- 1 Scope
- 2 Reference documents
- 3 Chemical systems ,voltages and designation
- 4 LR03 Battery Dimensions
- 5 Voltage and Short current
- 6 LR03 discharge performance :
- 7 Leakage Resistance
- 8 Safety Requirement
- 9 Inspection rules
- 10 Inspection for service output:
- 11 Instructions for use
- 12. Disply and storage
- 13 Storage life
- 14 Marks
- Documents / Resources
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
FuSpower LR03 Zinc Manganese Dry Battery Instruction Manual
FUSPOWER Inc.
4650 Arrow Hwy Ste E6/7 MONTCLAIR CALIFORNIA 91763 US
Alkaline Zinc-Manganese Dry Battery
Technology Specification
Customer
Part name Alkaline Zinc-Manganese Dry Battery
Model No AAA LR03 1.5V
Serial No
Produce No
Company address: 4650 Arrow Hwy Ste E6/7 MONTCLAIR
CALIFORNIA 91763 US
(Tel): 909-971-3484
E-mail: fuspowershop@gmail.com
1 Scope
This specification defines the technical requirements for 1.5V LR03Alkaline cells distributed by FUSPOWER Inc. If not otherwise specified, the technical requirements and dimensions for cells should meet or exceed the requirements of GB/T 8897.1-2008,GB 8897.2-2008
2 Reference documents
GB8897.1-2008(IEC60086-1:2000,IDT) Primary batteries-Part 1: General
GB8897.2-2008(IEC60086-2:2001,MOD) Primary batteries-Part 2: Physical and
technological specifications
GB8897.5-2006(IEC 60086-5:2005,MOD)Primary batteries-Part 5: Safety of
batteries with aqueous electrolyte
3 Chemical systems ,voltages and designation
3.1 Chemical systems:Alkaline manganese battery
Zinc-Manganese dioxide
3.2 Nominal voltage: 1.5V
3.3 Designation
IEC&GB(China): LR03; ANSI Number: AAA;
4 LR03 Battery Dimensions
5 Voltage and Short current
OCV measurment:The inner resistance of Voltage Metre is above 1MΩ
C.C.V. measurment: After 0.2±0.01 sec by R=5.0Ω
SCC measurment: ± 0.5%
6 LR03 discharge performance :
Initial:60 days after pruduction
Test condition: 20℃±2℃ and 60±15%RH
7 Leakage Resistance
8 Safety Requirement
Note 1: Thermal shock
Note 2 : Free fall
9 Inspection rules
10.1 Deliver inspection: Depending on GB2828
Routine inspection: Depending on GB2829 and QB/T2389
10 Inspection for service output:
10.1 9 samples shall be tested for service output
10.2 If the average value is equal to or more than the value of table1, and if the number of batteries showing a value less than 80% of the value of table 1 is 1 or less. The batteries are considered to conform to the requirement.
10.3 If the average value is less than the value of table 1,or if the number of batteries
showing a value less than 80% is 2 or more, the test shall be repeated with other 9 pieces. At the second test, if the average value is equal to or more than the value of table 1, and if the number of batteries showing a value less than 80% of the value of table1is1 or less, these batteries are considered to conform to the requirement.
10.4 At above second test, if the average value is less than the value of table 1, or if the number of batteries showing a value less than 80% of the value of table 1 is 2 or more, the batteries are considered not to conform to the requirement. third test shall not be performed.
11 Instructions for use
11.1 Always select correct size and grade of battery most suitable fot intended use.
11.2 Replace all batteries of a set at the same time
11.3 Clean the battery contacts and also those of the equipment prior to battery installation
11.4 Ensure that batteries are installed correctly with regard polarity(+and -);
11.5 Remove batteries from equipment which is not be used for an extend period of time;
11.6 Remove exhausted batteries promptly..
12. Disply and storage
12.1 Batteries shall be stored in well-ventilated dry and cool conditions
12.2 Battery cartons should not be piled up in severa layers,or should not exceed a specified height;
12.3 Batteries should not be exposed to direct sun ray for a long time or placed in areas where they get wet by rain. ;
12.4 Do not mix unpacked batteries so as to avoid mechanical damage and/or short circuit among each other
13 Storage life
Storage life of batteries are ten years long at 20℃±2℃ and RH 60±15%
14 Marks
15.1 Designation;
15.2 Polarity of terminals;
15.3 Nominal voltage;
15.4 Mercury content;
15.5 Name or trade mark , manufacturer or supplier ;
15.6 Cautionary advice
Schematic diagram of discharge:
……..END……..
If manufacturer want to modify the product technology specification, we won’t inform you additionally)
Documents / Resources
|
FuSpower LR03 Zinc Manganese Dry
Battery
[pdf] Instruction Manual
LR03 Zinc Manganese Dry Battery, LR03, Zinc Manganese Dry Battery, Manganese
Dry Battery, Dry Battery, Battery
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>