WAC LIGHTING R1GNT02 New Construction Downlight Installation Guide

June 13, 2024
WAC LIGHTING

INSTALLATION INSTRUCTION
Multi Stealth Recessed – New Construction HSG
R1GNT, R1GNTA, R1GNL, R1GNLA

 LIGHTING R1GNT02 New Construction Downlight

WARNING
IMPORTANT: NEVER attempt to do any work without shutting off the electricity.

  • Read all instructions before installing.
  • System is intended for installation by a qualified electrician in accordance with the National Electrical Code and local regulations.
  • Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch “OFF” the circuit breaker switch(es) that control the power to the fixture or room that you are working on.
  • Place the wall switch in the “OFF” position.

CAUTION
All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/cETL listing of this fixture.

OVERVIEW:

Housing models below are New Construction, Airtight IC:
Trimmed: R1GNT02 / R1GNTA02, R1GNT04 / R1GNTA04, R1GNT06 / R1GNTA06, R1GNT08 / R1GNTA08
Trimless: R1GNL02 / R1GNLA02, R1GNL04 / R1GNLA04, R1GNL06 / R1GNLA06, R1GNL08 / R1GNLA08
Housing models below are New Construction, Airtight Non-IC:
Trimmed: R1GNT12 / R1GNTA12
Trimless: R1GNL12 / R1GNLA12
Each housing requires a trim for a finished look. Refer to specification sheets for compatible trim options.
SPECIFICATIONS

Input: 120-277V, 50/60Hz
Dimming: ELV/TRIAC (120V Only) / 0-10V
Ceiling Thickness: ½” up to 1½” for Compatible Trims

IMPORTANT:
HOUSING-TRIM COMPATIBILITY

TRIM TYPE R1GNT/R1GNL R1GNTA/R1GNLA
Downlight (R1GD) Yes No
Wall Wash (R1GW) Yes No
Adjustable (R1GA) No Yes

R1GNTA/R1GNLA housings have a larger aperture than R1GNT/R1GNL models to accomodate adjustable trims. Be sure to locate the housing installation appropriately.
Reference TABLE. 1 on PAGE 5 to confirm the appropriate cut out detail associated with respective housings.
R1GNT02 / R1GNTA02 & R1GNL02 / R1GNLA02 **R1GNT04 / R1GNTA04 & R1GNL04 / R1GNLA04 **R1GNT06 / R1GNTA06 & R1GNL06 / R1GNLA06 R1GNT08 / R1GNTA08 & R1GNL08 / R1GNLA08
R1GNT12 / R1GNTA12 & R1GNL12 / R1GNLA12 **HOUSING INSTALLATION (TRIMMED):**

The housing features mounting brackets that can be used with hanger bars or various channel supports (See FIG. 1-5). Adjust the brackets to proper height by loosening the screws such that the bottom of housing is flush to top of finished ceiling plane (See FIG. 6). Retighten screws securely.
Slide the male and female hanger bars or other channel supports through the appropriate holes in the brackets.

FOR HANGER BAR INSTALLATION ON GRID:

1. Hanger bars are notched on the ends to fit over “T” bars in the suspended ceilings supported with tie wires (by others) to upper ceiling structure (See FIG. 7A). For R1GNT12 /R1GNTA12 housings, the mounting bracket is to be repositioned to the long side of the housing, at is center and used with supplied hanger bars (See FIG. 7B). This is achieved by undoing and reinstalled the three Philips screws that hold the mounting bracket in place.
Alternatively, other support channels may be used to support the housings (See FIG. 2-5 & 8). Once installed, the housing height may be adjusted as previously shown.

FOR HANGER BAR INSTALLATION ON JOISTS:

  1. Install the hanger bar and housing assembly such that the lip of the hanger bar rests on the bottom surface of the joist (See FIG. 9).

  2. Hanger bars include a captive mounting “screw-nail” for ease of installation. Align the bottom of the hanger bar with the bottom of the wood joist. Secure the “screw-nail” on each end by screwdriver (See FIG. 10A), or by hammer (See FIG. 10B).

  3. Slide fixture housing along bar hangers into desired location. Use locking screws to secure (See FIG. 10C).

  4. To shorten hanger bars to fit in a 12” joist, snap off one section of the hanger bars (See FIG. 11).

  5. Remove spring latched fixture junction box door and connect fixture wires to building wires: Insert each supply wire into appropriate junction box wire connector. This fixture features electronic low voltage (ELV), TRIAC, or 0-10V dimming capabilities
    (See FIG. 12). To utilize ELV or TRIAC, wire black (line hot), white (line neutral) and green (ground) in accordance to dimmer specifications.
    To utilize 0-10V dimming, wire purple (dim+), gray or pink (dim-), black (line hot), white (line neutral) and green (ground) in accordance to dimmer specifications.
    When not using a dimmer, connect the black fixture wire to hot, white fixture wire to neutral, and green fixture wire to ground. Leave all other wires capped individually.

  6. At the point of finishing the installation, create a rectangular cutout in the ceiling for the appropriate trim (See FIG. 13). Refer to the table on the next page for cutout dimensions and compatible trims.

