Uplink Paradox Digiplex EVO HD Programming the Panel Instruction Manual

June 17, 2024
Uplink

Paradox Digiplex EVO HD
Wiring Uplink’s Cellular Communicators
and Programming the Panel

Paradox Digiplex EVO HD Programming the Panel

CAUTION:

  • It is advised that an experienced alarm installer programs the panel as further programming may be required to ensure proper performance and use of the full functionality.
  • Do not route any wiring over circuit board.
  • Full panel testing, and signal confirmation, must be completed by the installer.

NEW FEATURE: For Uplink Series Communicators, the status of the panel can be retrieved not only from the status PGM but now also from the Open/Close reports from the dialler. Therefore, wiring the white wire and programming of the status PGM of the panel is optional.

IMPORTANT NOTE: The Open/Close reporting needs to be enabled during the initial pairing procedure.

Wiring the Uplink communicators to Paradox Digiplex EVO HD

Uplink Paradox Digiplex EVO HD Programming the Panel - Wiring the Uplink
communicators

Wiring and Programming Uplink Communicators to Paradox Digiplex EVO HD

Programming the Paradox Digiplex EVO HD Alarm Panel via the Keypad

Enable Contact ID reporting:

Display Keypad Entry Action Description
Date & Time 0, 000000 Hold 0 to go to Installer code, 000000 to go to

Programming menu.
Section| 3035| To go to System Options menu.
3035 Options| 6, Enter| 6 must be OFF (account number transition for partition number), Enter.
3036| 1,2,| 1 and 2 must be OFF – disable phone line monitoring.
| 3,4| 3 and 4 must be ON – (3 is dialer Enabled, 4 Dialer method – tone).
3037| Enter, Clear| To save and go back to main menu.
Section| 3061| To go to account number for Partition 1.
3061 Communicator| 1234| Enter desired account number.
3062| Clear| To go to main menu.
Section| 3070| To go to reporting formats.
3070 Communicator| 5555| To select Ademco ContactID for all lines.
3071 Telephone| 123456 Enter| Enter actual of imaginary phone number to report to, Enter to save.
3072 Telephone| Clear| To go to main menu.
Section| 4031| To reset all reporting codes to FF (Default).
Section| Clear| Press Clear to exit programming mode.

Enable keyswitch arm/disarm and status output:

Display Keypad Entry Action Description
Date & Time 0, 000000 Hold 0 to go to Installer code, 000000 to go to

Programming menu.
Section| 0001| To enter zone programming.
0001 Serial/Input| 0, Enter,| 0 and Enter to remove if there is a serial number and save it.
| Clear, Clear| To go to main menu.
Section| 0101| To go to zone parameters.
0101 Parameters| 01, Enter| 0 to choose disable zone type for Zone 1, 1 to Assign Zone 1 to Partition 1.
0102 Parameters| Clear, Clear| To go to main menu.
Section| 0501| To go to keyswitch numbering.
0501 Serial/Input| 8 digit No. 001| Type again the 8 digit serial number of the panel, 001 to select input 1.
0502 Serial/Input| Clear, Clear| To go to main menu.
Section| 0601| To go to keyswitch parameters.
0601 Parameters| 11, Enter, Clear| 1 to assign keyswitch zone to partition 1, 1 to choose Momentary Keyswitch, Enter to save, Clear to go back to main menu.
Section| 3033| To go to System Options 3.
3033 Options| 7 on, 8 0ff, Enter, Clear| 7 must be ON (EOL resistor on hardwired zones), 8 must be OFF (disable ATZ zone doubling), Enter to save, Clear, Clear to go back to main menu.
Section| 0901| To go to PGM Activation programming.

Wiring and Programming Uplink Communicators to Paradox Digiplex EVO HD

0901 Serial/Input| 8 digit No. 001| Type again the 8 digit serial number of the panel, 001 to select input 1.
---|---|---
0901 Timers| 064| To select event group “Status 1”.
0901 Timers| 255| To select “Armed” for all zones.
0901 Timers| 000| To disable PGM activation start timer.
0901 Timers| 000| To disable PGM activation end timer.
0901 Timers| 014| To disarm with user code.
0901 Timers| 000| To select Feature Group.
0901 Timers| 000| To disable PGM deactivation start timer.
0901 Timers| 000, 000| To disable PGM deactivation end timer.
Toggle options| 1 off,| 1 must be OFF for the PGM to be activated by deactivation event.
| 4 off| 4 must be OFF for the PGM initial state to be normally open.
| Enter, Enter,|
| Clear, Clear|

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Uplink User Manuals

Related Manuals