SINIELE SWING GATE OPENER
User Manual
SGS Single Swig Gate Opener
Note:
- Please read and follow all warnings, precautions and instructions before installation and use.
- 2*12V batteries and 20W solar panel are not included.
- Regular machine inspections are required to ensure safety.
- Save this user manual.
Dear users
Thank you for choosing this product. Please read the manual carefully before
assembling and using it. Please do not leave out the manual if you send this
product to a third party.
Safety Instruction
- Please read this manual carefully before installation, in which involves with important information about installation. using. maintenance and safety.
- Any undefined operations under this manual is not allowed, incorrect using may damage the product even causing the injuries or property losses.
- To consider the possible danger during the installation or using process of swing gate operator, installation must strictly comply with the construction standard and electrical operating procedure.
- Before installation, please make sure that the power voltage being used matches with the supply voltage of this product. Please check if the leakage protection switch is installed and the grounding system is correct.
- Please check if additional equipment or materials are required to meet the specific requirements.
- The disposal of packaging material must be complying with the local regulation.
- Please do not change any parts except for those defined under this manual. Any undefined changes may cause the malfunction. Any damages to the product arising therefrom shall be beyond the liability of the company.
- Please do not leak water or any liquid into the controller or any other open devices. Please disconnect the power immediately if any mentioned cases happened.
- Please keep this product away from heat and open fire. Or it may damage the components; cause the failure or other hazards.
- Please make sure there is no vehicles. passengers and objects passing through while the swing gate is moving.
- Anti-clip equipment like infrared protection switch must be installed to avoid injuries to person and property losses. The company shall not be liable for any damage or accident arising therefrom.
- The installation. using and maintenance of this product must be carried out by professionals.
- Children are not allowed be touch the control devices or remote transmitters.
- A warning sign must be placed somewhere on the swing gate according to the national standard.
- Please keep this instruction properly for future reference.
Packing List
2.1 Machine Section
No | Picture | Name | Quantity |
---|---|---|---|
1 | Main Machine | 1 | |
2 | Control Box | 1 | |
3 | Manual Release Key | 2 | |
4 | Remote Control | 2 | |
5 | Wall Bracket | 2 | |
6 | Front Mounting Bracket | 1 | |
7 | Post Pivot Bracket | 1 | |
8 | (M8X25) Screw | 2 | |
9 | (M8X70) Screw | 4 | |
10 | (M10X200) Screw | 4 | |
11 | Mounting Screw (Short) | 1 | |
12 | (M8) Self-locking Nut | 9 | |
(M10) Self-locking Nut | 4 | ||
13 | (p8) Flat Washers | 6 | |
(p10) Flat Washers | 4 | ||
14 | Limit Stopper | 1 | |
15 | (8%x40) Clevis Pin | 1 | |
16 | (2.5) Cotter Pin | 1 | |
17 | U-shaped Mounting parts | 2 | |
18 | Self-Drilling Screws | ||
with Bonded Washers (6.3×25) | 2 | ||
19 | Infrared Sensor | 2 | |
20 | Warning Sign | 1 | |
21 | Battery box | ||
(Batteries not included) | 1 | ||
22 | Equipment connection line | 2 |
2.2 Solar Panel Section (Optional)
No | Picture | Name | Quantity |
---|---|---|---|
1 | (∅28)Solar bracket | 1 | |
2 | (∅32 )Solar bracket | 1 | |
3 | U-shaped clamps | ||
(Fixed solar bracket) | 4 | ||
4 | (20W) Solar panel | 1 | |
5 | (M6x20) Bolts | 1 | |
6 | (M4x10) Bolts | 8 | |
7 | (φ4)Washers | 8 | |
8 | (M4) Nuts | 8 | |
9 | (φ4)Washers | 8 |
Technical Parameters
Model | MS-2 |
---|---|
Power supply | 110V/60Hz |
Motor power | 50W |
Gate moving speed | 18∼22s/ 90° |
Max.single-leaf weight | 661 Pounds |
Max.single-leaf length | 12FT |
Max.force | 2600N |
Max.piston stroke | 12inches |
Remote control distance | ≥98FT |
Remote control mode | Single/Four button mode |
Storage battery (optional) | DC24V(4.5Ah or 9Ah) |
Noise | ≤58dB |
Recording of up remote controls | 32 pcs |
Remote frequency | 433.92 MHz |
Working temperature | -4°F∼+158°F |
Tools Needed for Standard Installation
Note: the cables must be suitable for outdoor use.
