WAC WT4 120V Track Surface Mount Instruction Manual

May 15, 2024
WAC

WAC LogoINSTALLATION INSTRUCTION
W Track Surface Mount 120V
WT4, WT8, WT12

SAFETY INSTRUCTION

IMPORTANT: NEVER attempt any work without shutting off the electricity.

  • Read all of these instructions before installing the track system.
  • Turn off power at main switch before installing or modifying the system.
  • Do not install within 6 inches of any curtain or combustible materials.
  • Do not install less than 5 feet above a floor.
  • Do not install in damp or wet locations.
  • Do not install concealed, or extended through building walls.
  • Do not attempt to energize anything other than a track light fixture.
  • Do not connect a track to more than one branch circuit. Although track light system may seem to operate acceptably, a dangerous overload of the neutral may occur and result in a risk of fire.
  • Check with a qualified electrician before wiring.
  • All of the installations shall be in accordance with NEC and all local codes.
  • Save these installation instructions and refer to them when additions or changes to the track configuration are made.

MOUNTING OPTIONS

A: Surface Mount

  • Mounting slots can be knocked out and are spaced every 12 inches for convenience.
  • Mount track flush to the surface and secure screws (included).WAC WT4 120V Track Surface Mount - FIG 1

B: Toggle Bolt Mount

  • Mounting slots can be knocked out and are spaced every 12 inches for convenience.
  • Hang track from the surface using toggle bolts (included).WAC WT4 120V Track Surface Mount - FIG 2

C: T-Bar Grid Mount

  • Mounting slots can be knocked out and are spaced every 12 inches for convenience.
  • Use WAC’s T-BARCLIP to mount track to 15/16” t-bar grid systems.
  • For other t-bar grid types, source appropriate mounting hardware by others.WAC WT4 120V Track Surface Mount - FIG 3

FEED OPTIONS

  • Make sure power is off before wiring.
  • Note the polarity indicator of the track and accessories.

Live End Connector (WEDL / WEDR)

  1. Slide live end connector into track and secured screw (FIG. 4A).
  2. Remove the cover.
  3. Bring feed through either the knock-out on the bottom of the connector or on the side of the connector (FIG. 4B).
  4. If bringing feed through the knock-out on the bottom of the connector be sure that the knock-out cover is installed on the side of the connector.
  5. Wiring (FIG. 4C).
  6. Replace the cover.

WAC WT4 120V Track Surface Mount - FIG 4

L CONNECTER (WLLC / WRLC)WAC WT4 120V Track Surface Mount - FIG
5

T CONNECTER (WLTC / WRTC)WAC WT4 120V Track Surface Mount - FIG
6

X CONNECTER (WXC)WAC WT4 120V Track Surface Mount - FIG
7

I POWER CONNECTOR (WIC)WAC WT4 120V Track Surface Mount - FIG
8

FLEXIBLE CONNECTER (WFC)WAC WT4 120V Track Surface Mount - FIG
9

ACCESSORY OPTIONS

  • Make sure power is off before connecting.
  • Note the polarity indicator of the track and accessories

The I Connector (WPC) must be placed directly between two track sections as shown in FIG. 5 before securing the screw.WAC WT4 120V Track Surface Mount -
FIG 10End Caps (WEC) should be inserted into the track and secured as shown in FIG. 6.WAC WT4 120V Track Surface Mount - FIG
11 FIELD CUTTING
Cut the track, insulation material, and copper busbars with one straight cut and remove any burrs that may have resulted from the cut as shown in FIG. 7.WAC WT4 120V Track Surface Mount - FIG 12

MAXIMUM LOAD
The drawings (FIG. 8A, FIG. 8B, FIG. 8C show the maximum permissible mechanical load by 2-circuit W tracks for luminaires or other loads in relationship to the fixation or suspension point. It includes both of the weights of the track system.WAC WT4 120V Track Surface Mount - FIG
13

TRACK HEAD OPTIONS

W TRACK LINE VOLTAGE / CFL TRACK HEAD

  1. Set circuit selector to 0.
  2. Set locking arm to unlock position.
  3. Align this tab to the slot on the track (FIG. 9A).
  4. Insert adapter (FIG. 9B, FIG. 9C).
  5. Set locking arm to lock position.
  6. Set circuit selector to 1 or 2.

WAC WT4 120V Track Surface Mount - FIG 14

CONVERTER (CV-2T-LV / CV-2T-MH) FOR J TRACK HEADS

  1. J track head insert converter (FIG. 10A).
  2. Set J track head ’s locking arm to lock position.
  3. Set circuit selector to 0.
  4. Set converter’s locking arm to unlock position.
  5. Align this tab to the slot on the track (FIG. 10B, FIG. 10C).
  6. Insert adapter.
  7. Set converter’s locking arm to lock position.
  8. Set circuit selector to 1 or 2.

WAC WT4 120V Track Surface Mount - FIG 15

waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585| Headquarters, East Manufacturing Facility
44 Harbor Park Drive
Port Washington, NY 11050| South East Manufacturing Facility
1600 Distribution Ct
Lithia Springs, GA 30122| Central Manufacturing Facility
1700 South J Elmer Freeway, Ste 100 Cedar Hill, TX 75104| West Manufacturing Facility
1750 S Archibald Ave
Ontario, CA 91761
---|---|---|---|---

WAC Lighting retains the right to modify the design of our products at any time as part of the company’s continuous improvement program.

WAC Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

WAC User Manuals

Related Manuals