Panasonic E2 Type Energy Saving High Fresh Air Ducted
Product Information
Specifications:
- Model Name: Indoor Unit / E2 Type
- Type: High Static Ducted
- Motor: DC motor
- Mode: Concealed duct / Air conditioning mode
- Self-diagnosing Function: Yes
- Automatic Fan Operation: Yes
- Dry Mode: Yes
- Automatic Restart Function: Yes
- Static Pressure Modes: 270 Pa / 140 Pa / 60(72*) Pa
- Max. Static Pressure Setting: 270 Pa
- Sensible Cooling Improvement: 5-10%
- Rap Valve Kit Requirement: No
- Discharge Air Temperature Control: Yes
- Optional Accessories: CZ-RTC6W, CZ-RTC6, CZ-RTC5B, CZ-RWS3, CZ-RWRC3
Product Usage Instructions
Installation:
The Indoor Unit / E2 Type is a high static ducted air conditioning unit
designed for exceptional installation flexibility. Follow the steps below to
install the unit:
- Select a suitable location for installation.
- Ensure the necessary power source is available (220/230/240 V, 1 phase – 50 Hz or 220/230 V, 1 phase – 60 Hz).
- Connect the required pipe connections for liquid and gas.
- Install the drain piping.
- Secure the unit using the provided suspension bolts.
- Make sure there is sufficient service space around the unit (800mm or more).
- Mount the optional accessories, if required.
Operation:
To operate the Indoor Unit / E2 Type, follow these steps:
- Make sure the unit is properly installed and connected to a power source.
- Use the remote controller (CZ-RTC6W, CZ-RTC6, CZ-RTC5B, CZ-RWS3, or CZ-RWRC3) to control the unit.
- Select the desired mode (cooling, heating, dry mode, etc.) using the remote controller.
- Adjust the fan speed and temperature settings as needed.
- The unit will automatically diagnose any issues and display error codes if necessary.
- In case of a power outage, the unit will automatically restart with the previous settings once power is restored.
FAQ:
- Q: What are the available static pressure modes for the Indoor Unit / E2 Type?
- A: The available static pressure modes are 270 Pa, 140 Pa, and 60(72*) Pa. You can select between these modes for extra installation flexibility.
- Q: What is the maximum static pressure setting for this unit?
- A: The maximum static pressure setting is 270 Pa. This enables the use of long ducts for installation in a wide range of spaces, making it ideal for large-scale offices, restaurants, and other facilities.
- Q: Does this unit require a Rap Valve Kit?
- A: No, thanks to improved performance, a Rap Valve Kit (CZ-P160RVK2) is no longer required for this unit.
- Q: How much improvement can be expected in sensible cooling?
- A: The new heat exchanger with a 7mm pipe increases the heat transfer surface, resulting in a 5-10% improvement in sensible cooling.
E2TYPE High Static Ducted
Concealed duct / Air conditioning mode
High static and large airflow ducted for exceptional installation
flexibility.
S-180ME2E5 / S-224ME2E5 / S-280ME2E5
Optional accessory
- CZ-RTC6W
- CZ-RTC6
- CZ-RTC5B
- CZ-RWS3 Remote controller
- CZ-RWRC3 Receiver
Technical focus
- Design flexibility thanks to high static pressure and large air volume
- DC motor equipped
- Power input 45% less (compared to E1 type)
- Discharge air temperature control to reduce cold drafts during heating operation
- Configurable air temperature control
- Available Fresh Air Intake mode (See page 80-81
FEATURES
3-step static pressure set up
You can select between the three Static Pressure modes of 270 Pa/140
Pa/60(72*) Pa for extra installation flexibility.
Max. 270 Pa static pressure setting
A maximum static pressure setting of a high 270 Pa enables the use of long
ducts for installation in a wide range of spaces. Ideal for large-scale
offices, restaurants and other facilities.
Sensible cooling 5-10% improved
New heat exchanger with φ7mm pipe that increases the heat transfer surface
to improve sensible cooling (5-10% improvement)
No Rap Valve Kit required
Thanks to improved performance, a Rap Valve Kit (CZ-P160RVK2) is no longer
required.