Cable List
| Cable Application| Cable Material| Max. Length
---|---|---|---
1| Cable of control box’s power supply| 3×2.5mm² (>30m)
3×1.5mm² (<30m)| Unlimited
2| Cable of gate opener’s power supply| 2×1.5mm²| 15m
3| Cable of infrared sensor| 2×0.5mm²| 10m
4| Cable of alarm lamp| 2×0.5mm²| 10m
5| Cable of electric lock| 2×0.5mm²| 10m
6| Extension cable of storage battery| 2×1.5mm²| 10m
7| Cable of solar power| 2×1.5mm²| 10m
- Due to different installation environments, installer need to prepare power cables for control box and for gate openers.
Note: cable outlet should be downward to prevent rainwater from entering wire along the cable.
Installation Drawing
Direction of Gate Opening
Gently move each gate leaf and operator through their full range of motion by hand, adjusting the positions of all the bolts and brackets as needed. Remember to ensure at least 1 in. (2.5cm) of clearance between the widest part of each operator and the gate throughout the path.The exact movement of the gate will depend on whether you are using a PLO or PSO setup, the exact distance from the base to the outer pivot hole (B), and the exact distance from the outer pivot hole to the centerline of your gate (A). The combination of these factors will determine the maximum open position of your gate as shown in the charts below.
7.1 Gate Opens Inwards
7.2 Gate Opens Outwards
Installation Steps
8.1 Preparation Before Main Machine Installation
- a) Before installing the gate opener, please confirm that the gates were installed correctly, please ensure that the gate can be manually operated smoothly, and the gate safety stopper can effectively prevent the gate to continue moving.
- b) Please keep a distance of 45-50mm between the gate bottom and the ground for installing the electric lock. If electric lock is not required, the distance between the gate bottom and the ground should be >20mm;
- c) The recommended mounting height of the 2 main machines is around 300 ~ 800mm above the ground, and make sure there are reliable fixed points for mounting brackets.
8.1.1 Cable Bury
In order to ensure the normal operation of the gate opener and protect the
cable from damage, please use two PVC pipes to bury the motor and power
cables, and the control cables separately. One PVC pipe for motor and power
cables, the other one for control cables.
8.1.2 Mounting Brackets Fixing
- To use the provided hardware, drill holes 10.5 mm across straight through your support post. You can start by drilling the holes for the bottom base bracket first to get more exact placement for the other holes. Use the M10x200 bolts, their M10 washers, and M10 nuts (l) as shown to secure
- the base brackets. If you install the top bracket at this point, remember to leave just enough room between the two brackets for the pivot bracket that will need to be held securely between them
8.2 Accessory Installation
A) Before installing the main machines, please install the wall bracket on the
wall first, then fix the connecting bracket, finally install the front
mounting bracket on the gate.
Note: Please detect by gradienter before fixing to ensure that the front
mounting bracket and the connecting bracket are in the same level.
Connect the connecting bracket and two wall brackets, please refer to Figure
4. B) The connecting bracket and the wall bracket can be connected
according to different conditions, please refer to figure 5. C)
Before the installation, please unlock the two main machines. Unlock method:
Open the manual release cover, insert the manual release key, rotate the key
until it’s released, as shown in Figure 6, then turn the telescopic arm,
you’ll find it’s stretched by hand easily. D)Connect the main machine with
connecting brackets by screw and nut as shown in Figure 7. E)As shown in figure 8 below, connect wall bracket with wall
according to marked position. Then, connect main machine with wall bracket by
screw and nut. (Please use spirit level to make sure the installation
levelness.)
