SUNRICHER SR-ZV9080A Z-Wave Curtain Motor Controller Instruction Manual

June 4, 2024
SUNRICHER

SR-ZV9080A Z-Wave Curtain Motor Controller
Instruction Manual

Z-Wave Curtain Motor Controller

Important: Read All Instructions Prior to Installation

Function introduction

SUNRICHER SR ZV9080A Z Wave Curtain Motor Controller -
function

Product Data

Z-Wave Frequency 868.42 MHZ (EU)/908.42 MHZ (US)/921.42 MHz (ANZ)
Input Voltage AC100-240V
Output Voltage AC100-240V
Max. Load Current Resistive loads:4A Capacitive/inductive loads:2A
Operating temperature 0 to 40°C
Relative humidity 8% to 80%
Dimensions 45.5x45x20.3mm

Safety & Warnings

  • DO NOT install with power applied to the device.
  • DO NOT expose the device to moisture.

Quick Start

How to install:

  • Step 1: power on the Z-Wave curtain motor controller.
  • Step 2: activate inclusion mode on your Z-Wave controller.
  • Step 3: activate the inclusion mode of the curtain motor controller by triple-pressing the network inclusion/exclusion button. The curtain motor controller will be included in the Z-Wave network.

Product Description

The curtain motor controller is a universal, Z-Wave Plus V2-compatible, electric motor controller. The device allows for controlling motors of roller blinds and Venetian blinds,  which are single-phase AC-powered. The curtain motor controller allows for precise positioning of roller blinds or Venetian blind slats. Precise positioning is available for the motors equipped with mechanic and electronic end switches. The device also allows for controlling the on/off of lights. The module may be controlled wirelessly, through the Z- Wave network primary controller, or through the switch keys connected to it. In addition, the curtain motor controller is equipped with Power Metering and over-current protection.
The curtain motor controller can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery-operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network.
If the user’s gateway also supports smart start, add the device by scanning the QR code, Smartstart allows users to quickly add devices to the gateway by scanning the device’s  QR code. After adding the device by scanning the QR code, waiting for a while, or resetting the power of the device, the device will be added to the gateway automatically. Please find the QR  code on the casing of the device.
The encryption mode that the curtain motor controller supports is S2 Unauthenticated. When the device is being included in a Z-Wave network, you can use your primary controller/gateway to enable encryption mode or disable encryption. (The primary controller/gateway shall support encryption mode configuration). The curtain motor controller supports OTA and can update firmware wirelessly.

Main Features:

  • Compatible with any Z-Wave or Z-Wave+ Controller,
  • Controlled by Sunricher EasyHome or any other Z-Wave controller,
  • Advanced microprocessor control
  • Active element: electromagnetic, micro-gap relay switch
  • The device may be operated by momentary or toggle switches, and by dedicated roller blind control switches
  • The connected motor’s current and historical power consumption measured
  • Over current protection
  • To be installed in wall switch boxes of dimensions allowing for installation, conforming to provisions of applicable regulations
  • The curtain motor controller supports OTA and can update firmware wirelessly

Installation Guide

Please read carefully the enclosed user manual before installation of the curtain motor controller, in order to ensure an error-free functioning.

ATTENTION: Prior to the assembly of the product, the voltage network has to be switched OFF and ensured against re-switching.

Inclusion (adding to a Z-Wave network)

  1. Set primary controller/gateway into inclusion mode (Please refer to your primary controller’s manual on how to turn your controller into inclusion).

  2. Power on the curtain motor controller and set it into inclusion mode. There are two methods to set the roller shutter into inclusion mode:
    1)Triple press the network inclusion/exclusion button, it will set the curtain motor controller into inclusion mode. 30 seconds timeout if there is no reply from the Z-Wave primary controller, repeat the operation.
    2)When the value of configuration parameter 8 is set as 1, triple press the switch connected to S1, and it will set the curtain motor controller into inclusion mode. 30 seconds timeout if there is no reply from the Z-Wave primary controller, repeat the operation.

