Eltako EUD12NPN Universal Dimmer Switch Instruction Manual
- June 17, 2024
- Eltako
Table of Contents
- Eltako EUD12NPN Universal Dimmer Switch
- Product Information
- Product Usage Instructions
- Temperature at mounting location: -20°C up to +50°C.
- Function rotary switch
- Typical connection
- Technical data
- Frequently Asked Questions (FAQ)
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Eltako EUD12NPN Universal Dimmer Switch
Product Information
Specifications
- Model: EUD12NPN/110-240V
- Input Voltage: 110-240V
- Type: Universal Dimmer Switch
- Part Number: 21 100 808 – 1
Product Usage Instructions
Installation
- Ensure the power is switched off before installation.
- Consult a skilled electrician to install the dimmer switch to avoid the risk of fire or electric shock.
- Follow the manufacturer’s installation guidelines provided in the user manual.
Operation
- Once installed, turn on the power and test the dimmer switch functionality.
- Adjust the dimmer switch to control the brightness of the connected light fixture.
- Refer to the user manual for specific instructions on setting up and using the dimmer switch.
Maintenance
- Regularly check the dimmer switch for any signs of wear or damage.
- If any issues are detected, disconnect power and consult a professional for repairs or replacement.
Only skilled electricians may install this electrical equipment otherwise there is the risk of fi re or electric shock!
Temperature at mounting location: -20°C up to +50°C.
Storage temperature: -25°C up to +70°C. Relative humidity: annual average value <75%.
Universal dimmer switch. Power MOSFET up to 400 W. Automatic lamp detection.
Standby loss 0.2 watt only. With adjustable minimum or maximum brightness and
dimming speed. With switching operation for children‘s rooms and snooze
function. Modular device for DIN EN 60715 TH35 rail mounting. 1 module = 18 mm
wide, 58 mm deep. Universal dimmer switch for lamps up to 400 watts, depending
on ventilation conditions. Dimmable 230 V LED lamps and dimmable energy saving
lamps ESL dependent on the lamps electronics and the dimming technology. Zero
passage switching with soft start and soft OFF to protect lamps.
Control and switching voltage 110 V AC to 240 V AC 50/60 Hz.
No minimum load required.
Short-time control commands switch on/off, permanent control varies the
brightness to the maximum level. An interruption of control changes the
direction of dimming. In case of a power failure the switching position and
the brightness level are stored. If applicable the dimmer will be switched on
at the stored brightness level after the supply voltage is recovered.
Automatic electronic overload protection and over-temperature switch-off.
Function rotary switch
The LED below the rotary switch on the front shows control commands. It starts
blinking after 15 seconds if a pushbutton is inhibited. During operation, the
upper rotary switch determines whether the automatic lamp recognition ‘AUTO’
should be active, or one of the special comfort positions LC1, LC2 or LC3.
If the MEM+ setting range is selected, the memory function is active and the
last bright-ness level set is saved when the device is switched off. If the
setting range MEM- is selected, the memory function is switched off and it is
always switched on with maximum brightness. Dimmable energy-saving lamps must
be operated on AUTO and MEM.
AUTO allows the dimming of all light species.
LC1 is a comfortable position for dimmable 230 V LED lamps which are not being
dimmed down enough when set to AUTO (trailing phase angle) dependent on the
construction and must therefore be forced to leading phase angle. LC2 and LC3
are comfort positions for dimmable 230 V LED lamps like LC1 but with different
dimming curves.
In positions, LC1, LC2, and LC3 no inductive (wound) transformers should be
used. In addition, the maximum number of dimmable LED lamps can be lower
than in the AUTO position dependent on the construction. The minimum
brightness level (completely dimmed down) or the maximum brightness level
(completely dimmed up) is adjustable with the middle % rotary switch.
The dimming speed can be adjusted with the lower dimming speed rotary switch.
The duration of soft start and soft OFF is changed simultaneously.
With special switching operation for children’s rooms: If the light is
switched on by holding down the pushbutton, it starts at the lowest brightness
level after approx. 1 second and dims up slowly as long as the pushbutton is
held down without modifying the last stored brightness level.
Snooze function: With a double impulse the lighting is dimmed down from
the current dimming position to the minimum brightness level and switched off.
The current dimming position as well as the adjustable minimum brightness
level determine the dimming time (max. = 60 minutes) which can be reduced as
required. It can be switched off at any time by short-time control commands
during the lighting is dimmed down. Holding down the pushbutton during the
dimming down process dims up and stops the snooze function.
Mixing of L loads (inductive loads, e.g. wound transformers) and C loads
(capacitive loads, e.g. electronic transformers) is not permitted. R loads
(ohmic loads, e.g. 230 V incandescent lamps and halogen lamps) may be added
anytime.
Mixing of L loads and C loads is possible with the dimmer switch EUD12D
in connection with capacity enhancer LUD12.
Typical connection
Technical data
- Applies to lamps of max. 150 W.
- Per dimmer it is only allowed to use max. 2 inductive (wound) transformers of the same type, furthermore, no-load operation on the secondary part is not permitted. The dimmer might be destroyed. Therefore do not permit load breaking on the secondary part. Operation in parallel of inductive (wound) and capacitive (electronic) transformers is not permitted!
- When calculating the load a loss of 20% for inductive (wound) transformers and a loss of 5% for capacitive (electronic) transformers must be considered in addition to the lamp load.
- Affects the max. switching capacity.
- Usually applies for dimmable energy-saving lamps and dimmable 230 V LED lamps. Due to differences in the lamp’s electronics, there may be limited dimming range, switch on and off problems dependent on the manufacturer, and a restriction on the maximum number of lamps; especially if the connected load is very low (for 5 W-LEDs). The comfort positions LC1, LC2, and LC3 optimize the dimming range, which, however, only gives a maximum power of up to 100 W. No inductive (wound) transformers may be dimmed in these comfort positions.
- At a load of more than 200 W ventilation clearance of ½ module to adjacent devices must be maintained.
The strain relief clamps of the terminals must be closed, which means the screws must be tightened for testing the function of the device. The terminals are open ex works.
Manuals and documents in further languages:
https://eltako.com/redirect/EUD12NPN*110-240V
ELTAKO GmbH
D-70736 Fellbach
Technical Support English:
+49 711 94350025
Frequently Asked Questions (FAQ)
Q: Can I install the dimmer switch myself?
A: Only skilled electricians should install the dimmer switch to prevent the risk of fire or electric shock.
Q: What should I do if the dimmer switch malfunctions?
A: If you encounter any issues with the dimmer switch, immediately disconnect power and seek assistance from a professional electrician for repairs or replacement.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>