8.3 Dimension of Control Box
Note
- To ensure safety and protect the machines, please install a gate stopper at the open limit position when the gate opens outward to prevent the gate from running over its travel. Meanwhile, to enable the 2 swings to close to its accurate limit position, please install a limit stopper at the closed limit position (as shown in figure 3). Similarly, when the gate opens inward, please install a limit stopper at the closed limit position (as shown in figure 2).
- Before installing the main machine, please make sure the main machine and components are in good mechanical performance and the gate can be manually operated flexibly.
- One control unit can optionally drive one main machine or two main machines.
- Earth leakage circuit breaker must be installed on where the gate movement can be seen, and the minimum mounting height for the control box should be over 1.5m to avoid being touched by kids.
- After installation, please check whether the mechanical property is good or not, whether gate movement is flexible or not after unlocking, and whether the infrared sensor (optional) is installed correctly and effectively.
Wiring and Debugging
9.1 Installation of solar panel a) Insert the small round tube into
the large round tube and tighten it with M6x20 screw;
b) Fix the solar bracket to the solar panel with M4x10 screws and U-shaped
clamps; c) Pre draw holes on the wall and instal the solar
bracket on the wall;
d)
Fix the solar bracket to the wall or embed it underground with screws and
U-shaped clamps;
9.2 Installation of solar panel wiring
Note: The following operations must be carried out by professional
technicians and qualified electricians ![Moonshan SGS Single Swig Gate Opener
- Picture 47](https://manuals.plus/wp-content/uploads/2023/12/Moonshan-SGS- Single-Swig-Gate-Opener-Picture-47.jpg)a) Open the sliding cover on the back of the solar panel b) Use a screwdriver to connect the red wire to the positive and black wire to the negative, tighten the screw and slide the cover upwards.
9.3 Installation of batteries (Batteries are notincluded)
9.4 Installation of battery box wiring a) Insert the quick connect cable
into the corresponding port to complete the connection of the solar panel,
charger, battery, controller, and machine.
Attention: To connect an external 12V/24V battery, adjust the VOLTAGE pin
on the host controller to the corresponding 12V/24V position.
9.5 Q &A
Q1. Why does the controller not display charging effect when | connect the solar panel?
A1: Please carefully check if the wires of the solar panel are correct and not reversed. The voltage of the photovoltaic system should be higher than the voltage of the battery, and any sewage or shadow on the photovoltaic system will cause a voltage drop. Under normal circumstances, please use 18V photovoltaic to charge the 12V battery.
Q2. Why is my charging current very low?
A2: Using more solar panels and stronger sunlight will increase the charging current, otherwise using incorrect voltage or shadows on sewage and photovoltaics will reduce the charging current. When the battery voltage is high, entering floating charging mode will also reduce the charging current.
Q3. Why does the machine not work?
A3: It may be the wrong working mode, or it may be due to insufficient battery capacity or low voltage disconnection, or your machine is damaged. Please check these aspects, and you can directly connect your power supply (pay attention to the voltage value) to see if it is working. Please carefully check the wires.
Q4. The stored solar energy is not sufficient to supply the machine for use.
A4: If the electricity generated by the solar panel is lower than the electricity used by the machine, the machine will have to obtain electricity from the battery and solar energy, which will ultimately cause damage at some point. Please use more solar panels and increase battery capacity to prevent low power on cloudy or rainy days, or you can reduce the additional power consumption or working time of the machine to balance the system.
Q5. Why does my battery quickly run out of charge after being fully charged?
A5: Your battery can be used for a long time, and after hundreds of cycles, it has reached its limit. A depleted battery has no capacity to maintain its charge. Do a simple test, when you charge the battery, the voltage will rise quickly, and when you discharge again, the voltage will drop quickly, which means you should replace the battery.