  3. The curtain motor controller will be added to the Z-Wave network.

Exclusion (removing from a Z-Wave network)

  1. Set the primary controller/gateway into exclusion mode (Please refer to your primary controller’s manual on how to set your controller into exclusion).

  2. Power on the curtain motor controller and set it into exclusion mode. There are two methods to set the curtain motor controller into exclusion mode:
    1)Triple press the network inclusion/exclusion button, it will set the curtain motor controller into exclusion mode. 30 seconds timeout if there is no reply from the Z-Wave primary controller, repeat the operation.
    2)When the value of configuration parameter 8 is set as 1, triple press the switch connected to S1, it will set the curtain motor controller into exclusion mode. 30 seconds timeout if there is no reply from the Z-Wave primary controller, repeat the operation.

  3. The curtain motor controller will be removed from the Z-Wave network.

Factory Reset

Press and hold down the network inclusion/exclusion button for over 10 seconds, the curtain motor controller will be reset to factory defaults.

Configure Parameter 3 to Set Working Mode

  1. When the parameter 3 value is configured as 0, light mode: either S1 or S2 can control both Q1 and Q2, and short pressing or hold down will be recognized automatically. For detailed configuration please refer to configuration parameter 7.
    Note: when configured as light mode, root point, endpoint 1 mirrors to relay 1 (Q1), and endpoint 2 mirrors to relay 2 (Q2).

  2. When the parameter 3 value is configured as 1, shutter mode without positioning: S1 and S2 are only valid while held down. Hold down S1, relay 1 (Q1) ON, relay 2 (Q2) OFF.  Hold down S2, relay 2 (Q2) ON, relay 1 (Q1) OFF.
    If the command is sent by a gateway, it only supports upward on, downward off, and stop, it does not support positioning percentage operation.
    Nodes mirror function: root point, endpoint 1 with the same function: control shutter upward and downward actions. Endpoint 2 has no function.

  3. When the parameter 3 value is configured as 2, shutter mode with positioning: S1 and S2 are only valid while held down. Hold down S1, relay 1 (Q1) ON, relay 2 (Q2) OFF. Hold down S2, relay 2 (Q2) ON, relay 1 (Q1) OFF.
    When reaching any end’s positioning, both relays will be OFF. If the command is sent by a gateway, it supports positioning percentage operation. When the slat function of the shutter is enabled, a valid time should be set through the parameter 13, so that the slat rotation function can be supported.

Nodes mirror function: root point, endpoint 1 with the same function: control shutter upward and downward actions. Endpoint 2 controls the shutter’s slat, switch multilevel  set=50 means to open the slat to the maximum extent.

Note: the connected curtain motor should support position restriction function, i.e. endpoint awareness.

Positioning Calibration

Calibration is a process during which a curtain motor controller learns the position of the limit switches and a motor characteristic. Calibration is mandatory when the working mode of the curtain motor controller is Shutter mode with positioning. Connect the controller to the motor according to the wiring diagram, there are two calibration methods as  follows:

  1. Calibration through the calibration button, short press the button twice, and calibration start automatically, short press the button twice again, and calibration will stop.
  2. Set the configuration parameter 6 value to 1, calibration starts automatically.
    Note: after installing the curtain motor, first do position restriction setting according to its user manual, i.e. top end and bottom end, then use the curtain motor controller to do positioning calibration.

Scene Control
Users can configure scenes using the command class SCENE_ACTUATOR_CONF_SET, and activate the scenes using the command class SCENE_ACTIVATION_SET.

Activate Scenes Using Switch S1 S2
Users can configure configuration parameter 9 to decide whether to send a scene activation command using the command class CENTRAL_SCENE_NOTIFICATION.

The scene ID and key attribute supported by switches S1 and S2 are as follows:

Switch Number

| Support Action type| Scene ID|

Key Attribute

---|---|---|---

S1

| Short press once| 1| Key pressed once
Short press twice| 1| Key pressed twice
Short press 3 times| 1| Key pressed 3 times
Press and hold, release| 1| Key held down and released

S2

| Short press once| 2| Key pressed once
Short press twice| 2| Key pressed twice
Short press 3 times| 2| Key pressed 3 times
Press and hold, release| 2| Key held down and released

The default configuration of CENTRAL_SCENE_CONFIGURATION_SET is Slow Refresh = 1(send Key Held Down every 55s when the switch is pressed and held down).

