Product Data

Output LED Channel 1
DC Voltage 3-42V
Current 100-500mA via NFC tool; Min.current gear lower to 0.1mA, default

250mA
Current Accuracy| ±3%( ±1%@Certain full load) @ full load
Rated Power| Max. 10W
Input| Voltage Range| 220-240VAC/220-240VDC
Absolute Voltage Range| 198-264VAC/198-264VDC
Frequency Range| 0/50/60Hz
Power Factor (Typ.)| > 0.95 @ 230VAC Full load
Total Harmonic Distortion| THD ≤ 8% (@ full load / 230VAC)
Efficiency (Typ.)| >80% @ 230VAC full load
AC Current (Typ.)| 0.1A @ 230VAC
Inrush Current (Typ.)| Max. 3.16A at 230VAC; 72μs duration
Leakage Current| < 5mA /230VAC
Standby  Power  Consumption| <0.5W
Anti Surge| L-N:2KV
Control| Dimming Interface| DALI Device Type 6 (DALI consumption < 2mA)/ AC Push
Dimming Range| 0.01%-100%@ Max current
Dimming Method| Amplitude/CCR dimming
Dimming Curve| Linear/ Logarithmic optional
Protection| Short Circuit| Yes, recovers automatically after fault condition is removed
Over Current| Yes, recovers automatically after fault condition is removed
Over Temperature| Yes, recovers automatically after temperature drop
Environment| Working Temp.| -25℃ ~ +60℃
Max. Case Temp.| Tc=85℃
Working Humidity| 10% ~ 95% RH non-condensing
Storage Temp. & Humidity| -40℃ ~ +80℃, 10% ~ 95% RH
Safety & EMC| Safety Standards| EN61347-1,   EN61347-2-13
Withstand Voltage| I/P-O/P: 3.75KVAC
Isolation    Resistance| I/P-O/P: 100M Ohms / 500VDC / 25℃ / 70% RH
EMC Emission| En55015, EN61000-3-2, EN61000-3-3
EMC Immunity| En61547,    EN61000-4-2,3,4,5,6,8,11
Others| MTBF| 191350H, MIL-HDBK-217F @ 230VAC full load and 25℃  ambient temperature
Dimension| φ57x24mm (D*H)
Warranty| 5 Years

  • In compliance with IEC 62386-101:2014, IEC 62386-102:2014, IEC 62386-207 Ed2
  • Built-in DALI-2 interface, DALI DT6 device
  • Dimmable LED driver. Max. output power 10W
  • 100-500mA current selectable via NFC program tool. Min.current gear lower to 0.1mA
  • DALI Address/Group/Scene setting via NFC program tool.
  • Class Ⅱ power supply, full isolated plastic case
  • High power factor and efficiency
  • ON/OFF and Dimming control
  • Amplitude/CCR dimming, smooth and deep dimming
  • Compatible with universal DALI masters that support DT6 commands
  • CLO function for a further upgraded experience
  • CD(Corridor Mode): auto light on when someone enters
  • IP20 rating, suitable for indoor LED lighting applications
  • 5 years warranty

Safety & Warnings

  • DO NOT install with power applied to the device.
  • DO NOT expose the device to moisture.

Operation

With DALI master

  1. DALI Address
    1 DALI address for 1 channel output are assigned by DALI Master controller automatically, please refer to user manuals of compatible DALI Masters for specific operations.
    With NFC Programming devices

Note

  1. Do wiring according to the wiring diagram and power on the DALI system .
  2. Recommend setting parameters without power-on the DALI devices .
  3. Please make sure your mobile phone has NFC function and enable it .

Working with “SR NFC Tool” APP
Step 1: Download the APP (searching “SR NFC Tool” from App Store and Google Play) .
Then open the APP . Note:

  1. Please Make sure that you have enabled NFC function with your mobile phone/ tablet .
  2. Please Make sure that the “NFC position” is matched.
  3. Please do not power on the device before setting.
  4. If you can’t download “SR NFC Tool”. Please contact with us.

Step 2 : Add device, and name it as you wish. Step 3: Unlock device, enter parameters configuring page. Note:

  1. You have to unlock the device then do some settings
  2. Only when the corresponding function is selected, the function interface will be displayed.

Step 4: Few parameter interface, you can choose the setting based on your requirements. Step 5: After setting, please save the selected configuration via NFC and power on the device. Tips

  1. NFC function doesn’t require any power driver.
  2. Many functions can be configured by NFC. Kindly check your desired functions.
  3. All of our DALI drivers are in the best performance within our DALI master/ DALI IoT gateway.

Note: Within Our NFC tech design, you shall probably have one of the largest NFC sensing are The More sensitive you’re able to touch, the more convenient you can have.

CLO AND CORRIDOR DIM(CD) FUNCTION INSTRUCTION

  1. Open APP, and Find the CLO/CD functions

  2. Enter CLO Setting homepage Tips:
    Working hours : Ability to calculate the working hours of a single driver.

  3. Corridor dim(CD) function

  4. Enter CD Setting homepage

Tips:

  1. You should select either CD mode or PD mode, but not both.
  2. Under CD mode, you can realize it with normal (3rd party) AC sensor.
  3. Default mode: PD mode.

Additional Remarks

  1. Please make sure your APP version is 1.0.10 or higher.
  2. Please make sure NFC driver’s firmware is available with CLO / CD functions.

Product Dimension

Wiring Diagram

  1. With DALI bus
  2. With PUSH dimmer

AC Push Function

  1. Click the button to switch ON/OFF
  2. Press and hold down the button to increase or decrease light intensity to desired level and release it, then repeat the operation to adjust light intensity to opposite direction. The dimming range is from 1% to 100%.

Operating window Dimming Curve Driver Performance Driver Performance

Expected Lifetime

Module Number Output current Ta 30 °C 40 °C 45 °C… 60 °C
SRPY-2305N-10CC100-500 100 – 500 mA Tc 50 °C 60 °C 70 °C… 85 °C
SRPY-2309N-10CCT100-500 100 – 500 mA Lifetime > 100,000 h > 80,000 h >
60,000 h > 40,000 h

The LED driver is designed for a lifetime stated above under reference conditions .
The relation of tc to ta temperature depends also on the luminaire design.
MCB Load Quantity Note:

  1. Those MCB parameters are based on ABB S200 series circuit breakers.
  2. For different brands and models of miniature circuit breakers, the quantity of drivers will have difference.
  3. Please do not exceed the above-mentioned quantity during on-site installation, and the specific load quantity shall be subject to on-site installation.
  4. When the installation environment temperature of MCBs exceeds 30°C or when multiple MCBs are installed side by side, the number of mounted drives will be reduced, which requires recalculation.
  5. Type C MCB’s are strongly recommended to use with LED lighting

Update log

Date Version Update content Update by
8/4/2023 V1.2 Update PF/THD/Eff/MCB Load/ Lifetime…. Romeo

Note: Subject to change without notice. Please contact us if you have any questions.