9.6 Introduction to the controller
9.6.1 The Ports of the Controller
9.6.2 Control Board Drawing and Instructions
Terminal | Description |
---|---|
1. AC24VIN | 24VAC Power Supply Input |
2. +SOLAR- | Solar Power Input |
3. +BATT- | 24V Battery Input |
4. FORCE | Resistance Force |
5. SLOW DOWN | Slow Stop Distance |
6. SPEED | Moving Speed |
7. MOTOR1 | Motorl Output |
8. MOTOR2 | Motor2 Output (Single gate opener does not require connection) |
9. -ELOCK+ | Electric Lock Output |
10. -BLK+ | Alarm Lamp Output (Note: pay attention to the negative and |
positive.)
11. +24V| 24V Output Positive
12. +12V| 12V Output Positive (No output under dormant state)
13. EM1| Motorl Hall Sensor Power Output
14. LM1| Motorl Hall Sensor Limit Signal Input
15. EM2| Motor2 Hall Sensor Power Output
16. LM2| Motor2 Hall Sensor Limit Signal Input
17. PH| Photo Sensor Input Active
18. PED| Single Gate/Pedestrian Mode Input Active
19. OSC| Single Channel Input Active
20. ANT| Antenna
21. COM| Common
22. SIG| The signal is normally closed only after the door is in place
9.6.3 Infrared Sensors (“Photo Sensors”) Wiring Instructions As shown
above, connect the sensors’ common (COM) and return or neutral pins (V-) to
the COM pin on the board’s X5 terminal. Connect the receiver’s normally closed
(NC) pin to the PH pin on the same terminal.
Connect the power input pins (V+) on each sensor to the 24V power supply pin
(+24V) on the board’s X4 terminal. Remove any other wire connecting any of
these pins directly, but save any such wire in a safe place in case you ever
need to use the operator(s) without the photocells.
9.6.4 WIFI Module Wiring Instructions
9.7 Digital Screen Setting
When the control board is working, the users can check working state of gate
opener by digital screen on the control board.
9.8 Travel Setting (Very Imiportent)
In the first installation of gate openers, the installer need to set open
and closed limit switch positions for running the travel.
9.8.1 Learn the journey in the distress limit mode
Open both sides of the gate and lock the clutch, and then press and hold the
“+” button on the control board until the digital screen shows “SU”. After
this step, the gate will firstly run towards the closing direction and stop,
and then the gate will automatically open. When the two swing gates are fully
open, the gates will automatically close for the second time, and the travel
setting will be completed when the gates are closed. If the distance of
starting slow speed of gate is not appropriate, adjust the “SLOW DOWN ” button
to revise the distance.
Note:
- Wiring: the black wire of main engine 1 is connected to the left side of MOTOR1; The brown cable of host 1 connects to the right side of MOTOR1.The black cable of main engine 2 connects to the left side of MOTOR2; The brown cable of main engine 2 connects to the right side of MOTOR2.
- In single-door mode,the host connects to MOTORT.
- If the gate suddenly stops during travel setting, please increase the resistance force.
- If the gate didn’t stop when meets the obstacles during travel setting, please appropriately reduce the resistance force.
- Installer must redo travel setting after modifying the “SPEED” trimmer.
9.9 Trimmers Setting
a) Obstacle Sensibility Trimmer
To adjust the sensitivity of obstacle — clockwise to increase,
counterclockwise to reduce the sensitivity of obstacle. If there are
environmental effects, such as heavy winds, adjust the trimmer according to
environment.
b) Slow Speed Distance Trimmer
To adjust slow speed distance — clockwise to increase, counterclockwise to
decrease slow speed distance. Please do not set very short slow speed
distance, to avoid the gate collision.
c) Gate Moving Speed Trimmer
To adjust gate moving speed — clockwise to accelerate, counterclockwise to
slow down. The trimmer can be adjusted to change the opening and closing
travel time. This adjustment must be finished before travel setting.
9.10 Learning Remote Control & Delete Remote Control
9.10.1 Learning Remote Control
Press and hold “-” button, the alarm light will keep flashing, and digital
screen displays remote control mode — “PO” — two swing gates single channel
mode; “Pd” — single gate four channel mode; Press the button of the remote
control to be learned, the digital screen will show the number of current
learned remote control, then the remote control learning is completed. (The
default of new paired remote control is two swing gates single channel mode).