Association

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events  (e.g. button pressed). In case the event happens all devices stored in the respective association group will receive a common wireless command.

Association Groups:
Root point

Association Groups

| Group Name| Max Nodes|

Description

---|---|---|---
Group 1| Lifeline| 5| 1.  When pressing and holding down the “K2” button for 10S to reset the device, send “Device Reset Locally Notification” to associated devices of this group to report factory reset information.
2.  When the overload is detected, send “NOTIFICATION_REPORT” to the associated devices of this group.
3.  Send METER_REPORT actively.
4.  When the action of S1 and S2 is detected, send CENTRAL_SCENE_NOTIFICATION.
5.  Send   SWITCH_MULTILEVEL_REPORT.

Endpoint 1

Association Groups

| Group Name| Max Nodes|

Description

---|---|---|---
Group 1| Lifeline| 0| SWITCH_MULTILEVEL_REPORT

Endpoint 2

Association Groups

| Group Name| Max Nodes|

Description

---|---|---|---
Group 1| Lifeline| 0| SWITCH_MULTILEVEL_REPORT

Curtain Control Commands Mirror Description

| Shutter mode with   positioning| Shutter mode without positioning
---|---|---
Basic Set (Value=0xFF)| Multilevel Switch Set (0xFF): Restore most recent(not 0) level| Multilevel Switch Set (0xFF): Open
Basic Set (Value=0x00)| Multilevel Switch Set (0x00): close| Multilevel Switch Set (0x00): Close
Basic Set (Value=0x01..0x63)| Multilevel Switch Set (0x01..0x63)| Multilevel Switch Set(0x01..0x63): Open
Basic Report (Current Value, Target Value, Duration)| Multilevel Switch Report (Current Value, Target Value, Duration)| Multilevel Switch Report (Current Value, Target Value, Duration)

Note: the Duration parameter of the Multilevel Switch Set is invalid.
Set and unset associations:
(Note: All association information will be cleared automatically once the curtain motor controller is excluded from a network.)
Set association by operating the primary controller/gateway to send packets to the curtain motor controller:
The primary controller/gateway sends packets to the curtain motor controller using
“COMMAND_CLASS_ASSOCIATION” or “COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION”.
Node Information Frame
The Node Information Frame is the business card of a Z-Wave device. It contains information about the device type and the technical capabilities. The inclusion and exclusion  of the device is confirmed by sending out a
Node Information Frame. Besides this, it may be needed for certain network operations to send out a Node Information Frame.
How to send out Node Information Frame:
When the curtain motor controller is set to inclusion/exclusion mode again, it will send out Node Information
Frame, there are 2 kinds of operation as follows:

  1. triple press the K2 button, and the curtain motor controller will be set to inclusion/exclusion mode, then send out
    Node Information Frame.

  2. When the curtain motor controller is under inclusion mode, there are two kinds of operation:

  1. Triple press the K2 button, and the curtain motor controller will be set to inclusion mode again, and send out Node
    Information Frame.
  2. Power off and power on the curtain motor controller, it will be set to inclusion mode automatically, and send out Node Information Frame.

Technical Data

Wireless Range up to 100 m outside, on average up to 40 m inside buildings
SDK 7.13.6.0
Explorer Frame Support Yes
Device Type Window Covering Position/Endpoint Aware
Generic Device Class GENERIC_TYPE_SWITCH_MULTILEVEL
Specific Device Class SPECIFIC_TYPE_CLASS_C_MOTOR_CONTROL
Role Type Always On Slave (AOS)

Endpoint 1 device type :
GENERIC_TYPE_SWITCH_MULTILEVEL/SPECIFIC_TYPE_CLASS_C_MOTOR_CONTROL
Endpoint 2 device type:
GENERIC_TYPE_SWITCH_MULTILEVEL/SPECIFIC_TYPE_CLASS_C_MOTOR_CONTROL
Note: the root point mirrored by endpoint 1 has the same function as endpoint