Discharge air temperature control
- Equipped with 4 sensors (Intake/ Discharge)
- Able to control discharge air temperature for accurate room temperature control.
- Possible to reduce cold drafts during heating operation.
E2 TYPE HIGH STATIC DUCTED Dimensions
- Refrigerant piping (liquid pipes) Ø9.52
- Refrigerant piping (gas pipes) 180 & 224 type: Ø19.05, 280 type: Ø22.22
- Power supply outlet (Ø25 grommet, rubber)
- Power supply outlet (spare) (Ø30 knock-out)
- Optional outlet for piping
- Drain port 25 A, male thread
- Duct connection for suction
- Duct connection for discharge
E2TYPE Energy Saving High Fresh Air Ducted
Concealed duct high-static pressure
High static and large airflow ducted for exceptional installation
flexibility
S-224ME2E5 / S-280ME2E5
Optional accessory
- CZ-RTC6W
- CZ-RTC6
- CZ-RTC5B
- CZ-RWS3 Remote controller
- CZ-RWRC3 Receiver
Technical focus
- 100% fresh air intake for ventilation purpose
- Design flexibility with high static pressure and large air volume
- DC motor equipped
- Power input 45% less (compared to H1 type)
- Discharge air temperature control to reduce cold drafts during heating operation
- Configurable air temperature control
High Fresh System
High Fresh System enables delivery of fresh outside air at almost the same
temperature and humidity as indoor air without putting a burden on air
conditioning.
- Capable of treating outdoor air only. Indoor air conditioner units are required to adjust indoor air temperature.
Mix operation unit with standard indoor units
Possible to combine High Fresh Air ducted indoor unit and standard air
ducted indoor units. When other indoor units are connected in same circuit,
keep following capacity ratio. E2 type/Outdoor unit < 30%, and Total of
indoors(incl. E2)/outdoor <100%
Discharge air temperature control
- Equipped with 4 sensors (Intake/ Discharge)
- Able to control discharge air temperature for accurate room temperature control.
- Possible to reduce cold drafts during heating operation.
Remark For High Static Ducted Series
Model Name | S-224ME2E5 | S-280ME2E5 |
---|---|---|
Power source | 220/230/240 V, 1 phase – 50 Hz, 220/230 V, 1 phase – 60 Hz |
Cooling capacity
| kW| 22.4| 28.0
BTU/h| 76,400| 95,500
Heating capacity
| kW| 21.2| 26.5
BTU/h| 72,300| 90,400
Power input
| Cooling| kW| 0.290| 0.350
Heating| kW| 0.290| 0.350
Running current| Cooling| A| 1.90/1.85/1.80| 2.30/2.20/2.10
Heating| A| 1.90/1.85/1.80| 2.30/2.20/2.10
Fan
| Type| Sirocco fan| Sirocco fan
Air flow rate
| m³/h| 1,700| 2,100
L/s| 472| 583
Motor output| kW| 0.560 x 2| 0.750 x 2
External static pressure| Pa| 200| 200
Sound power level| dB| 75| 76
Sound pressure level| dB(A)| 43| 44
Dimensions H x W x D| mm| 479 x 1,453 x 1,205| 479 x 1,453 x 1,205
Pipe connections
| Liquid| inches (mm)| Ø9.52 (Ø3/8)| Ø9.52 (Ø3/8)
Gas| inches (mm)| Ø19.05 (Ø3/4)| Ø22.22 (Ø7/8)
Drain piping| VP-25| VP-25
Net weight| kg| 102| 106
GLOBAL REMARKS
Rated conditions: | Cooling | Heating |
---|---|---|
Outdoor air temperature | 33˚C DB / 28˚C WB | 0˚C DB / -2.9˚C WB |
E2 TYPE HIGH STATIC DUCTED Dimensions
- Refrigerant piping (liquid pipes) Ø9.52
- Refrigerant piping (gas pipes) 4 type: Ø19.05, 280 type: Ø22.22
- Power supply outlet (Ø25 grommet, rubber)
- Power supply outlet (spare) (Ø30 knock-out)
- Optional outlet for piping
- Drain port 25 A, male thread
- Duct connection for suction
- Duct connection for discharge