9.10.2 Delete Remote Control
Enter into “AE” in the digital screen and then to choose “rE” to delete the
remote controls.
9.10.3 Special Remote Control Key-button
Press and hold the combination keys for 5S.
C(stop)+D(single gate) combination key — enter into remote control learning.
Control Board Settings
10.1 Base Menu
- Press “PROG” to enter into base menu; Digital screen shows “NE”, select other functions of this menu by “+” and “-” buttons.
- Press “SET” to confirm or to enter into sub-menu; To exit menu, press “PROG”.
- If no command for one minute, the menu will automatically exit.
10.2 Base Menu Instruction
Menu
Press “PROG” to enter into base menu| Option
Press “+”(up) or “-“(down) to select;
Press “SET” to confirm.| Default/Attention
---|---|---
Working Mode| Standard mode;
0/C/S (Open/Close/Stop).
O/S/C standard mode with automatic closing function. When the gate opens, it
will automatically close after automatic closing time. If a “close the gate”
command is sent during the automatic closing time waiting time, the automatic
closing function will be canceled.
External three keys
(open/close/stop)
External three keys o/p/s
(Automatic closing with)
Community mode(with automatic closing function). When the gate opens, any gate
command will not be responded until it closes automatically. If user sends
gate command during the closing process, then the gate will reopen. If a gate
command is sent during the automatic closing waiting time, this waiting time
will be recalculated. If the gate is not closed completely for more than ten
consecutive times, the automatic closing function will be canceled and the
gate will be closed by re-sending the gate closing command. Note thatin
community mode, the gate still has the automatic closing function in case of
meeting obstacles.| Standard mode;
0/C/S
(Open/Close/Stop).
Single Gate/Dual Gates Switch| Dual gates mode(default).
Single gate mode.| Dual gates mode.
Open Gate Time Interval| 00-10: Open gate time interval is 0-15
seconds(default 3 seconds). If the interval shorter than 2 seconds, then the
electric lock cannot be used.| 3 seconds.
Automatic Closing Time| Automatic closing time can be set as 15(default), 30,
60, 90 seconds.| 15 seconds.
Remote Control Mode| Dual gates single channel mode.
Four channel mode.
Single gate single channel mode.
Delete all paired remote controls.| Dual gates single channel mode.
Low consumption mode| Low consumption mode on (When there is no operation in
the initial screen, the control board will automatically enter the low-
consumption mode after 1 minute.)
Low consumption mode off| Low consumption mode on
10.3 Advanced Menu
- Long press “PROG” 2 seconds to enter into advanced menu.
- Digital Screen shows “TL”, press “+”(up) or “-“(down) to select;
- Short press “SET” to confirm or to enter into sub-menu.
- Short press “PROG” to exit.
- If no command for one minute, the menu will automatically exit.
Advanced Menu
10.4 Advanced Menu Instruction
Menu
Long press “PROG” 2 seconds to enter into base menu.| Option
Press “+”(up) or “-“(down) to select;
Press “SET” to confirm.| Default/Attention
---|---|---
Travel time adjustment| Time of of gate 1
Time of of gate2
Time fine tuning of of gate 1
Time fine tuning of of gate 2| After automatic learning, if the
stroke is not ideal, it can be adjusted manually. The shorter the time under
the resistance limit, the farther the deceleration distance of the door. And
in the Hall limit, the shorter the time,
Photo Sensor| N/C; photo sensor normally is on. (Default)
N/O; photo sensor normally off.| N/O; photo sensor normally on.
Electric Lock| Electric lock normally is on. (Default)
Electric lock normally is off.| Electric lock normally on.
Reverse push lock| Reverse push lock mode off
Reverse push lock mode on
(When the electric lock is started, Ml will run for a distance in the
direction of the door to prevent the electric lock from getting stuck and
unable to be opened)| Reverse push lock mode off
Alarm Lamp| Alarm lamp normally is on. 24V power supply. (Default)
Alarm lamp normally flashes. 24V power supply.| Alarm lamp normallyis on.