SUPPORTED COMMAND CLASS
Root Device Command-List

Node Info Support S2/S0
COMMAND CLASS ZWAVEPLUS INFO V2
COMMAND CLASS SECURITY V1
COMMAND CLASS SECURITY _2 V1
COMMAND CLASS TRANSPORT SERVICE V2
COMMAND CLASS SUPERVISION V1
COMMAND CLASS SWITCH MULTILEVEL V4
COMMAND CLASS ASSOCIATION V2
COMMAND CLASS ASSOCIATION GRP INFO V1
COMMAND CLASS VERSION V2
COMMAND CLASS MANUFACTURER SPECIFIC V2
COMMAND CLASS DEVICE RESET LOCALLY V1
COMMAND CLASS POWERLEVEL V1
COMMAND CLASS CONFIGURATION V1
COMMAND CLASS FIRMWARE UPDATE MD V4
COMMAND CLASS NOTIFICATION V8
COMMAND CLASS METER V3
COMMAND CLASS MULTI-CHANNEL V4
COMMAND CLASS MULTI CHANNEL ASSOCIATION V3
COMMAND CLASS SCENE ACTIVATION V1
COMMAND CLASS SCENE ACTUATOR CONF V1
COMMAND CLASS CENTRAL SCENE V3 V3
COMMAND CLASS WINDOW COVERING V1
COMMAND_CLASS_ZWAVEPLUS_INFO V2
COMMAND_CLASS_SECURITY_2 V1
COMMAND_CLASS_SECURITY V1
COMMAND_CLASS_SUPERVISION V1
COMMAND_CLASS_SWITCH_MULTILEVEL V4
COMMAND_CLASS_ASSOCIATION V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO V1
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION V3
COMMAND CLASS SCENE_ ACTIVATION V1
COMMAND CLASS SCENE ACTUATOR CONF V1
COMMAND_CLASS_WINDOW_COVERING V1

Endpoint 2 Command-List

Node Info

|

Support S2/S0

---|---
COMMAND_CLASS_ZWAVEPLUS_INFO| V2|
COMMAND_CLASS_SECURITY_2| V1|
COMMAND_CLASS_SECURITY| V1|
COMMAND_CLASS_SUPERVISION| V1|
| |
COMMAND_CLASS_SWITCH_MULTILEVEL| V4| YES
COMMAND_CLASS_ASSOCIATION| V2| YES
COMMAND_CLASS_ASSOCIATION_GRP_INFO| V1| YES
COMMAND_CLASS_MULTI_CHANNELASSOCIATION| V3| YES
COMMAND
CLASS SCENE ACTIVATION| V1| YES
COMMAND CLASS SCENE ACTUATOR CONF| V1| YES
COMMAND_CLASS_WINDOW_COVERING| V1| YES

Notification Report

Notification Type

|

Triggering Event

---|---
NOTIFICATION_TYPE_POWER_MANA

CEMENT(08)

| POWER_MANAGEMENTOVERCURRENT DETECTED(06)

Over Current Alarm: When connecting to a resistive load, the over-current value is 4.1A. When connecting to a motor or capacitive load, the over-current value is 2.1A. Over-current LED will flash 400ms   every 1 second, and relays will turn off.

Configuration Command Class

Parameter Size Description Default Value
Enable/disable the curtain motor controller to report the state change

