1 and Westinghouse are trademarks of Westinghouse Electric Corporation.
Used under license by Westinghouse Lighting. All Rights Reserved. Made in China

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Westinghouse User Manuals

Related Manuals