24V power supply.
Limit Switch Mode| Stop block.(Default)
Hall sensor.| Stop block.
Gate Opener Secection| MS-2 (Default)| MS-2(Default)
Direction of the door| Gate Opens Inwards (Default)
Gate Opens Outwards| Gate Opens Inwards
Buzzer| The buzzer is off
The buzzer is on (When the mains is running normally, the buzzer buzzes short
and long. When the battery is in normal use, the buzzer buzzes for 6S and then
stops. When the battery power is low, the buzzer stops after 3 seconds. When
the control board runs incorrectly, the buzzer buzzes fast and long.)| The
buzzer is on
Factory Default Setting| Cancel factory default setting.
Factory default setting completes.|
Others
11.1 Maintenance
Note:
- 1. Please check whether the gate operates normally every month.
- 2. For the sake of safety, each gate is suggested to be equipped with infrared protector, and regular inspection is required as well.
- 3. Before installation and operation of the gate opener, please read all instructions carefully.
- 4. We reserve the right to change the instruction without prior notice.
11.2 Error Message
Errors that may occur when the door is operating properly
Wrong Indication | Cause of Error | Solution |
---|---|---|
Door 1 Obstructed in opening | 1.Check whether there are obstacles when |
opening door 1
2.Adjust resistance sensitivity appropriately
3.Increase deceleration distance appropriately
| Door 2 Obstructed in opening| 1.Check whether there are obstacles when
opening door 2
2.Adjust resistance sensitivity appropriately
3.Increase deceleration distance appropriately
| Door 2 is closing with difficulty| 1.Check whether there are obstacles when
door 1 is closed
2.Adjust resistance sensitivity appropriately
3.Increase deceleration distance appropriately
| Door 2 is closing with difficulty| 1.Check whether there are obstacles when
door 2 is closed
2.Adjust resistance sensitivity appropriately
3.Increase deceleration distance appropriately
| Infrared disconnect| 1.Check the infrared setting status
2.Whether there are occlusions in the infrared
| Door 1 closes before door 2| 1. Relearn your itinerary
2.Adjust the opening time interval
| The motor works for too long| 1. Check whether you have completed the
itinerary
2.Hall component damage
| No study itinerary| Re-complete the trip
11.3 Troubleshooting
Problems | Possible Reasons | Solutions |
---|---|---|
The gate cannot open or close normally, and Display does not light. | 1.The |
power is off.
2.Fuse is burned.
3.Control board power wiring with problem.| 1.Switch on the power supply.
2.Check the fuse, change the fuse if burnt.
3.Re wiring according to instructions.
The gate can open but cannot close.| 1.Photocell wiring with problem.
2.Photocell mounting with problem.
3.Photocell is blocked by objects.
4.Sensitivity of obstacle is too high.| 1.If not connect photocell, please
make sure that the 5 and 6, 5 and 7 short circuit; if connect infrared sensor,
please make sure the wiring is correct and the photocell is N.C.
2.Make sure that the photocell mounting position can be mutually aligned.
3.Remove the obstacle.
4.Reduce the sensitivity of obstacle.
Remote control doesn’t work.| 1.Battery level of the
remote control is low.
2.Remote control learning is not completed.| 1.Change the remote control
battery.
2.Re-conduct remote control learning.
Press OPEN, CLOSE button, the gate is not moving, motor has noise.| Gate
moving is not smoothly.| According to the actual situation to adjust the motor
or the gate.
Leakage switch tripped.| Power supply line short circuit or motor line short
circuit.| Check wiring.
Remote control working distance is too short.| Signal is blocked.| Connect
external receiver antenna, 1.5 meters above ground.
The gate moves to the middle position to
stop or reverse.| 1. Motor output force is not enough.
2. Sensitivity of obstacle is too high.
3. Gate meets obstacle.| 1. Check whether the transformer power is normal,
if not, change the transformer.
2. Adjust the TR2.
3. Remove the obstacle.
Read User Manual Online (PDF format)