percentage threshold (report only when the change value is at the specified percentage), if enabled, report when the value reaches both 0% and 99%. When the working mode is configured as tight mode, as long as the state changes, the state change percentage threshold will be reported. SWITCH_MULTILEVEL_REPORT
0: disable to report actively
1-10: value to report. unit is one percent| 5
0x03(3)| ‘| Working mode
0: light mode
1:Shutter mode without positioning
2:Shutter mode with positioning|
0x04(4)| 1| Enable/disable to save positioning percentage, record and save current positioning every time when the curtain moves to the specified position, if the working mode is configured as light mode, record the on/off state.
Ox00: disable Ox01: enable| i
Ox05(5)| 1| Enable/disable over current protection
0: disable
1: enable. when overcurrent is detected, there are two methods to cancel the alarm:
1. short press either switch button S1 or S2. the alarm will last at least 1 minute and then be canceled.
2. re-power on the curtain motor controller| 1
Ox06(6)| | Only value 1 can be written in, which means starting positioning calibration.
When read.
Ox01: positioning calibration completed
Ox00: positioning not calibrated
This parameter is only valid when parameter 3 is configured as shutter mode with positioning.| 0
| | When the parameter 3 value is configured as 0 (light mode), the configuration of button 51 and S2 control.
Value=0
Short press 51 to switch ON/OFF 01. Press and hold down 51 to switch ON 01, then release to switch OFF 01.
Short press S2 to switch ON/OFF 02. Press and hold down S2 to switch ON 02, then release to switch OFF 02.
Value=1
Short press 51 to switch ON/OFF 01. When S1 is pressed
and held down, then released. not processed.
Short press S2 to switch ON/OFF 02. When S2 pressed and held down, then released. not processed.
Value=2
Press and hold down S1 to switch ON 01, then release to switch OFF 01. When S1 short pressed, not processed. Press and hold down S2 to switch ON 02, then release to switch OFF 02. When S2 short pressed, not processed.
Value=3
Short press S1 or S2 to switch ON/OFF of both 01 and 02 simultaneously. When S1 or S2 is pressed and held down, not processed Value=4
Press and hold down S1 to switch ON Q1 and Q2. When S1
short pressed, not processed.
Press and hold down S2 to switch OFF Q1 and Q2. When
S2 short pressed, not processed.|
0x08(8)| 1| Enable/disable to add the device to or remove it from a ZWave network through button S1. Please refer to the parts of inclusion and exclusion for details.
0: enable
1: disable| 1
0x09(9)| 1| Enable/disable to send scene activation command CENTRAL_SCENE_NOTIFICATION_V3 when the switches S1 and S2 are pressed.
0: disable to send for the action of both S1 and S2
1: enable to send for the action of both S1 and S2
2: enable to send for the action of only S1
3: enable to send for the action of only S2| 1
0x0A(10)| 1| Power change absolute threshold report, unit is W
0: disable absolute threshold comparison function
1-100: the value of the power change absolute threshold, if
power change value is over the threshold value, report the
power change value using METER_REPORT| 10
0x0B(11)| 1| The current change absolute threshold, unit is 0.1A
0: disable absolute threshold comparison function
1-10: the value of the current change absolute threshold, if the current change value is  over the threshold value, report the current change value using METER_REPORT| 1
0x0C(12)| 1|  Voltage change absolute threshold, unit is 1V
0: disable absolute threshold comparison function
1-10: the value of the voltage change absolute threshold, if the voltage change value is over  the threshold value, report the voltage change value using METER_REPORT| 2
0x0d(13)| | Slats rotation time, the unit is 0.1S
0: disable the function
5-250 (0.5S-25S): value of the slats rotation time
This parameter is only valid when parameter 3 is configured as shutter mode with positioning.| 0
0x0E(14)| 4| Time cycle to report energy consumption value (unit is KWH), U, I, W actively
60-2678400 (31 days), value of the time cycle, unit is S.| 600 (1 hour)

Wiring Diagram
Notes for the diagrams:
L – terminal for live lead
N – terminal for neutral lead
S1 – terminal for switch key No. 1 (enable to set the device into inclusion/exclusion mode)
S2 – terminal for switch key No. 2
Q1 – output terminal no. 1 for electrical motor
Q2 – output terminal no. 2 for electrical motor
K1 – positioning calibration button when working mode is configured as shutter mode with positioning or Venetian mode (up/down and slats rotation)
K2 – inclusion/exclusion button (used to add or remove a device from the system)

Compatible Load Types

Supported load types 100-240V~
Lamp and resistive loads Max. 4A
Inductive loads Max. 2A
Capacitive loads Max. 2A

SUNRICHER SR ZV9080A Z Wave Curtain Motor Controller -
Diagram

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

SUNRICHER User Manuals

Related Manuals