  7. Refer to installation instructions for appropriate trims to complete the installation.

TABLE. 1: CEILING CUTOUT AND TRIM COMPATIBILITY

INSTALLATION| HOUSING  MODEL| HOUSING DESCRIPTION| TRIM MODEL| TRIM orsawnoN| CUTOUT DIMENSION
---|---|---|---|---|---
IC| R1 GNTO2| 2 CELL NC HSG (TRIM)| RI GDT02| 2 CELL DOWNLIGHT (TRIM)| 3 3/4″ x 2 1/16″
R1GNLO2| 2 CELL NC HSG (TRIMLESS)| RI GDLO2| 2 CELL DOWNLIGHT (TRIMLESS)
121 GNTA02| 2 CELL NC HSG ADJ (TRIM)| R1 GATO2| 2 CELL ADJUSTABLE (TRIM)| 4 3/16″ x 2 9/16″
R1 GNLA02| 2 CELL NC HSG ADJ (TRIMLESS)| R1 GAL02| 2 CELL ADJUSTABLE (TRIMLESS)
IC| WIGNTO4| 4 CELL NC HSG (TRIM)| Ft1 GDT04| 4 CELL DOWNUGHT (TRIM)| 6 3/4″ x 2 1/16″
R1GWTO4| 4 CELL WALL WASH (TRIM)
121 GNLO4| 4 CELL NC HSG (TRIMLESS)| R1 GDLO4| 4 CELL DOWNUGHT (TRIMLESS)
R1GWL04| 4 CELL WALL WASH (TRIMLESS)
WIGNTA04| 4 CELL NC HSG ADJ (TRIM)| R1 GATO4| 4 CELL ADJUSTABLE (TRIM)| 73/16’x2112″
R1GNLA04| 4 CELL NC HSG ADJ (TRIM)| R1GAL04| 4 CELL ADJUSTABLE (TRIMLESS)
IC| RI GNTO6| 6 CELL NC HSG (TRIM)| 111GDT06| 6 CELL DOVVNLIGHT (TRIM)| 9 3/4″ x 2 1/16″
111 GNLO6| 6 CELL NC HSG (TRIMLESS)| R1 GDLO6| 6 CELL DOWNLIGHT (TRIMLESS)
111GNTA06| 6 CELL NC HSG ADJ (TRIM)| R1 GATO6| 6 CELL ADJUSTABLE (TRIM)| 10 3/16″ x 2 1/2″
R1 GNLA06| 6 CELL NC HSG ADJ (TRIMLESS)| 111GAL06| 6 CELL ADJUSTABLE (TRIMLESS)
IC| R1GNTO8| 8 CELL NC HSG (TRIM)| 111GDT08| 8 CELL DOWNLIGHT (TRIM)| 12 11/16″x 2 1/16″
R1GWTO8| 8 CELL WALL WASH (TRIM)
R1GNLO8| 8 CELL NC HSG (TRIMLESS)| RI GDLO8| 8 CELL DOWNLIGHT (TRIMLESS)
R1GWL08| 8 CELL WALL WASH (TRIMLESS)
Ft1 GNTA08| 8 CELL NC HSG ADJ (TRIM)| R1 GATO8| 8 CELL ADJUSTABLE (TRIM)| 13 1/4″ x 2 1/2″
R1 GNLA08| 8 CELL NC HSG ADJ (TRIMLESS)| 111GAL08| 8 CELL ADJUSTABLE (TRIMLESS)
NON-IC| R1GNT12| 12 CELL NC HSG (TRIM)| RIGDT12| 12 CELL DOWNLIGHT (TRIM)| 18 5/8″ x 2 1/16″
RI GINTI2| 12 CELL WALL WASH (TRIM)
R1GNL12| 12 CELL NC HSG (TRIMLESS)| RI GDL1 2| 12 CELL DOWNLIGHT (TRIMLESS)
RI GWLI 2| 12 CELL WALL WASH (TRIMLESS)
RI GNTAI 2| 12 CELL NC HSG ADJ (TRIM)| R1 GAT1 2| 12 CELL ADJUSTABLE (TRIM)| 195/16″x21/2″
R1GNLAl2| 12 CELL NC HSG ADJ (TRIMLESS)| R1GAL12| 12 CELL ADJUSTABLE (TRIMLESS)

Abbbreviations:
NC – New Construction
HSG – Housing
ADJ – Adjustable

HOUSING INSTALLATION (TRIMLESS):

  1. Refer to and complete previous STEPS 1-5 on PAGE 4. Secure the trimless spackle frame (provided with the trimless light engine assembly) to the housing using the four screws provided (See FIG. 14).
    NOTE: Six screws are required for the R1GNL12 housing.

  2. Insert the plaster shield into opening of housing. Apply plaster or spackle over trimless spackle frame and sand surface when dry for finished look. Remove the plaster shield when finishing is complete. (See FIG. 15-16)

  3. Refer to installation instructions for appropriate trims to complete the installation.

DRIVER REPLACEMENT:

To replace the driver, first remove trim from housing aperature:

  1. To remove the current driver assembly, use a finger, and grab the driver pull tab to slide it towards the opening of the housing (See FIG. 17). Undo the input quick disconnect wiring.

  2. To install the replacement driver assembly, use a flat head screwdriver to hook onto the replacement driver bracket and push it through the housing opening (See FIG. 18). Make appropriate quick disconnect wiring connections for input wiring.

  3. Push the driver assembly tab to the driver guide rails and proceed to slide it inward to the driver cradle, until an audible “CLICK” is heard (See FIG. 19).

WAC Lighting retains the right to modify the design of our products at any time as part of the company’s continuous improvement program.

waclighting.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
MARCH 2022

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

WAC LIGHTING User Manuals