FRIGIDAIRE FG7MQ iSEER Gas Furnaces Virginia Washington DC MD
Technical Specifications
Model: FG7MQ
Type: Fully Modulating, Variable Speed,Condensing Upflow/Horizontal Gas Furnaces
Induced Draft: 97.0 AFUE Input 60,000 – 120,000 Btuh
Warranty
The product comes with a limited warranty. For more details,please refer to the general terms of the limited warranty provided on the website www.frigidairehvac.com.
Features and Benefits
- Modulating heating operation
- 100% fired and tested
- Best packaging in the industry
- 30 second blower delay
- 30 second post purge
- Hot surface igniter
- Color coded wire harness
- Flexible category IV venting system
- High Static Blowers
- Low Boy Height
- Tubular primary heat exchanger
- 90 second fixed cooling cycle blower-off delay (TDR)
- LP convertible
- Diagnostic lights for easy troubleshooting without counting flashes
- Incorporates integrated control board
- Two piece door design
- Blower Compartment
- Sealed Vestibule
- iQ Drive Thermostat
Dimensions
- Dimension A: 22 1/4″
- Dimension B: 28″
- Dimension C: 23 1/2″
Model Identification Code
The model identification code for this product is: FG7MQ 060 D V B
Location of Furnace Components
Item | Component Name | Specifications |
---|---|---|
1 | Cabinet Width | -060D-VB |
2 | Cooling Airflow | -080D-VC |
3 | Input Heating Capacity | -100D-VC |
-120D-VD |
Airflow Data
Target CFM for Selected Circulating Air Temperature Rises,
F| Full Minimum| Full Minimum| Full Minimum| Full Minimum
---|---|---|---|---
45| 50| 55| 60
Accessories
There are various accessories available for the FG7MQ model.
Please refer to the FG7MQ KITS SKU for more information.
General Terms of Limited Warranty
For complete information on the warranty terms and conditions,please visit
the website www.frigidairehvac.com.
FAQ
Q: Where can I find the warranty details?
A: The warranty details can be found on the website
www.frigidairehvac.com.
Q: What is the AFUE rating for this product?
A: The AFUE rating for this product is 97.0.
Q: Is the product LP convertible?
A : Yes, the product is LP convertible.
Q: What is the purpose of the diagnostic lights?
A: The diagnostic lights are used for easy troubleshooting without
counting flashes.
TECHNICAL SPECIFICATIONS
FG7MQ
iSEER, Smartlite®
Fully Modulating. Variable Speed, Condensing
Upflow/Horizontal Gas Furnaces
Induced Draft – 97.0 AFUE
Input 60,000 – 120,000 Btuh
The high efficiency upflow gas furnace may be installed free standing in a
utility room, basement, or enclosed in an alcove or closet. Upflow/horizontal
units come ready for upflow or horizontal application. The extended flush
jacket provides a pleasing “appliance appearance.” Design certified by CSA for
application in Canada and the United States.
WARRANTY
-
10-year all-parts warranty.
-
10 Year Quality Pledge to replace the unit if the heat exchanger fails within the first 10 years of operation, to the original owner.
-
Consumer product registration required for 10 year
All Parts Warranty and Quality Pledge within a limited period of time after the installation. See current warranty document or visit our consumer web site listed on the back of this document for warranty details. -
When registered, this product is upgraded to a limited lifetime heat exchanger warranty.
FEATURES and BENEFITS
- iSEER: Energy efficient brushless DC (ECM) motor gives up to 1 SEER point efficiency gain in cooling.
- Modulating heating operation Includes:
- Modulating gas valve from 100% to 50% input in 5% increments.
- Time proportioning modulation down to 15%.
- Variable speed inducer and blower.
- 100% fired and tested: All units and each component are tested on the manufacturing line.
- Best packaging in the industry: Unique corner post design assures product will arrive to the homeowner dent free.
- 30 second blower delay: At start-up assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds).
- 30 second post purge: Increases life of heat exchanger.
- Hot surface igniter: Innovative application of a silicon nitride type igniter. Utilizes proven Smartlite® technology.
- Color coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
- Flexible category IV venting system: May be vertically or horizontally vented using either a one-pipe or two-pipe system for maximum flexibility in installation.
- High Static Blowers: All models equipped with high static blowers.
- Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
- Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger and stainless steel secondary heat exchanger assures a long life.
- 90 second fixed cooling cycle blower-off delay (TDR): increases cooling performance when matched with a NORDYNE coil.
- LP convertible: Simple burner orifice change for ease of convertibility.
- Diagnostic lights for easy troubleshooting without counting flashess: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy to recognize states without counting flashes.
- Incorporates integrated control board: with connections for electronic air cleaner and humidifier.
- Two piece door design: Enhances furnace appearance and uses captured screws to prevent losing door screws.
- Blower Compartment: Sealed door to reduce air leakage and insulated for ultra quiet operation.
- Sealed Vestibule: Reduces burner and inducer sound levels.
- iQ Drive Thermostat: Provides modulation down to 15% and is required for furnace operation.
DIMENSIONS
*MQ Model #’s| Dimension “A”| Dimension “B”|
Dimension “C”
---|---|---|---
060$-6″| 17 ½| 15 ⅞| 16 ⅛
080$-6#| 21| 19 ⅜| 19 ⅝
100$-6#
120$-6$| 24 ½| 22 ⅞| 23 ⅛
FG7MQ 97+ Modulating Upflow/Horizontal Series
MODEL IDENTIFICATION CODE
LOCATION OF FURNACE COMPONENTS
ITEM | COMPONENT NAME |
---|---|
1. | “LOWER !SSEMBLY |
2. | “LOWER $OOR 3WITCH |
3. | “URNER !SSEMBLY |
4. | &INISH &LANGE |
5. | &LAME 2OLL-/UT 3WITCH |
6. | &LAME 3ENSOR |
7. | &URNACE #ONTROL “OARD |
8. | ‘AS -ANIFOLD |
9. | ‘AS 6ALVE |
10. | )GNITER |
11. | )NDUCER !SSEMBLY |
12. | )NDUCER ,IMIT 3WITCH |
13. | -OTOR #HOKE (# AND $ CABINETS ONLY) |
14. | -OTOR #ONTROL “OARD |
15. | -OTOR #ONTROL “OX |
16. | 0RESSURE 3WITCHES |
17. | 4RANSFORMER |
SPECIFICATIONS
FG7MQ MODEL NUMBERS:| ****
-060D-VB
| ****
-080D-VC
| ****
-100D-VC
| ****
-120D-VD
---|---|---|---|---
)NPUT – “TUH (A)| 60,000 / 30,000| 80,000 / 40,000| 100,000 / 50,000| 120,000
/ 60,000
(EATING #APACITY – “TUH| 58,200 / 29,100| 77,600 / 38,800| 97,000 / 48,500|
116,400 / 58,200
AFUE| 97.0| 97.2| 97.4| 97.0
“LOWER $ X 7| 11 X 8| 11 X 10| 11 X 10| 11 X 10
-OTOR (.0. – 3PEED – 4YPE| 1/2 – 6ARIABLE| 3/4 – 6ARIABLE| 3/4 – 6ARIABLE| 1 – 6ARIABLE
-OTOR &,!| 6.2| 8.7| 8.7| 11.70
2ATED %XT. 30 – )N. 7.#.| 0.5| 0.5| 0.5| 0.5
4EMPERATURE 2ISE 2ANGE – Ž&| 30-60| 35-65| 35-65| 40-70
3HIPPING 7EIGHTS| 130LBS| 140LBS| 150LBS| 165LBS
NOTE: All models are 115V, 60 Hz. Gas Connections are 1/2″ N.P.T. AFUE = Annual Fuel Utilization Efficiency (a) Ratings to 2,000 ft. Over 2,000 ft. reduce 4% for each 1,000 ft. above sea level.
AIRFLOW DATA
Gas Input Rate (Btuh)
| Target CFM for Selected Circulating Air Temperature Rises, F
---|---
45| 50| 55| 60| ****
Constant
Full Input| Minimum Input| Full Input| Minimum
Input| Full Input| Minimum Input| Full Input|
Minimum Input
60,000| 1,110| 635| 1,000| 560| 940| 515| 850| 470| 950
80,000| 1,480| 850| 1,345| 740| 1,255| 685| 1,140| 625| 1,300
100,000| 1,850| 1,050| 1,680| 925| 1,565| 855| 1,460| 780| 1,760
120,000| 2,225| 1,270| 2,020| 1,115| 1,890| 1,025| 1,730| 940| 2,100
NOTE: This table lists the High and Low target CFMs for each maximum input rate and temperature rise. If the target CFM is more that 1,600 CFM, it is recommended that two return air openings into the furnace be used.
ACCESSORIES
FG7MQ KITS
Description| SKU
2″ #ONCENTRIC VENT KIT| 904177
3″ #ONCENTRIC VENT KIT| 904176
2″ 3IDE WALL VENT KIT| 904617
3″ 3IDE WALL VENT KIT| 904347
5.3. ,0 #ONVERSION KIT (0 TO 10,000 FT.) FOR 53 AND #ANADA| 904950
“OTTOM RETURN lLTER 20 PER BOX, “”” CABINET| 904916
“OTTOM RETURN lLTER 20 PER BOX, “#” CABINET| 904917
“OTTOM RETURN lLTER 20 PER BOX, “$” CABINET| 904918
3IDE RETURN lLTER KIT| 541036
.EUTRALIZER KIT| 902377
GENERAL TERMS OF LIMITED WARRANTY
NORDYNE will furnish a replacement for any part of this product which fails in
normal use and service within the first ten years of installation, in
accordance with the terms of the warranty.
For complete details of the Limited Warranty, including applicable terms and
conditions, see your local installer or contact the NORDYNE warranty
department for a copy.
8000 Phoenix Parkway | O’Fallon MO 63368-3827
Specifications and illustrations subject to change without notice and without
incurring obligations. Printed in U.S.A (05/2009)
212D-0509 (Replaces 212D-0309)
www.frigidairehvac.com
FRIGIDAIRE is a registered trademark of Electrolux Home Products Inc. and used under a license from Electrolux Home Products, Inc. © Nortek Global HVAC, LLC. All Rights Reserved.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>